2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T5 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Photometry

CERTIFIED TEST REPORT NO. LSCA018

COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP228120PG

SILVER BALL. COVER, WHITE REFLECTOR, PERF. LAMP SHIELD, WHITE OVERLAY TWO 28W T5 FLUORESCENT LAMPS. LUMEN RATING = 2610 LMS.

ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B228PUNV-C

 

 

CANDLEPOWER SUMMARY

 

OUTPUT

 

 

 

 

 

 

LUMENS

ANGLE ALONG

22.5

45

67.5

ACROSS

 

0

1311

1311

1311

1311

1311

 

5

1305

1307

1307

1305

1299

126

10

1290

1297

1292

1289

1287

 

15

1263

1265

1272

1276

1274

358

20

1217

1222

1236

1245

1253

 

25

1165

1175

1196

1200

1210

548

30

1100

1119

1143

1156

1163

 

35

1027

1042

1075

1101

1113

671

40

945

963

1004

1051

1055

 

45

847

877

927

975

992

714

50

742

780

845

901

919

 

55

635

679

763

821

833

668

60

523

580

663

713

727

 

65

409

465

562

592

595

522

70

316

370

435

436

423

 

75

206

259

279

272

269

282

80

119

151

141

158

164

 

85

38

44

56

57

57

63

90

0

0

0

0

0

 

 

ZONAL LUMENS AND

PERCENTAGES

 

ZONE

 

LUMENS

% LAMP

%LUMINAIRE

0-30

 

1031

19.77

26.12

0-40

 

1702

32.62

43.11

0-60

 

3083

59.08

78.06

0-90

 

3950

75.68

100.00

40-90

 

2247

43.06

56.89

60-90

 

866

16.60

21.94

90-180

0

 

.00

 

.00

0-180

 

3950

75.68

100.00

 

 

** EFFICIENCY = 75.7%

**

LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .92 S/MH = 1.3 SC = 1.3

ANGLE

ALONG

45

ACROSS

CERTIFIED BY:

45

1718

1887

2019

DATE:

55

1587

1915

2091

DEC 5, 2003

65

1387

1911

2027

PREPARED FOR:

75

1142

1545

1498

LIGHTOLIER-CFI

85

627

918

942

CORNWALL, ONTARIO

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Model No. : QHE2GPFOP228120PG

LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO

CERTIFIED TEST REPORT NO. LSCA018

COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP228120PG

SILVER BALL. COVER, WHITE REFLECTOR, PERF. LAMP SHIELD, WHITE OVERLAY TWO 28W T5 FLUORESCENT LAMPS. LUMEN RATING = 2610 LMS.

ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B228PUNV-C

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

 

ZONAL CAVITY

METHOD

 

 

 

 

 

 

 

 

 

 

 

 

EFFECTIVE FLOOR CAVITY

REFLECTANCE = .20

 

 

 

 

 

CC

 

 

80

 

 

 

70

 

 

50

 

 

30

 

 

10

 

0

WALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.90

.90 .90 .90

.88

.88 .88 .88

.84

.84 .84

.81 .81 .81

.77

.77 .77

.76

1

.83

.79 .76 .74

.81

.78 .75 .72

.74

.72 .70

.72 .70 .68

.69

.67 .66

.64

2

.76

.70 .65 .61

.74

.68 .64 .60

.66

.62 .58

.63 .60 .57

.61

.58 .56

.54

3

.69

.61 .56 .51

.67

.60 .55 .50

.58

.53 .50

.56 .52 .49

.54

.51 .48

.46

4

.63

.55 .48 .43

.62

.54 .48 .43

.52

.46 .42

.50 .45 .42

.48

.44 .41

.40

5

.58

.48 .41 .36

.56

.47 .41 .36

.46

.40 .36

.44 .39 .35

.43

.38 .35

.33

6

.53

.43 .36 .31

.52

.42 .36 .31

.41

.35 .31

.40 .34 .31

.38

.34 .30

.29

7

.49

.38 .32 .27

.48

.38 .32 .27

.37

.31 .27

.36 .30 .27

.35

.30 .26

.25

8

.45

.34 .28 .23

.44

.34 .28 .23

.33

.27 .23

.32 .27 .23

.31

.26 .23

.21

9

.41

.31 .25 .20

.40

.31 .24 .20

.30

.24 .20

.29 .24 .20

.28

.23 .20

.18

10

.38

.28 .22 .18

.37

.28 .22 .18

.27

.21 .18

.26 .21 .17

.26

.21 .17

.16

 

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS =

64.6

 

 

 

 

 

 

 

 

LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE.

 

 

 

 

 

 

BALLAST FACTORS HAVE NOT BEEN APPLIED.

 

 

 

 

Ordering Information Explanation of Catalogue Number Example: QHE2GPFOP328120PG

QHE

2

G

OP

3

28

QUALITY

 

 

CEILING TYPE

 

 

 

 

 

 

LAMP

 

 

 

VOLTAGE

 

 

 

OPTIONS

HIGH

 

 

Standard exposed

 

 

 

 

 

QUANTITY

 

120V

 

 

 

R = Radio

EFFICIENCY

 

 

T-grid ceilings

 

 

 

 

 

2

 

 

 

277V

 

 

 

Interference Filter

Recessed direct

 

 

 

 

 

 

 

 

 

3

 

 

 

347V

 

 

 

O = Emergency Lighting

indirect soft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System (for Canada)

light high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N = Emergency Lighting

efficiency

FIXTURE

LAMP SHIELD

 

LAMP/FIXTURE

 

 

 

 

System (for U.S.)

optical system

WIDTH

PF = Microperforated

 

 

LENGTH

 

 

 

 

 

 

 

 

BALLAST

 

2'

 

 

 

 

 

 

 

(NOMINAL 46'')

 

 

 

 

 

 

 

 

 

 

28 = 28W T5

 

PI = Electronic linear T5, IS

 

 

 

 

 

 

LAMP SHIELD

 

 

 

 

 

 

 

54 = 54W T5 HO

 

PG* = Electronic linear T5HO, Pro S

 

 

 

 

 

 

 

DETAIL

 

 

 

 

 

* 54W N/A in PI

 

 

 

 

 

 

OP = One piece

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(no center slot)

SPECIFICATIONS

MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image.

FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish.

ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL

Job Information Type:

Lightolier a Genlyte Thomas Company

Technical Information: (978) 657-7600 - (978) 658-0595

631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc.

525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)

A0902

Section 5 / Folio L30-33

®

Page 2
Image 2
Lightolier dimensions Specifications, Page 2 of, Model No. QHE2GPFOP228120PG, Job Information Type, Photometry, A0902