MD*Coffer 2' x 4' Recessed or Surface MDCGWSVA2SB4SB
Page 4 of 4 | |
| Indirect Ambient Light with Perforated Mesh Shield |
ORDERING INFORMATION
Explanation of Catalog Number. Example: MDCGWSVA2SB4SB120SW
| MDC |
|
|
| G |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MD*C |
|
| Ceiling |
|
| Louver/ |
| Louver | ||||||||
| Indirect/ |
|
| Type: |
|
| Lens Frame: |
| Overlay/Lens: | ||||||||
| Direct |
|
| Same Unit | WS = | White Louver | VA = Virgin Acrylic | ||||||||||
| Recessed or |
|
| May Be Used | RF = Regressed |
| .095" Nominal | ||||||||||
| Surface, |
| For: Grid |
|
| Floating Extruded |
| Thickness | |||||||||
|
|
| Or: Surface |
|
| Aluminum Door | VI | Overlay | |||||||||
| Patient Light |
|
| Mounted |
|
| Frame | (standard) | |||||||||
with Perforated |
|
|
|
|
|
|
|
|
|
| = .125" Thick | ||||||
| Mesh Shield |
|
|
|
|
|
|
|
|
|
|
| Pattern 12 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Acrylic Lens. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
|
|
|
|
|
|
Lamp |
|
|
| Lamp |
| Voltage: | Options: | |||||
|
|
| Quantity |
| 120 or 277 | Add appropriate | ||||||
Quantity: |
|
|
|
| ||||||||
|
| 3 = 3 Lamp |
|
|
| Suffix to Catalog | ||||||
(Ambient/ |
|
|
|
|
| |||||||
|
| 4 = 4 Lamp |
|
|
| No. i.e. (GLR) | ||||||
Reading) |
|
|
|
|
| |||||||
2 Lamps |
|
|
|
|
|
|
|
|
|
| ||
(Total) | Ballast Type: |
|
| Ballast Type: |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||
|
|
| (Ambient Reading) |
|
| (Examination) |
|
|
|
| ||
|
|
|
| <20THD | <10THD | <20THD | <10THD |
|
| |||
| SB* | IB* |
| X3* | I3* |
|
| |||||
| (40 Watt) |
|
|
|
| SB* | IB* |
|
| |||
| – | PR** |
| – | PR** |
|
| |||||
| (40 Watt) |
|
|
|
| (40 Watt) | PB | – |
|
| ||
|
|
|
|
| LOL Dimming TT5 |
|
| |||||
| LOL Dimming TT5 | PB | – |
|
|
| ||||||
|
|
|
|
|
|
|
|
*Instant Start Standard | *Instant Start Standard | |
**Program Start | ||
**Program Start | ||
NOTE: | ||
NOTE: | ||
For TT5 UNV, you must use IB Ballast | ||
For TT5 UNV, you must use IB Ballast | ||
Code | ||
Code | ||
|
Options/Accessories
Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Catalog Number: ACP.
Drywall Kit: Order Catalog Number: FK92X4. Request Folio
Electronic Sequential Switch (Low Voltage): Switch factory mounted in fix- ture for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW.
Individual Switching (Low Voltage): Switches mounted to patient's bed for use with manufacturer's control system (such as
Suffix: DP.
9/7 Watt Night Light: Suffix: PL (Lamp not included).
Fusing: Internal
Radio Interference Filter: To order one RIF per fixture; Suffix: R. To order one RIF
per ballast; Suffix: B.
Germ Shield. Order Catalog Number: MD4CLGS24.
Electrical/Wiring Options: Consult factory.
Specifications:
Materials: Chassis parts are
Reading light – low iridescence anodized 95% reflective,
Ambient light – flat white acrylic contoured steel reflector and perforated steel mesh shield with white acrylic overlay.
Finish: Cavity (examination/reading/ambient lights) — flat white acrylic interior, minimum reflectance 86%. Phosphate undercoating. Chassis exterior — post painted white baked polyester powder. Louver (examination light) W=flat white baked enamel 36 cell louver with a virgin acrylic overlay to enclose all lamps. VA=.095" nominal thickness prismatic virgin acrylic overlay. VI=.125" nominal thickness, pattern 12 acrylic lens.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Specifications (continued):
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
| Job Information | Type: |
|
|
|
| |||
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)