Lighting Systems Silhouette® SG
1BHFPG | %JSFDU-PVWFSFE-JHIU5QFS'PPU /PNJOBM 4FDUJPO |
Performance
CANDLEPOWER CURVE
180˚ | 175˚ | 165˚ | 155˚ | 145˚ | 135˚ |
|
|
|
|
| 125˚ |
|
|
|
|
| 115˚ |
|
|
|
|
| 105˚ |
|
|
|
|
| 95˚ |
0 |
|
|
|
| 90˚ |
125 |
|
|
|
| 85˚ |
|
|
|
|
| |
250 |
|
|
|
| 75˚ |
|
|
|
|
| |
375 |
|
|
|
| 65˚ |
|
|
|
|
| |
|
| 0˚ | 90˚ |
|
|
500 |
|
|
|
| |
|
|
|
| 55˚ | |
|
|
|
|
| |
625 |
|
|
|
|
|
0˚ | 5˚ | 15˚ | 25˚ | 35˚ | 45˚ |
REPORT NO: LRL |
| ||||
CAT NO: SG14I281WH |
| ||||
LAMPS: 1 F28T5 |
|
| |||
LUMENS: 2900 |
|
| |||
EFFICIENCY: 55.0% |
|
|
|
| CANDLEPOWER |
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
| ||||||||
ZONE | 0 | 22 | 45 | 67 | 90 |
|
| % EFFECTIVE CEILING CAVITY REFLECTANCE |
|
| ||||||||
DEG. |
| CANDELAS |
|
|
|
| 80 |
|
|
| 70 |
|
| 50 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
180 | 41 | 41 | 41 | 41 | 41 |
|
|
|
| WALL REFLECTANCE |
|
|
|
| ||||
175 | 42 | 42 | 42 | 42 | 42 |
|
| 70 | 50 | 30 |
| 70 | 50 | 30 | 50 | 30 | 10 |
|
165 | 40 | 40 | 42 | 45 | 45 |
| 0 | 63 | 63 | 63 |
| 61 | 61 | 61 | 56 | 56 | 56 |
|
155 | 37 | 38 | 46 | 52 | 54 | RATIO | 1 | 58 | 55 | 53 |
| 56 | 53 | 51 | 49 | 48 | 46 | |
145 | 31 | 36 | 49 | 57 | 61 | 2 | 54 | 50 | 46 |
| 51 | 48 | 45 | 44 | 42 | 40 | ||
135 | 22 | 32 | 47 | 60 | 65 | CAVITY | 3 | 50 | 45 | 41 |
| 48 | 43 | 40 | 40 | 37 | 35 | |
125 | 17 | 29 | 50 | 66 | 66 | 4 | 46 | 40 | 36 |
| 44 | 39 | 35 | 36 | 33 | 31 | ||
115 | 7 | 19 | 44 | 61 | 66 |
| 5 | 43 | 36 | 32 |
| 41 | 35 | 31 | 33 | 30 | 27 | |
105 | 2 | 12 | 45 | 60 | 59 | ROOM | 6 | 40 | 33 | 29 |
| 38 | 32 | 28 | 30 | 27 | 24 | |
90 | 4 | 22 | 55 | 68 | 51 | 8 | 34 | 28 | 23 |
| 33 | 27 | 23 | 25 | 22 | 19 | ||
95 | 3 | 17 | 51 | 64 | 54 |
| 7 | 37 | 30 | 26 |
| 35 | 29 | 25 | 28 | 24 | 22 | |
85 | 10 | 29 | 63 | 76 | 59 |
| 9 | 32 | 25 | 21 |
| 31 | 25 | 21 | 23 | 20 | 18 | |
75 | 34 | 60 | 88 | 113 | 112 |
| 10 | 29 | 22 | 18 |
| 28 | 22 | 18 | 21 | 17 | 15 |
|
65 | 61 | 107 | 111 | 133 | 146 |
|
|
| 20% FLOOR CAVITY REFLECTANCE |
|
| |||||||
55 | 99 | 166 | 206 | 210 | 208 |
|
|
|
|
|
|
|
|
|
|
|
|
|
45 | 183 | 261 | 307 | 327 | 330 |
|
|
|
| DISTRIBUTION |
|
|
|
| ||||
35 | 291 | 364 | 420 | 458 | 472 |
| Zone |
|
|
|
|
| ||||||
|
| Lumens |
| % Lamp |
| % Luminaire | ||||||||||||
25 | 384 | 441 | 515 | 560 | 573 |
|
|
|
| |||||||||
|
| 1329 |
|
| 45.8 |
|
| 83.3 |
|
| ||||||||
15 | 453 | 481 | 537 | 587 | 590 |
|
|
|
|
|
|
|
| |||||
|
| 266 |
|
| 9.2 |
|
| 16.7 |
|
| ||||||||
5 | 501 | 503 | 511 | 519 | 520 |
|
|
|
|
|
|
|
| |||||
|
| 1596 |
|
| 55.0 |
|
| 100.0 |
|
| ||||||||
0 | 505 | 505 | 505 | 505 | 505 |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7
Quick Calculator
| 2,000 |
| FOOTCANDLE |
|
|
|
|
|
|
| 20 | 30 | 50 | 70 | 100 |
| |||||||||||
FEET | 1,000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
700 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SQUARE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
IN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
400 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
AREA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
300 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
ROOM | 200 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 1 | 2 | 3 | 4 | 5 | 7 | 10 | 20 | 30 | 40 50 | 70 |
| 100 | 200 |
NUMBER OF FIXTURES REQUIRED
1.Find room area on vertical axis.
2.Move across chart to footcandle curve.
3.Move down to horizontal axis and read number of fixtures required.
Fixture Lengths & Mounting Locations
|
|
|
|
|
|
| 5/8” (1.59cm) | |
|
|
|
|
|
|
| ||
|
|
|
|
|
| |||
|
|
| 48” (121.92cm) |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
96” (243.84cm)
Sample Run | Cable | |||
Power Feed | Assembly | |||
End Set | 96” (243.84cm) | 48” (121.92cm) | 96” (243.84cm) |
|
20’ 1/8” (609.92cm)
Mounting & Joiner Block Accessories
4.6” (11.68cm)
4” (10.16cm)
8” |
(20.32cm) |
4” (10.16cm)
8” (20.32cm) | |
4” (10.16cm) | |
3.4” | 4” |
(8.64cm) | (10.16cm) |
Cable Assembly | Power Feed End Set | “L”Block with Suspension | “X” Block with Suspension | “T” Block with Suspension | ||
SC36 | SE36WH (white) | SL36WH (white) | SX36WH (white) |
| ST36WH (white) | |
| SE36AL (aluminum) | SL36AL (aluminum) | SX36AL (aluminum) |
| ST36AL (aluminum) | |
Inline block available (SI36WH or SI36AL). |
|
|
|
|
| |
| Job Information | Type: |
| |||
|
|
|
|
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #