Lightolier manual Lighting Systems LSBW-9, Ordering Information, Features, Electrical, Finish

Models: LSBW-9

1 2
Download 2 pages 37.68 Kb
Page 1
Image 1
Lighting Systems LSBW-9

Lighting Systems LSBW-9

1BHFPG

-ZUFTQSFBEÜ-4#1BSBCPMJD8BMM.PVOU-JHIU51FS'PPU /PNJOBM 4FDUJPO

11-3/8" (28.89cm)

8-1/2" (21.59cm)

1

2

4

3-1/2" (8.89cm)

3

1-3/4"

(4.45cm)

2-5/8"

(6.67cm)

Ordering Information

TypeLampsLength

LSBW

 

1

 

 

 

1 = 1-Lamp T5

4 = 4-Foot

 

 

 

 

8 = 8-Foot

Complete ordering instructions below.

ShieldingBallastVoltageFinish

C

C = Parabolic Louver 28 = 28W T51 = 120 Volt

AL = Aluminum

54 = 54W T52 = 277 VoltWH = White

5E = 54W T5 Emergency Pack

 

 

2E = 28W T5 Emergency Pack

 

 

5D = 54W T5 Dimming

 

 

Features

1.Housing: Extruded aluminum. Die-cast end cap mechanically attached with no exposed fasteners or hardware.

2.Lamping: One T5, 28 or 54 watt (as specified) fluorescent lamp per 4-foot nominal section. Provided by others.

3.Reflector: Precision die-formed, semi-specular aluminum.

4.Shielding: Parabolic louver, low-iredescent, semi-specular anodized aluminum 41” (104.14cm) shielding lengthwise, blades are 1-1/3” (3.39cm) high and 2” (5.08cm) O.C. Louver frame is extruded aluminum and finished to match housing.

Electrical

Ballast - <10% T.H.D., .98 ballast factor, pre-heat start. 18 gauge wire. Color- coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off.

Dimming - 120/277 VAC, 1% dimming level.

Emergency Battery Pack - 28 Watt: 520 Lumens @ 90 min. 54 Watt: 700 Lumens @ 90 min. 4 wire feed required.

Mountings

Dual-screw, draw-tight connector to create hairline seam between joiner modules.

Finish

Powder coated baked white or aluminum finish.

Custom colors available, consult factory.

Labels

UL, cUL and I.B.E.W.

Ordering Instructions

Individual Fixtures:

1.Order number of MODULES required.

2.Order one END SET per MODULE.

Continuous Rows:

1.Determine run length.

2.Order the appropriate number of MODULES to complete the run.

3.Order one END SET per run.

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.