Lightolier SC 1BHFPG, Performance, Fixture Lengths & Mounting Locations, Sample Run, Type

Models: SC

1 2
Download 2 pages 53.95 Kb
Page 2
Image 2
1BHFPG

Lighting Systems Silhouette® SC

1BHFPG

-VNJOPVT*OEJSFDU-JHIU5QFS'PPU /PNJOBM 4FDUJPO

Performance

CANDLEPOWER CURVE

180˚

175˚

165˚

155˚

145˚

135˚

1250

 

 

 

 

 

1000

 

 

 

 

125˚

750

 

 

 

90˚

115˚

 

 

 

 

500

 

 

 

 

 

 

 

 

 

105˚

250

 

 

 

 

95˚

 

 

 

 

 

0

 

 

 

 

90˚

 

 

 

 

 

85˚

 

 

 

 

 

75˚

 

 

 

 

 

65˚

 

 

 

 

 

55˚

15˚

25˚

35˚

45˚

REPORT NO: LRL 299-1D

 

CAT NO: SC24I281WH

 

LAMPS: 2 F28T5

 

 

LUMENS: 2900

 

 

EFFICIENCY: 82.3%

 

 

 

 

CANDLEPOWER

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

ZONE

0

22

45

67

90

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

DEG.

 

CANDELAS

 

 

 

 

 

80

 

 

 

70

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

828

828

828

828

828

 

 

 

 

WALL REFLECTANCE

 

 

 

175

827

836

848

868

870

 

 

70

50

30

 

70

50

30

 

50

30

10

 

 

 

 

 

 

165

811

880

963

1056

1062

 

0

78

78

78

 

67

67

67

 

46

46

46

 

155

761

909

1076

1273

1329

RATIO

1

71

68

65

 

61

58

56

 

40

38

37

145

668

905

1201

1423

1466

2

65

59

55

 

55

51

47

 

35

33

31

135

540

859

1177

1363

1409

CAVITY

3

59

52

47

 

50

45

40

 

31

28

26

125

422

821

1094

1298

1264

4

54

46

40

 

46

39

34

 

27

24

22

115

268

651

918

1023

1029

 

5

49

40

34

 

42

35

30

 

24

21

18

105

141

479

578

557

557

ROOM

6

45

36

30

 

38

31

26

 

21

18

16

90

10

15

12

11

12

8

38

29

23

 

32

25

20

 

17

14

12

95

33

128

129

121

117

 

7

41

32

26

 

35

28

23

 

19

16

14

85

0

0

0

0

0

 

9

35

26

20

 

30

22

18

 

16

12

10

75

0

0

0

0

0

 

10

33

24

18

 

28

21

16

 

14

11

9

 

65

0

0

0

0

0

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

55

0

0

0

0

0

 

 

 

 

DISTRIBUTION

 

 

 

 

 

 

45

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

35

0

0

0

0

0

 

Zone

Lumens

% Lamp

 

 

% Luminaire

 

 

25

0

0

0

0

0

 

0-90

 

0

 

 

0.0

 

 

 

0.0

 

 

15

0

0

0

0

0

 

90-180

 

4776

 

 

82.3

 

 

 

100.0

 

 

5

0

0

0

0

0

 

0-180

 

4776

 

 

82.3

 

 

 

100.0

 

 

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

Quick Calculator and Ceiling Brightness

 

2,000

 

FOOTCANDLE

 

 

 

20

30

50

70

100

 

 

 

 

 

FEET

1,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

7

10

20

30

40 50

70

100

200

NUMBER OF FIXTURES REQUIRED

1.Find room area on vertical axis.

2.Move across chart to footcandle curve.

3.Move down to horizontal axis and read number of fixtures required.

Suspension Length

12"

18"

24"

Footlamberts Above Fixture

165

112

85.7

Footlamberts Between Fixtures

24.7

26.3

32.2

Ceiling Brightness Ratio

6.7

4.3

2.7

Reflectances of 80% ceiling, 50% walls and 20% floor. Light loss factor is .85, Room size is 50' x 50',

Run Spacing 10’. Ceiling Height 9’ to 12’. Values are taken from the center of the room.

Fixture Lengths & Mounting Locations

4-Foot Joiner

 

 

 

 

 

 

 

5/8” (1.59cm)

 

 

 

 

 

 

 

8-Foot Joiner

 

 

 

 

 

 

 

 

 

48” (121.92cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/4” (3.18cm)

96” (243.84cm)

Sample Run

8-Foot Joiner

4-Foot Joiner

8-Foot Joiner

Cable

Power Feed

Assembly

End Set

96” (243.84cm)

48” (121.92cm)

96” (243.84cm)

 

20’ 1/8” (609.92cm)

Mounting & Joiner Block Accessories

4.6” (11.68cm)

4” (10.16cm)

8”

(20.32cm)

PerformanceCANDLEPOWER CURVELUMENS: 2900 4” COEFFICIENTS OF UTILIZATIONCANDELAS (10.16cm)

8” (20.32cm)

4” (10.16cm)

3.4”

4”

(8.64cm)

(10.16cm)

Cable Assembly

Power Feed End Set

“L”Block with Suspension

“X” Block with Suspension

“T” Block with Suspension

SC36

SE36WH (white)

SL36WH (white)

SX36WH (white)

 

ST36WH (white)

 

SE36AL (aluminum)

SL36AL (aluminum)

SX36AL (aluminum)

 

ST36AL (aluminum)

Inline block available (SI36WH or SI36AL).

 

 

 

 

 

 

Job Information

Type:

 

 

 

 

 

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier SC 1BHFPG, Performance, Fixture Lengths & Mounting Locations, Sample Run, Type, Candlepower Curve, Lumens