Lighting Systems RT6-8
1BHFPG |
Performance and Quick Calculator
CANDLEPOWER CURVE | CANDLEPOWER |
COEFFICIENTS OF UTILIZATION
180˚ | 175˚ | 165˚ | 155˚ | 145˚ | 135˚ |
1200 |
|
|
|
|
|
1000 |
|
|
|
| 125˚ |
|
|
|
|
| |
800 |
|
|
|
|
|
600 |
|
|
|
| 115˚ |
|
|
|
|
| |
400 |
|
|
|
| 105˚ |
200 |
|
|
|
| 95˚ |
0 |
|
|
|
| 90˚ |
200 |
|
|
|
| 85˚ |
400 |
|
|
|
| 75˚ |
600 |
|
|
|
| 65˚ |
|
|
|
|
| |
800 |
|
|
|
|
|
1000 |
|
|
|
| 55˚ |
1200 |
|
|
|
|
|
0˚ | 5˚ | 15˚ | 25˚ | 35˚ | 45˚ |
REPORT NO: LRL
LAMPS:
LUMENS: 2900
EFFICIENCY: 73.6%
ZONE | 0 | 22 | 45 | 67 | 90 |
Deg. |
|
|
|
|
|
180 | 821 | 821 | 821 | 821 | 821 |
175 | 821 | 827 | 848 | 855 | 867 |
165 | 800 | 860 | 954 | 1027 | 1040 |
155 | 747 | 876 | 1076 | 1234 | 1284 |
145 | 654 | 865 | 1178 | 1366 | 1428 |
135 | 523 | 812 | 1157 | 1267 | 1278 |
125 | 417 | 770 | 1014 | 1102 | 1096 |
115 | 272 | 635 | 734 | 757 | 763 |
105 | 128 | 351 | 398 | 401 | 401 |
95 | 24 | 80 | 94 | 95 | 95 |
90 | 0 | 0 | 0 | 0 | 0 |
85 | 0 | 0 | 0 | 0 | 0 |
75 | 0 | 0 | 0 | 0 | 0 |
65 | 0 | 0 | 0 | 0 | 0 |
55 | 0 | 0 | 0 | 0 | 0 |
45 | 0 | 0 | 0 | 0 | 0 |
35 | 0 | 0 | 0 | 0 | 0 |
25 | 0 | 0 | 0 | 0 | 0 |
15 | 0 | 0 | 0 | 0 | 0 |
5 | 0 | 0 | 0 | 0 | 0 |
0 | 0 | 0 | 0 | 0 | 0 |
| ZONAL LUMEN SUMMARY |
| |
ZONE | LUMENS % BARELAMP % LUMINAIRE | ||
0 | 0.0 | 0.0 | |
4270 | 73.6 | 100.0 | |
4270 | 73.6 | 100.0 |
|
|
|
|
| % EFFECTIVE CEILING CAVITY REFLECTANCE |
|
|
| |||||
|
|
|
|
| 80 |
|
| 70 |
|
| 50 |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| % WALL REFLECTANCE |
|
|
|
| |||
|
|
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 |
|
| RATIO | 0 | 70 | 70 | 70 | 60 | 60 | 60 | 41 | 41 | 41 |
| |
| 1 | 61 | 58 | 56 | 52 | 50 | 48 | 36 | 34 | 33 |
| ||
| 2 | 53 | 49 | 46 | 45 | 42 | 39 | 31 | 29 | 28 |
| ||
| CAVITY | 3 | 47 | 42 | 38 | 40 | 36 | 33 | 27 | 25 | 23 |
| |
| 4 | 41 | 36 | 32 | 35 | 31 | 27 | 24 | 21 | 19 |
| ||
| 5 | 36 | 31 | 27 | 31 | 27 | 23 | 21 | 19 | 16 |
| ||
| ROOM | 6 | 32 | 27 | 23 | 28 | 23 | 20 | 19 | 16 | 14 |
| |
| 7 | 29 | 23 | 20 | 25 | 20 | 17 | 17 | 14 | 12 |
| ||
| 8 | 26 | 21 | 17 | 22 | 18 | 15 | 15 | 13 | 10 |
| ||
|
|
| |||||||||||
|
| 9 | 23 | 18 | 15 | 20 | 16 | 13 | 14 | 11 | 09 |
| |
|
| 10 | 21 | 16 | 13 | 18 | 14 | 12 | 13 | 10 | 08 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SPACING RATIOS: PARALLEL = 1.3 / PERPENDICULAR = 1.5 |
|
| ||||||||
|
|
|
|
|
|
|
|
| |||||
|
|
| ROOM SURFACE REFLECTANCES: 80% CEILING, 50% WALLS, 20% FLOOR |
|
| ||||||||
| 120 |
|
|
|
|
|
| 2000 LUMENS PER LAMP |
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||
FOOTCANDLES | 100 |
|
|
|
|
|
| RCR = 1 (Rm. Width = 10xMtg. Ht. above work plane) | |||||
|
|
|
|
|
| RCR = 5 (Rm. Width = 2xMtg. Ht. above work plane) | |||||||
|
|
|
|
|
|
| |||||||
80 |
|
|
|
|
|
| RCR = 10 (Rm. Width = Mtg. Ht. above work plane) | ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
60 |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Fixture Lengths & Mounting Locations
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 48" (121.92cm) |
|
|
|
|
| 96" (243.84cm) |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
Sample Run
|
|
| 96" (243.84cm) |
|
|
|
| 96" (243.84cm) |
| |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |||
|
| POWER FEED |
| SINGLE |
|
|
| SINGLE | ||
|
|
|
|
|
| |||||
|
| END SET | STEM OR CABLE |
|
| STEM OR CABLE | ||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
20' 6" (624.84cm)
INITIAL | 40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 20 |
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | 40 |
| 60 | 80 | 100 | 120 | 140 | 160 |
|
|
|
|
| AREA PER FIXTURE IN SQUARE FEET |
|
| ||||
| 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 |
|
|
|
| CENTER TO CENTER DISTANCE OF FIXTURES IN FEET |
| ||||||
48" (121.92cm) |
|
|
|
|
|
|
|
|
|
| |
SINGLE |
|
|
|
|
|
|
|
|
|
| |
STEM OR CABLE |
|
|
| 3” (7.62cm) END SET |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Dimensions given are both fixture | ||||||
|
|
|
|
|
|
| lengths and mounting distances. |
Mounting & Joiner Block Accessories
3” (7.62cm) 6“ (15.24cm) 9" (22.86cm) 12” (30.54cm) 18” (45.72cm) 24” (60.96cm)
Ordering Instructions
Individual Fixtures:
1.Order number of JOINER FIXTURES.
2.Order one POWER FEED END SET per fixture.
3.Order one SINGLE STEM or CABLE ASSEMBLY per JOINER FIXTURE.
Continuous Rows:
3" |
| 3" |
|
|
|
Power Feed End Set Chrome Stem RT62 ED12 = 12" OAL RT62 ED18 = 18" OAL RT62 ED24 = 24" OAL Add WH for
white stem
Power Feed End Set | Single Stem | Cable Assemblies |
Cable/Cord | Chrome | C36 (cable only) |
RT62 EDCC36 | S12 = 12" OAL | CC36 (cable/straight |
(straight cord) | S18 = 18" OAL | cord feed) |
RT62 EDCCC36 | S24 = 24" OAL | CCC36 (cable/coiled |
(coiled cord) | Add WH for | cord feed) |
Max 10 amps. | white stem |
|
1.Determine run length.
2.Order the appropriate number of JOINER FIXTURES for the complete run.
3.Order one POWER FEED END SET per run.
4.Order one SINGLE STEM or CABLE ASSEMBLY per JOINER FIXTURE.
5.For cable mounted runs that exceed amperage limits, order the appropriate number of CABLE/CORD FEEDS.
Square/Rectangle Patterns:
1. | Order appropriate number of JOINER FIXTURES to complete the pattern size. |
2. | Order number and type of JOINER BLOCKS required. |
| 9" |
| 6" |
9" | 6" |
|
"L" Joiner Block
12" |
6" |
6" |
9" |
"T" Joiner Block
| 12" |
| 6" |
9" | 6" |
|
"X" Joiner Block
RT62-XD
3. | Order one SINGLE STEM or CABLE ASSEMBLY per JOINER FIXTURE. |
4. | For cable mounted patterns that exceed amperage limits, order the appropriate |
| number of CABLE/CORD FEEDS. |
Inline joiner block available: RT62ILD
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.