Section 2/Folio G50-55 Rev. A

 

Paralyte 2424 PLA2G9LP32U

Page 2 of 2

2' x 2' Recessed Fluorescent, 3-1/8" Deep, 9 Cell Parabolic Louver

 

Static and Air Return 3 Lamp, T8, 1-5/8" U Lamp

Photometry

Model No. PLA2G9LP32U120O3

ITL33754

LIGHTOLIER

PLA2G9LP32U120O3

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

LER = FP - 64.6

IW - 85.0 BF - 0.88

 

 

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $3.79

 

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

RF

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

RC

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

RW

 

70

50

 

30

 

50

30

 

10

 

50

 

30

10

 

1

 

81

78

 

76

 

74

72

 

70

 

71

 

70

68

ratio

2

 

76

71

 

67

 

67

64

 

62

 

65

 

62

60

3

 

70

64

 

69

 

61

67

 

54

 

69

 

56

53

 

 

 

 

 

 

 

cavity

4

 

65

57

 

52

 

55

61

 

47

 

53

 

50

47

5

 

60

51

 

46

 

49

45

 

41

 

48

 

44

41

room

6

 

55

46

 

41

 

44

40

 

36

 

43

 

39

36

7

 

51

42

 

36

 

40

35

 

31

 

39

 

34

31

 

8

 

47

37

 

31

 

36

31

 

27

 

36

 

30

27

 

9

 

43

33

 

28

 

32

27

 

23

 

31

 

27

23

 

10

 

40

30

 

25

 

29

24

 

21

 

28

 

24

21

visual comfort probability (rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

W

 

 

L

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

20

 

 

20

 

 

65

59

56

68

 

 

 

70

65

62

 

63

20

 

 

30

 

 

68

62

55

54

 

 

 

73

68

63

 

60

20

 

 

40

 

 

71

65

60

56

 

 

 

75

70

66

 

62

20

 

 

60

 

 

72

68

63

59

 

 

 

76

72

69

 

65

30

 

 

20

 

 

71

64

59

65

 

 

 

75

68

63

 

62

30

 

 

30

 

 

73

67

58

53

 

 

 

77

71

63

 

59

30

 

 

40

 

 

75

69

62

55

 

 

 

78

72

67

 

61

 

 

 

 

 

 

 

 

30

 

 

60

 

lengthwise

76

71

64

58

 

 

crosswise

79

74

69

 

64

30

 

 

80

 

77

73

67

61

 

 

80

75

71

 

66

40

 

 

20

 

 

74

67

63

66

 

 

 

78

73

66

 

63

40

 

 

30

 

 

75

70

62

55

 

 

 

79

74

67

 

60

40

 

 

40

 

luminaries

77

72

65

57

 

 

luminaries

80

75

69

 

62

40

 

 

60

 

78

73

67

60

 

 

80

76

71

 

64

40

 

 

80

 

 

79

75

69

62

 

 

 

81

77

73

 

66

40

 

 

100

 

 

80

76

71

65

 

 

 

82

78

74

 

68

60

 

 

30

 

 

77

72

66

59

 

 

 

80

76

70

 

62

60

 

 

40

 

 

79

74

68

60

 

 

 

81

77

72

 

64

60

 

 

60

 

 

79

75

70

62

 

 

 

82

78

73

 

65

60

 

 

80

 

 

80

76

71

65

 

 

 

82

78

74

 

68

60

 

 

100

 

 

80

77

73

66

 

 

 

82

79

76

 

69

100

 

 

40

 

 

80

76

71

64

 

 

 

83

79

74

 

67

100

 

 

60

 

 

81

77

73

66

 

 

 

83

79

75

 

69

100

 

 

80

 

 

81

78

74

68

 

 

 

83

80

77

 

71

100

 

 

100

 

 

82

78

75

69

 

 

 

84

80

77

 

72

Ordering Information

Explanation of Catalog Number. Example: PLA2G9LP32U120O3GLR

PL

A

2

G

9

P

3

2U

 

 

 

 

 

 

 

 

Ballast Cover:

 

 

 

Paralyte

Body Style:

Fixture

Ceiling Type:

Number of

 

Lamp

Lamp/

2424:

A= Air Handling

Width

G=Grid (lay-in T-bar)

Cells

 

P=Dual V Reflector

Quantity

Fixture Length:

3-1/8" Deep

/Static

 

 

 

 

 

 

 

 

2U= T8, 1-5/8" U

 

 

 

 

 

 

 

 

Parabolic

 

 

 

 

 

Louver Finish:

 

 

Lamp

Precision

 

 

 

 

L

 

 

(Nominal 24")

 

 

 

 

= Low

 

 

Contoured Pre-

 

 

 

 

 

 

 

anodized

Iridescence

Semi-specular

Aluminum

(standard)

Louver

W = White Paint

 

Voltage:

 

 

 

Options:

120 or 277

 

Add appropriate

 

 

 

suffix to catalog

 

Ballast Type:

<10THD

 

 

<20THD

1 & 2 Lamp Elec. T8

 

SO*

HI*

1–3 Lamp Elec. T8

 

O3*

H3*

LOL T8 Dimming

 

PS*

*Instant Start Standard

Other dimming options. Consult factory.

Options & Accessories

Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long),

Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter, concealed in fixture channel. Operates one fluorescent lamp at reduced light output for 90 minutes. Suffix: EM.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz.

One per fixture. Suffix: R. One per ballast. Suffix: B.

Electrical Options: Special wiring, fusing or dimming ballasts and installed lamps are available, consult your Lightolier representative or factory.

T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC. 2 each end is required.

Specifications

Performance: In an installation of 3 lamp, 31W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than 78. To prevent glare the VCP shall not be less than 79 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1078 footlamberts. To control veiling reflections, luminaire output in the 30° - 90° zone shall not be less than 67.3%.

Air Return: Designed to provide optimum air return. Air is returned through the

Specifications (continued)

lamp compartment for all ceiling systems and direct to plenum through slots in slot grid and narrow grid ceiling systems.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for rigidity with all edges turned up for safe handling. Louver is pre-anodized aluminum (Coilzak or equal). rails hemmed over and housing ends turned-in for safe handling.

Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate undercoating. Chassis exterior–black baked polyester enamel.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3” of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier PLA2G9LP32U dimensions Photometry, Ordering Information, Options & Accessories, Specifications

PLA2G9LP32U specifications

The Lightolier PLA2G9LP32U is a versatile and efficient lighting solution designed for both residential and commercial spaces. This product combines modern aesthetics with advanced technology, making it a popular choice for architects, electricians, and homeowners alike.

One of the standout features of the PLA2G9LP32U is its exceptional energy efficiency. Utilizing LED technology, this lighting fixture consumes significantly less electricity compared to traditional incandescent or fluorescent options. This not only reduces energy bills but also contributes to a lower carbon footprint, aligning with the growing demand for sustainable lighting solutions.

The Lightolier PLA2G9LP32U is equipped with a high lumen output, providing bright, uniform illumination that is perfect for task lighting, accent lighting, or ambient lighting. With a color temperature of 3000K, it emits a warm white light that is inviting and comfortable, making it ideal for living spaces as well as commercial applications.

One of the key technologies integrated into the PLA2G9LP32U is its dimmable capability. This feature allows users to easily adjust the brightness according to their mood or the specific needs of the environment. Compatible with a wide range of dimmers, this flexibility makes it an excellent choice for multifunctional spaces.

The fixture also boasts a sleek, modern design that complements various decor styles. Its low-profile design allows for seamless integration into ceilings, while the high-quality materials ensure durability and longevity. With a lifespan of up to 50,000 hours, users can expect minimal maintenance and fewer replacements, further contributing to cost savings over time.

Another notable characteristic of the PLA2G9LP32U is its easy installation process. Designed with user-friendliness in mind, it comes with clear instructions that make it accessible for both professional electricians and DIY enthusiasts. This ease of installation helps reduce labor costs and time, making it an attractive option for a wide range of applications.

In summary, the Lightolier PLA2G9LP32U is a cutting-edge lighting solution that combines energy efficiency, versatile brightness options, stylish design, and easy installation, making it the ideal choice for any contemporary space. Whether enhancing a cozy home setting or illuminating a professional workspace, this fixture stands out as a reliable option that meets modern lighting needs.