Cleanlite Enclosed Industrial Fluorescent SC Series

Page 2 of 2

Damp and Wet Locations, 1, 2 or 3 Lamp T5 or T8

Model No. SC4DC232120SO

LER = FP - 72.8 IW - 53.8 BF - 0.87 Comparative yearly lighting energy cost per

1000 lumens = $3.30

Report Number: G92060

Catalog Number: SC4DC232120SO

Lamps: F32T8

Luminaire: Cleanlite enclosed industrial with clear one-piece acrylic lens. Ballast: Triad B232I120RH-A

Report is based on 2850 Lumens per lamp. Efficiency: 79.0%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.5

Shielding Angles:

 

 

90

 

 

90

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

80

75

71

71

68

65

67

64

62

02

71

64

58

60

56

51

57

53

49

03

64

56

49

52

47

42

49

44

40

04

58

49

42

46

40

35

43

38

34

05

53

43

36

41

34

30

39

33

29

06

49

39

31

37

30

26

35

29

25

07

45

35

28

33

27

22

31

26

22

08

42

32

25

30

24

20

29

23

19

09

39

29

22

28

22

18

26

21

17

10

37

27

20

25

20

16

24

19

16

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

4256.

4473.

5156.

55

3770.

4644.

5139.

65

3020.

4376.

4769.

75

1939.

3978.

4608.

85

903.

3389.

4159.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1032

1032

1032

 

5

1022

1034

1047

 

15

979

1020

1057

 

25

899

992

1068

 

35

785

940

1058

 

45

642

870

1070

 

55

473

818

983

 

65

290

667

806

 

75

124

493

653

 

85

27

311

458

 

90

12

231

367

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

846

15.0

19.0

00-040

1431

25.0

32.0

00-060

2792

49.0

62.0

00-090

4170

73.0

92.0

90-180

350

6.0

8.0

00-180

4520

79.0

100.0

Model No. SC4DC354120PG

LER = FP - 66.0 IW - 154.9 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.64

Report Number: G2005352

Catalog Number: SC4DC354120PG

Lamps: F54T5 HO

Luminaire: Cleanlite enclosed industrial with clear one-piece acrylic lens.

Ballast: QTP2X54T5/UNV PSN

Report is based on 4400 Lumens per lamp. Efficiency: 76.6%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.5

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

80

76

72

70

67

64

66

64

61

02

72

65

59

60

55

51

57

53

49

03

65

56

49

52

46

42

49

44

41

04

59

49

42

46

40

35

43

38

34

05

54

44

36

41

34

30

39

33

29

06

50

39

32

36

30

26

35

29

25

07

46

35

28

33

27

23

31

26

22

08

43

32

25

30

24

20

29

24

20

09

40

29

23

28

22

18

26

21

18

10

38

27

21

25

20

16

24

19

16

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

9560.

10660.

10455.

55

8568.

10308.

10046.

65

6941.

10084.

10303.

75

4495.

10407.

9715.

85

2070.

7912.

6981.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

2538

2538

2538

 

5

2507

2537

2569

242

15

2401

2525

2593

709

25

2213

2410

2569

1109

35

1943

2265

2516

1412

45

1602

2084

2336

1554

55

1194

1770

2050

1532

65

742

1439

1839

1372

75

320

1138

1433

1069

85

69

575

782

574

90

26

391

581

 

95

54

296

520

309

105

44

68

197

115

115

24

72

57

53

125

15

54

63

39

135

10

22

49

20

145

0

0

20

5

155

0

0

0

0

165

0

0

0

0

175

0

0

0

0

180

0

0

0

0

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

2061

15.6

20.4

00-040

3473

26.3

34.3

00-060

6559

49.7

64.8

00-090

9574

72.5

94.7

90-120

477

3.6

4.7

90-130

516

3.9

5.1

90-150

541

4.1

5.3

90-180

541

4.1

5.3

00-180

10115

76.6

100.0

Ordering Information

Explanation of Catalog Number. Example: SC4DC232120SO

SC

 

4

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

Cleanlite:

 

Fixture

 

Location:

Lens:

Industrial

 

Length

 

D = Dry and

C = Clear

Fluorescent

 

4 = 4' Length

 

Damp

 

 

for

 

 

 

 

Locations

 

 

Damp

 

 

 

 

W =Wet

 

 

Locations

 

 

 

 

Locations

 

 

Options/Accessories

Tamperproof Latches: Suffix: TP.

Optional Lenses: Lexan lenses or DR acrylic lens. Consult factory.

 

 

 

32

 

 

 

 

 

Number of

Lamp/Watts

Lamps in

(By others)

Width:

32 = 32W T8

1, 2 or 3 Lamps

28 = 28W T5

 

 

 

54 = 54W T5

 

 

 

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

 

Options:

120, 277 or

 

 

 

Add appropriate

UNV=120-277

 

 

 

suffix to catalog

 

 

 

 

 

 

 

 

 

no, ie: (TP)

 

 

 

Ballast

 

Type:

<10THD

 

 

 

 

 

 

 

 

 

<20THD

1 & 2

Lamp Elec. T8

 

SO *

HI *

1-3 Lamp Elec. T8

 

O3 *

H3 *

1 & 2

Lamp 28W Elec. T5

 

 

 

PI

1 & 2

Lamp 28W or 54W Elec. T5

PG ††

1-3 Lamp 54W Elec. T5

 

 

 

PU ††

LOL T8 Dimming

 

PS*

 

Other dimming options. Consult factory.

* Instant Start Standard

† Instant Start (120, 277).

††Program Rapid Start (UNV only).

NOTE:

For T8 UNV, you must use HI, H3 Ballast Code.

Specifications

Materials: Chassis shall be 20 gauge steel.

Wireway Cover: Full length retained by fasteners for quick removal and convenient servicing.

Lens: One-piece flanged lens enclosure molded from .125" thick smooth water- clear virgin acrylic. Lens enclosure shall be heavy-duty enclosed and gasketed with closed-cell foam gasketing (permanently attached to fixture housing). Latches: Lock-tight cam action.

Finish: Chassis shall be phosphate primed and finished in baked white acrylic enamel for not less than 86% reflectivity.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

Type:

 

 

Lightolier

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 a Genlyte company

Section 7/Folio Q30-21 Rev. C

Page 2
Image 2
Lightolier SC Series dimensions Ordering Information, Options/Accessories, Specifications

SC Series specifications

Lightolier SC Series: Illuminate Your Space with Innovation

The Lightolier SC Series is a remarkable range of lighting fixtures designed to elevate the aesthetic and efficiency of any space. Renowned for its sleek designs and advanced technologies, the SC Series offers a perfect solution for residential, commercial, and architectural lighting needs.

One of the standout features of the SC Series is its versatility. The series includes a diverse selection of products, from recessed lighting to surface mount fixtures, providing options for various installation requirements. Each fixture is engineered to seamlessly blend into different environments, enhancing both contemporary and traditional aesthetics.

Another impressive characteristic of the SC Series is its emphasis on energy efficiency. Many models in the series are equipped with LED technology, which not only significantly reduces energy consumption but also contributes to lower operating costs. The long lifespan of LED lights ensures minimal maintenance and replacement, making the SC Series a practical choice for busy environments.

In addition to energy efficiency, the SC Series incorporates advanced optical technologies designed to optimize light distribution. The fixtures feature unique lenses and reflectors that create uniform illumination while minimizing glare. This technology makes them ideal for settings such as offices, retail spaces, and galleries, where the quality of light plays a crucial role in enhancing the experience.

The SC Series also integrates smart controls that can be easily installed and programmed. These systems allow users to adjust lighting levels and create personalized lighting scenes, providing greater control over the ambiance of a space. Whether it’s via smartphone apps or wall-mounted controls, these features contribute to the overall convenience and modernity of the SC Series.

Durability is another essential aspect of the Lightolier SC Series. The fixtures are constructed with high-quality materials designed to withstand varying environmental conditions, making them suitable for both indoor and outdoor applications. Their robust design ensures they maintain their performance and appearance over time.

In conclusion, the Lightolier SC Series combines style, efficiency, and advanced technology into one comprehensive lighting solution. With its diverse range of options, energy-efficient designs, superior light quality, intelligent controls, and durable construction, the SC Series is designed to meet the needs of any lighting project. Whether you are illuminating a home, an office, or a public space, the Lightolier SC Series is a sound choice for innovative and effective lighting.