Lightolier PLA2G12LS232 Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: PLA2G12LS232

1 2
Download 2 pages 389 b
Page 2
Image 2
Page 2 of 2
Section 2/Folio G50-62 Rev. A

 

Paralyte 2448 PLA2G12LS232

Page 2 of 2

2' x 4' Recessed Fluorescent, 3-1/8" Deep, 12 Cell Parabolic Louver

 

Static and Air Return 2 Lamp, T8 or T12

Photometry

Model No. PLA2G12LS232120SO

G91070

PLA2G12LS232120SO

LER=FP-67.5 IW - 58 BF - 0.87

Comparative yearly lighting energy cost per 1000 lumens=$3.56

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

RF

 

 

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

RC

 

 

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

RW

 

70

 

 

50

 

30

 

50

30

 

10

 

50

 

30

10

 

1

 

87

 

 

84

 

81

 

79

77

 

75

 

76

 

74

73

ratio

2

 

80

 

 

74

 

70

 

70

66

 

63

 

68

 

65

62

3

 

73

 

 

66

 

60

 

62

58

 

54

 

60

 

56

53

cavity

4

 

67

 

 

58

 

52

 

55

50

 

46

 

54

 

49

45

5

 

62

 

 

52

 

45

 

50

44

 

40

 

48

 

43

39

 

 

 

 

 

 

 

 

 

room

6

 

57

 

 

47

 

40

 

45

39

 

35

 

43

 

38

34

7

 

53

 

 

42

 

35

 

40

35

 

30

 

39

 

34

30

 

8

 

49

 

 

38

 

32

 

37

31

 

27

 

36

 

31

27

 

9

 

46

 

 

35

 

29

 

34

28

 

24

 

33

 

28

24

 

10

 

43

 

 

32

 

26

 

31

26

 

22

 

30

 

25

22

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

W

 

 

L

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

20

 

 

20

 

 

 

76

72

72

83

 

 

 

73

66

66

 

73

20

 

 

30

 

 

 

79

75

73

73

 

 

 

76

69

66

 

69

20

 

 

40

 

 

 

82

78

76

75

 

 

 

79

72

69

 

68

20

 

 

60

 

 

 

83

80

78

77

 

 

 

81

75

72

 

71

30

 

 

20

 

 

 

80

76

72

79

 

 

 

78

71

68

 

73

30

 

 

30

 

 

 

83

79

73

70

 

 

 

81

74

67

 

68

30

 

 

40

 

 

 

84

81

76

72

 

 

 

82

76

70

 

67

30

 

 

60

 

 

 

86

82

78

75

 

 

 

84

78

73

 

70

30

 

 

80

 

 

lengthwise

87

83

80

77

 

 

crosswise

85

80

75

 

72

40

 

 

40

 

 

86

83

78

72

 

 

84

79

73

 

68

40

 

 

20

 

 

 

83

79

75

78

 

 

 

80

75

72

 

73

40

 

 

30

 

 

 

85

81

75

71

 

 

 

82

77

71

 

69

40

 

 

60

 

 

luminaries

87

84

80

75

 

 

luminaries

85

81

75

 

71

40

 

 

80

 

 

88

85

81

77

 

 

86

82

77

 

73

 

 

 

 

 

 

 

 

 

40

 

 

100

 

 

 

88

85

82

78

 

 

 

86

82

79

 

75

60

 

 

30

 

 

 

85

83

78

73

 

 

 

83

78

73

 

72

60

 

 

40

 

 

 

87

84

80

74

 

 

 

85

80

75

 

71

60

 

 

60

 

 

 

88

85

81

76

 

 

 

86

82

77

 

73

 

 

 

 

 

 

 

 

60

 

 

80

 

 

 

89

86

83

78

 

 

 

87

83

79

 

75

60

 

 

100

 

 

 

89

86

83

79

 

 

 

87

83

80

 

76

100

 

 

40

 

 

 

87

84

81

77

 

 

 

85

80

77

 

72

100

 

 

60

 

 

 

88

85

83

79

 

 

 

86

82

79

 

74

100

 

 

80

 

 

 

88

86

84

80

 

 

 

87

84

80

 

77

100

 

 

100

 

 

 

89

87

84

81

 

 

 

87

84

82

 

78

Ordering Information

Explanation of Catalog Number. Example: PLA2G12LS232120SOGLR

PL

 

A

 

 

 

 

 

Paralyte

 

Body Style:

2448:

A= Air Handling

3-1/8" Deep

 

/Static

Parabolic

Precision

Contoured

Pre-anodized

Aluminum

Louver

 

2

 

G

 

 

12

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixture

 

Ceiling Type:

Number of

 

 

 

 

Ballast Cover

Lamp

 

Lamp/

Voltage:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options:

 

Width

G=Grid (lay-in T bar)

Cells

 

 

 

S=Single V Reflector

Quantity:

Fixture Length:

120 or 277

 

 

 

Add appropriate suf-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 or 4 Lamps

 

32=T8

 

 

 

 

 

 

fix to catalog no.,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34=T12

 

 

 

 

 

 

 

 

ie: (GLR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Nominal 48")

 

 

 

 

Ballast Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver Finish:

 

 

 

 

 

 

1–2 Lamp Mag. T12

LE

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

<20THD

<10THD

 

 

 

 

 

 

 

 

 

= Low Iridescence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1–2 Lamp Elec. T8

SO*

HI*

 

 

 

 

 

 

 

 

 

 

Semi-Specular (standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W = White Paint

 

 

 

 

 

 

2–2 Lamp Elec. T8

SO*

HI*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1–4 Lamp Elec. T8

O4*

H4*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOL T8 Dimming

PS*

 

Other dimming options. Consult factory.

Options & Accessories

Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long),

Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter, concealed in fixture channel. Operates one fluorescent lamp at reduced light output for 90 minutes. Suffix: EM.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz.

One per fixture. Suffix: R. One per ballast. Suffix: B.

Electrical Options: Special wiring, fusing or dimming ballasts and installed lamps are available, consult your Lightolier representative or factory.

T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC. 2 each end is required.

Specifications

Performance: In an installation of 2 lamp 32W Iuminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall not be less than 84. To prevent glare the VCP shall not be less than 86 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1347 foot-Iamberts. To control veiling reflections, luminaire output in the 3C°-90° zone shall not be less than 72.1%.

Specifications (continued)

Air Return: Designed to provide optimum air return. Air is returned through the lamp compartment for all ceiling systems and direct to plenum through slots in slot grid and narrow grid ceiling systems.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for rigidity with all edges turned up for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal).

Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate undercoating. Chassis exterior–black baked polyester enamel.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3” of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier PLA2G12LS232 dimensions Page 2 of, Photometry, Ordering Information, Options & Accessories, Specifications, Type