Lightolier PRA2GRFVA3FT Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: PRA2GRFVA2FT PRA2GRFVA3FT

1 2
Download 2 pages 24.54 Kb
Page 2
Image 2
Page 2 of 2
Section 1A/Folio E20-34

 

PRISMALYTE plus PRA2GRFVA3FT or 2FT

Page 2 of 2

2'x2' RECESSED FLUORESCENT, FLOATING LENS FRAME WITH BLACK REVEAL

 

STATIC OR AIR SUPPLY/RETURN, 2 OR 3 LAMP, TWIN TUBE T5

PHOTOMETRY

MODEL NO. PRA2GRFVA3FT

 

 

 

Luminaire Efficacy Rating

 

 

 

LER-42.7 Watts-98.0 BF-0.88

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

RF

 

 

 

20

 

 

 

 

 

20

 

 

 

 

20

 

 

 

RC

 

 

 

80

 

 

 

 

 

50

 

 

 

 

30

 

 

 

RW

 

70

 

50

 

 

30

 

50

30

10

 

50

30

10

 

 

1

 

83

 

80

 

 

77

 

75

73

71

 

72

70

69

 

ratio

2

 

76

 

71

 

 

66

 

67

63

60

 

64

61

59

 

3

 

70

 

63

 

 

58

 

60

55

52

 

58

54

51

 

cavity

4

 

65

 

57

 

 

51

 

54

49

45

 

52

48

44

 

5

 

60

 

51

 

 

45

 

49

44

40

 

47

43

39

 

room

6

 

56

 

46

 

 

40

 

44

39

35

 

43

38

35

 

7

 

52

 

42

 

 

36

 

41

35

31

 

39

35

31

 

 

8

 

48

 

39

 

 

33

 

37

32

28

 

36

32

28

 

 

9

 

45

 

36

 

 

30

 

34

29

26

 

34

29

26

 

 

10

 

43

 

33

 

 

27

 

32

27

23

 

31

27

23

 

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

room size

 

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

W

 

 

L

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

16.0

 

20

 

 

20

 

 

 

44

47

53

60

 

 

 

42

46

51

58

 

20

 

 

30

 

 

 

37

40

44

49

 

 

 

34

38

42

47

 

20

 

 

40

 

 

 

34

36

40

43

 

 

 

31

33

37

41

 

20

 

 

60

 

 

 

31

33

35

39

 

 

 

28

30

32

36

 

30

 

 

20

 

 

 

45

49

53

58

 

 

 

44

48

51

57

 

30

 

 

30

 

 

 

38

41

44

48

 

 

 

35

39

42

46

 

30

 

 

40

 

 

 

34

36

39

42

 

 

 

31

34

37

40

 

30

 

 

60

 

 

 

31

33

34

37

 

 

 

28

30

31

35

 

30

 

 

80

 

lengthwise

 

31

32

32

34

 

 

crosswise

27

29

29

32

 

40

 

 

40

 

 

35

37

40

42

 

 

32

35

38

40

 

40

 

 

20

 

 

 

47

51

54

58

 

 

 

46

50

53

58

 

40

 

 

30

 

 

 

39

42

45

49

 

 

 

37

41

44

47

 

40

 

 

60

 

luminaries

 

32

34

34

37

 

 

luminaries

29

31

32

35

 

40

 

 

80

 

 

31

32

32

34

 

 

28

29

29

32

 

40

 

 

100

 

 

 

32

32

31

32

 

 

 

29

29

28

30

 

60

 

 

30

 

 

 

40

44

46

50

 

 

 

39

43

45

49

 

60

 

 

40

 

 

 

36

38

40

43

 

 

 

34

36

38

42

 

60

 

 

60

 

 

 

33

34

34

37

 

 

 

30

32

32

35

 

 

 

 

 

 

 

 

 

60

 

 

80

 

 

 

32

32

32

34

 

 

 

29

30

29

32

 

60

 

 

100

 

 

 

32

32

30

32

 

 

 

29

29

28

30

 

100

 

 

40

 

 

 

39

41

42

45

 

 

 

38

40

41

45

 

100

 

 

60

 

 

 

36

37

36

39

 

 

 

34

35

35

38

 

100

 

 

80

 

 

 

35

35

33

35

 

 

 

32

32

31

34

 

100

 

 

100

 

 

 

35

34

32

33

 

 

 

32

31

29

30

 

ORDERING INFORMATION

Explanation of Catalog Number. Example: PRA2GRFVA3FT120X3RF

PR

2

 

 

 

RF

 

VA

 

 

 

FT

BODY STYLE:

A=Air Handling

S=Static

PRISMALYTE plus:

Floating

Lens Frame

Recessed

Fluorescent

Troffer

 

CEILING TYPE:

LENS/SHIELDING

 

 

G= Grid

TYPE:

 

 

(lay-in T bar)

VA=Virgin acrylic

 

 

T=Slot grid or

(standard), see

 

 

two-directional

options and

 

 

concealed T

LENS FRAME: consult factory

LAMP

FIXTURE

WIDTH

see options)

RF=1/2" regressed

QUANTITY

 

 

floating aluminum

2=2 Lamp

 

 

frame with 7/16"

3=3 Lamp

 

 

black reveal four

 

 

 

sides.

 

 

 

 

 

 

 

 

 

 

 

 

LAMP TYPE/

 

 

OPTIONS:

FIXTURE LENGTH:

 

 

 

 

Add appropriate

Twin Tube T5

 

VOLTAGE:

 

 

 

suffix to catalog no.,

(Nominal 24")

 

120 or 277

 

 

 

 

ie: (RF)

 

 

 

 

BALLAST TYPE:

 

 

 

 

<10THD

 

 

 

 

 

<20THD

 

 

1 &

2 Lamp Elec. TT5

 

SB*

IB*

 

 

(40 Watt)

 

X3*

I3*

 

 

1-3 Lamp Elec. TT5

 

 

 

(40 Watt)

 

PB

 

 

 

LOL TT5 Dimming

 

 

 

*Instant Start Standard

 

 

 

 

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

SPECIAL LENSES: Substitute VB for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for VA (standard) =

.125" nominal pattern 12 with 6.8 oz. average weight per square foot. SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF.

AIR CLOSURE STRIP: SUFFIX ACS2 (factory installed).

ELECTRICAL WIRING OPTIONS: Consult factory.

DRYWALL KIT: Order Catalog Number: FK92X2.

Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 3 lamp 40W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To prevent glare the VCP shall be not less than 36 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 4656 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.2%.

AIR HANDLING: (PRA only) side air passages for air supply or air return. Supply

air is discharged vertically. Optional side closure strips. Air return is also pro- vided through the lamp compartment through fixture body ends.

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling. FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pat- tern 12). VB (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and ULc Listed.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier PRA2GRFVA3FT dimensions Page 2 of, Photometry, Ordering Information, Options & Accessories, Specifications, Type