Lighting Systems LSB-1

1BHFPG

 

 

-ZUFTQSFBEÜ-4#4PMJE*OEJSFDU-JHIU51FS'PPU /PNJOBM 4FDUJPO

Performance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CANDLEPOWER CURVE

ZONE

0

CANDLEPOWER

67

90

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

22

45

 

 

 

% EFFECTIVE CEILING CAVITY

 

 

DEG.

 

 

 

 

 

 

 

 

 

 

 

CANDELAS

 

 

 

 

 

 

REFLECTANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

370

370

370

370

370

 

 

 

80

 

 

70

 

 

50

 

 

175

369

372

377

384

385

 

 

 

% WALL REFLECTANCE

 

 

165

353

374

406

438

438

 

 

70

50

30

70

50

30

50

30

10

 

155

326

370

437

499

519

RATIO

0

85

85

85

73

73

73

50

50

50

 

135

222

323

482

627

681

2

70

64

59

60

55

51

38

35

33

 

145

280

356

466

565

598

 

1

77

74

70

66

63

60

43

42

40

 

125

172

300

529

799

859

CAVITY

3

64

56

51

54

48

44

33

30

28

 

115

109

267

635

881

948

4

58

50

43

50

43

37

29

26

23

 

105

53

571

556

579

580

 

5

53

44

37

45

38

32

26

23

20

 

95

14

106

77

57

56

ROOM

6

49

39

32

41

33

28

23

20

17

 

90

3

4

5

5

5

7

45

35

28

38

30

25

21

17

15

 

85

0

0

0

0

0

 

8

41

31

25

35

27

22

19

15

13

 

75

0

0

0

0

0

 

9

38

28

22

33

24

19

17

14

11

 

65

0

0

0

0

0

 

10

36

26

20

30

22

17

15

12

10

 

55

0

0

0

0

0

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

45

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

35

0

0

0

0

0

DISTRIBUTION

 

 

 

 

 

 

 

 

25

0

0

0

0

0

 

 

 

 

 

 

 

 

Zone

 

Lumens

% Lamp

 

% Luminaire

 

15

0

0

0

0

0

 

 

 

0-90

 

0

 

 

0.0

 

 

0.0

 

REPORT NO: LRL 300-1Q

5

0

0

0

0

0

 

 

 

 

 

 

0

0

0

0

0

0

90-180

2588

 

 

89.2

 

 

100.0

 

CAT NO: LSB14A28

 

 

 

 

 

LAMPS: 1 F28T5

 

 

 

 

 

 

0-180

2588

 

 

89.2

 

 

100.0

 

LUMENS: 2900

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

 

 

 

 

 

EFFICIENCY: 89.2%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixture Lengths & Mounting Locations

 

48"

96" (243.84cm)

 

4-Foot

8-Foot

 

 

Module

Module

 

(121.92cm)

 

 

 

4-Foot Run

4-Foot

8-Foot

8' 5-1/8" (256.86cm)

1

 

 

4' 5-1/8"

8-Foot Run

 

1

 

(134.94cm)

 

 

 

 

12-Foot Run

1

1

 

 

48"

 

96" (243.84cm)

16-Foot Run

 

2

 

(121.92cm)

 

12-Foot

 

20-Foot Run

1

2

12' 5-1/8" (378.78cm)

 

 

 

24-Foot Run

 

3

 

96" (243.84cm)

96" (243.84cm)

 

 

 

16-Foot

16' 5-1/8" (500.70cm)

 

 

 

 

 

 

 

 

96" (243.84cm)

96" (243.84cm)

48"

 

 

 

(121.92cm)

 

 

20-Foot

 

 

 

 

20' 5-1/8" (622.62cm)

 

 

 

 

 

 

 

 

96" (243.84cm)

96" (243.84cm)

96" (243.84cm)

 

 

24-Foot

 

24' 5-1/8" (744.54cm)

 

 

 

 

 

 

 

 

Cable/

Assembly

1

1

2

2

Power Feed

End Set

1

1

1

1

1

1

Mounting Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Feed End Set

Cable Assembly

Cable/Cord Assembly

Single Cable: LSBC36

Single Cable & Cord: LSBCC36

Straight Cord: LSBEC36WH (white)

 

 

 

 

 

 

 

Single Cable & 4 Wire Cord*: LSBCC36X4

 

 

 

 

 

 

 

 

 

LSBEC36AL (aluminum)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Wire Cord*: LSBEC36WHX4 (white)

*Use for dimming, switching, and emergency battery packs.

 

 

 

 

 

 

 

 

 

LSBEC36ALX4 (aluminum)

Ceiling Grid Kit

CGK

Includes both Standard 1” (2.54cm) Tee Bar Clip & Slot Tee Clip

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier LSB-1 manual 1BHFPG, Performance, Fixture Lengths & Mounting Locations, Mounting Accessories

LSB-1 specifications

Lightolier LSB-1 is a sophisticated lighting solution designed to cater to modern lighting needs with exceptional efficiency and performance. This fixture embodies a combination of aesthetic appeal and functionality, making it a popular choice in various spaces, including residential, commercial, and industrial settings.

One of the standout features of the LSB-1 is its sleek and minimalist design. It seamlessly integrates into various decor styles, providing versatility for architects and designers. The fixture is often available in a range of colors and finishes, allowing it to complement any environment effortlessly.

The LSB-1 incorporates advanced LED technology, which offers significant energy savings compared to traditional lighting solutions. LEDs have a much longer lifespan, reducing the frequency of replacements and minimizing maintenance costs. This feature makes the LSB-1 a highly sustainable option, aligning with the contemporary demand for eco-friendly products.

Brightness control is another impressive aspect of the LSB-1. The fixture is compatible with dimming capabilities, allowing users to adjust the light intensity to suit different moods and activities. This flexibility enhances the overall ambiance of a space, whether it's for productivity during work hours or creating a cozy environment for relaxation.

In addition to its aesthetic and energy-efficient features, the LSB-1 also employs advanced optical technology. The fixture's lenses are designed to distribute light evenly, reducing glare and creating a more comfortable visual experience. This is particularly beneficial in work environments where prolonged exposure to direct light can cause eye strain.

The durability of the Lightolier LSB-1 is another key characteristic. Constructed from high-quality materials, it is resistant to impacts and environmental factors, making it suitable for both indoor and outdoor applications. This robustness ensures that it can withstand the rigors of daily use while maintaining its performance and appearance.

Installation of the LSB-1 is straightforward, thanks to its user-friendly design. The fixture is equipped with versatile mounting options, simplifying the process for electricians and DIY enthusiasts alike. This ease of installation contributes to its appeal, as it saves time and labor costs.

In summary, the Lightolier LSB-1 is a cutting-edge lighting fixture that combines modern design with advanced technology. Its energy efficiency, dimmable features, optical performance, durability, and ease of installation make it a prime choice for various applications. The LSB-1 not only illuminates spaces beautifully but also supports sustainability and user comfort, making it an intelligent investment for anyone seeking quality lighting solutions.