Lighting Systems LP-21

Lighting Systems LP-21

1BHFPG

-JOFBS1FSG-ZUF DN 8BMM.PVOU-JHIU51FS'PPU /PNJOBM 4FDUJPO

8.00” (20.32cm)

2.50”

(6.35cm)

0.25”(0.64cm)

1BHFPG0.25” (0.64cm)

Module Ordering Information

3.00”

PERF(7.62cm) 3.35" (8.51cm)

Half Scale

Style

LP

Series

W

Lamps Type Length BallastOptions

 

2

 

T8

 

 

 

 

 

 

 

2 = 2 Lt Cross

T8 = T8 Lamps 4 = 4-Foot

U = Uni-voltage

Blank = No Options

 

Section

 

8 = 8-Foot

E = Emergency Pack

DS = Dual Switched

 

 

 

 

 

 

D1 = Dimming 120v

X4 = 4th through wire

 

 

 

 

 

 

D2 = Dimming 277v

 

 

Complete ordering instructions below.

Features

1.Housing: 18 gauge steel. Die-formed steel end cap withconcealed access holes for through wiring. No exposed fasteners or hardware.

2.Lamping: Two F32T8 fluorescent lamp per 4-Foot section. Provided by others.

3.Reflector: Precision die-formed specular aluminum.

4.Diffuser: Opal Acrylic.

Electrical

Ballast is universal voltage, <10% THD, .88 ballast factor, instant start. 3 con- ductor, 18 gauge wire. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting consult factory. Factory installed ballast disconnect allows the ballast to be disconnected fromand reconnected to incoming power under load without turning the entire circuit off.

Dimming: 120/277 VAC.

Emergency Battery Pack: 32 watt: 450 lumens @ 90 minutes.

Finish

Powder coated baked white enamel. Custom colors available, consult factory.

Options

Dual Switching: Order the DS option for separate row switching. DS option automatically ships with the X4 option included.

X4 Wire: Order X4 modules for remainder of the run when using dimming and/or switched emergency battery pack modules.

Emergency Circuiting: Special circuiting - consult factory.

Ordering Instructions

Individual Fixtures:

1.Order number of MODULES required.

2.Order one END SET per MODULE.

Continuous Rows:

1.Determine run length.

2.Order the appropriate number of MODULES for the complete run.

3.Order one END SET per run.

4.Order one JOINER CONNECTOR per MODULE in run minus one.

Labels

UL, cUL and I.B.E.W.

Job Information
Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #