Mini-Beam HP 2'x4' Recessed Fluorescent MBS2GHP228WA

Page 2 of 2

Direct/Indirect, Static, 2 Lamp, Linear T5, 28 Watt

Model No. MBS2GHP228120WA

LER = FP - 75.4 IW - 55.4 BF - 0.93 Comparative yearly lighting energy cost per

1000 lumens = $3.18 Report Number: G2005263

Catalog Number: MBS2GHP228120WA

Lamp: FP28/835

Luminaire: MBS with prismatic lens

Ballast: WA Energy Smart

Report is based on 2750 lumens per lamp.

Efficiency: 90.7%

 

 

 

 

 

 

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

0-Deg.

 

90-Deg.

 

Spacing Criteria:

 

1.3

 

1.4

 

Shielding Angles:

 

90

 

 

90

 

Plane:

 

 

 

0-Deg.

 

90-Deg.

 

Luminous Length:

46.920

 

22.920

 

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

98

93

89

87

84

81

84

81

79

2

89

81

74

76

70

66

73

68

65

3

80

70

62

66

60

55

64

58

54

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1458

1458

1458

 

5

1446

1471

1490

141

15

1394

1504

1565

422

25

1299

1471

1522

665

35

1164

1350

1376

821

45

989

1160

1245

882

55

776

933

1047

829

65

522

673

779

660

75

261

446

530

441

85

51

131

142

128

90

0

0

0

 

 

 

 

 

 

60'

56'

Fixture: MBS2GHP228120WA

Quantity: 6 Rows of 7 Fixtures

Efficiency: 90.7%

Room Size: 60' x 56' x 9'

Reflectance: 80/50/20

Lumens: T5 Lamp: 2750

Ballast Factor: 0.93

Average Maint. fc: 52.4

Watts/Square Foot: 0.69

4

73

62

54

58

52

46

56

50

46

5

67

55

47

52

45

40

50

44

39

6

62

49

41

47

40

35

45

39

34

7

57

45

36

43

35

30

41

35

30

8

53

41

33

39

32

27

38

31

27

9

50

37

30

36

29

24

35

29

24

10

47

34

27

33

26

22

32

26

22

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2000.

2345.

2517.

55

1934.

2325.

2610.

65

1766.

2277.

2635.

75

1442.

2464.

2928.

85

837.

2149.

2329.

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1229

22.3

24.6

00-040

2050

37.3

41.1

00-060

3760

68.4

75.4

00-090

4990

90.7

100.0

90-180

0000

0.0

000.0

00-180

4990

90.7

100.0

 

 

HOURS

 

INPUT

COST/KWH

BURNED

YEARLY

WATT

.10¢/1000

PER YEAR

COST

148

.000

6570

$97.24

56

.000

6570

$36.19

MBS Savings per fixture

$60.45

 

 

 

 

MBS vs Typical troffer with Magnetic ballast

and 3 T12 34 watt lamps.

Ordering Information

Explanation of Catalog Number. Example: MBS2GHP228120WA

S

 

2

 

G

 

HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

WA

 

 

 

 

 

 

 

Mini-Beam

Body Style:

Fixture

Ceiling Type:

High

Direct/Indirect

S = Static

Width

Fits both

Performance

 

Recessed

 

 

Standard Grid

Prismatic

 

 

 

 

and

Lens

 

MB

Standard Mini-Beam

 

Slot Grid

 

 

 

 

 

 

 

 

 

 

 

M3

For NYC Code – Local 3 Manufactured

 

 

Options/Accessories

Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF.

Electrical/Wiring Options: Consult factory.

Lamp

Quantity

1=1 Lamp

2=2 Lamp

Lamp Quantity:

(By others)

28 = 28 Watt T5

Voltage:

 

Options:

120 or 277

 

Add appropriate

UNV=120-277

 

suffix to catalog

Ballast Type:

no, ie: (GLR)

Energy Smart

 

WA = Linear T5 Instant

 

Start Less than

 

10 THD 56 Input

 

Watts 0.93

 

Ballast Factor

 

Other Ballast Options:

 

<20THD <10THD

1-2 Lamp 28W Elec. T5

PI

1-2 Lamp 28W Elec. T5

PG ††

†Instant Start (120V or 277V only) ††Program Rapid Start (UNV only)

Specifications

Performance: In an installation of 2 lamps 28W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than 0.93. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.4%.

Materials: Housing is die-formed 20 gauge steel.

Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–Prismatic virgin acrylic lens.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2005 a Genlyte company

Section 5/Folio M20-26

Page 2
Image 2
Lightolier MBS2GHP228WA Page 2 of, Ordering Information, Options/Accessories, Specifications, Hours, Input, Cost/Kwh, Watt