Lightolier LSB-14 Performance, Fixture Lengths & Mounting Locations, Mounting Accessories, Foot

Models: LSB-14

1 2
Download 2 pages 59.04 Kb
Page 2
Image 2
Lighting Systems LSB-14

 

 

 

 

 

 

 

 

Lighting Systems LSB-14

1BHFPG

 

 

-ZUFTQSFBEÜ-4#3BEJBM-PVWFS-JHIU51FS'PPU /PNJOBM 4FDUJPO

Performance

 

 

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

CANDLEPOWER CURVE

 

 

CANDLEPOWER

 

 

 

 

 

 

ZONE

0

22

45

67

90

 

 

% EFFECTIVE CEILING CAVITY

 

 

DEG.

 

CANDELAS

 

 

 

 

 

REFLECTANCE

 

 

 

 

 

 

 

 

 

 

80

 

 

70

 

 

50

 

 

180

847

847

847

847

847

 

 

 

 

 

 

 

 

175

848

847

848

848

847

 

 

WALL REFLECTANCE

 

 

 

165

835

837

836

835

825

 

70

50

30

70

50

30

50

30

10

 

155

797

800

811

826

825

0

84

84

84

75

75

75

57

57

57

 

145

719

740

778

819

823

1

77

73

70

68

65

63

50

49

47

 

135

599

641

726

821

834

2

70

65

60

62

58

54

45

42

40

 

125

485

546

722

889

885

3

64

57

51

57

51

46

40

37

34

 

115

325

436

693

855

908

4

59

51

45

52

45

40

36

32

29

 

105

174

337

576

646

649

5

54

45

39

48

41

35

32

28

25

 

95

45

128

88

80

65

6

50

41

34

44

37

31

29

25

22

 

90

0

0

0

0

0

7

46

36

30

41

33

27

26

22

19

 

85

17

19

22

25

28

8

42

33

27

38

30

24

24

20

17

 

75

40

44

48

57

89

9

39

30

24

35

27

22

22

18

15

 

65

66

71

81

141

308

10

37

27

22

33

25

20

20

16

14

 

55

112

115

135

226

349

20% FLOOR CAVITY REFLECTANCE

 

 

45

144

156

194

279

341

DISTRIBUTION

 

 

 

 

 

 

 

 

35

252

271

323

394

444

 

 

 

 

 

 

 

 

Zone

 

Lumens

% Lamp

 

% Luminaire

 

25

392

406

452

514

546

 

 

 

0-90

 

1167

 

 

20.1

 

 

24.3

 

 

15

516

526

551

589

598

 

 

 

 

 

 

REPORT NO: LRL 300-1F

5

618

619

627

630

632

90-180

3643

 

 

62.8

 

 

75.7

 

0

633

633

633

633

633

0-180

4810

 

 

82.9

 

 

100.0

 

CAT NO: LSB24D28

 

 

 

 

 

LAMPS: 2 F28T5

 

LUMENS: 2900

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

EFFICIENCY: 82.9%

 

Fixture Lengths & Mounting Locations

 

 

 

 

 

48"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96" (243.84cm)

 

 

 

 

 

 

4-Foot

 

 

 

 

(121.92cm)

 

 

8-Foot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-Foot Run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4' 5-1/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8' 5-1/8" (256.86cm)

 

 

 

 

 

 

(134.94cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-Foot Run

 

 

 

 

 

 

 

 

 

 

96" (243.84cm)

 

 

 

 

 

 

 

 

48"

 

 

 

 

 

 

 

 

 

12-Foot Run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(121.92cm)

 

 

 

 

16-Foot Run

12-Foot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20-Foot Run

 

 

 

 

 

 

 

 

 

 

 

12' 5-1/8" (378.78cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24-Foot Run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-Foot

8-Foot

Module

Module

1

 

 

1

1

1

 

2

1

2

 

3

Cable/

Assembly

1

1

2

2

Power Feed

End Set

1

1

1

1

1

1

96" (243.84cm)

96" (243.84cm)

 

16-Foot

16' 5-1/8" (500.70cm)

 

 

 

96" (243.84cm)

96" (243.84cm)

48"

(121.92cm)

20-Foot

 

20' 5-1/8" (622.62cm)

 

 

 

96" (243.84cm)

96" (243.84cm)

96" (243.84cm)

24-Foot

24' 5-1/8" (744.54cm)

 

 

 

Mounting Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Feed End Set

Cable Assembly

Cable/Cord Assembly

Single Cable: LSBC36

Single Cable & Cord: LSBCC36

Straight Cord: LSBEC36WH (white)

 

 

 

 

 

 

 

Single Cable & 4 Wire Cord*: LSBCC36X4

 

 

 

 

 

 

 

 

 

 

LSBEC36AL (aluminum)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Wire Cord*: LSBEC36WHX4 (white)

*Use for dimming, switching, and emergency battery packs.

 

 

 

 

 

 

 

 

 

 

LSBEC36ALX4 (aluminum)

Ceiling Grid Kit

CGK

Includes both Standard 1” (2.54cm) Tee Bar Clip & Slot Tee Clip

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier LSB-14 Performance, Fixture Lengths & Mounting Locations, Mounting Accessories, FootRun, Cable Assembly, Type