Lightolier SG 1BHFPG, Performance, Quick Calculator, Fixture Lengths & Mounting Locations

Models: SG

1 2
Download 2 pages 52.17 Kb
Page 2
Image 2
1BHFPG

Lighting Systems Silhouette® SG

1BHFPG

%JSFDU-PVWFSFE-JHIU5QFS'PPU /PNJOBM 4FDUJPO

Performance

CANDLEPOWER CURVE

180˚

175˚

165˚

155˚

145˚

135˚

 

 

 

 

 

125˚

 

 

 

 

 

115˚

 

 

 

 

 

105˚

 

 

 

 

 

95˚

0

 

 

 

 

90˚

125

 

 

 

 

85˚

 

 

 

 

 

250

 

 

 

 

75˚

 

 

 

 

 

375

 

 

 

 

65˚

 

 

 

 

 

 

 

90˚

 

 

500

 

 

 

 

 

 

 

 

55˚

 

 

 

 

 

625

 

 

 

 

 

15˚

25˚

35˚

45˚

REPORT NO: LRL 299-1M

 

CAT NO: SG14I281WH

 

LAMPS: 1 F28T5

 

 

LUMENS: 2900

 

 

EFFICIENCY: 55.0%

 

 

 

 

CANDLEPOWER

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

ZONE

0

22

45

67

90

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

DEG.

 

CANDELAS

 

 

 

 

80

 

 

 

70

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

41

41

41

41

41

 

 

 

 

WALL REFLECTANCE

 

 

 

 

175

42

42

42

42

42

 

 

70

50

30

 

70

50

30

50

30

10

 

165

40

40

42

45

45

 

0

63

63

63

 

61

61

61

56

56

56

 

155

37

38

46

52

54

RATIO

1

58

55

53

 

56

53

51

49

48

46

145

31

36

49

57

61

2

54

50

46

 

51

48

45

44

42

40

135

22

32

47

60

65

CAVITY

3

50

45

41

 

48

43

40

40

37

35

125

17

29

50

66

66

4

46

40

36

 

44

39

35

36

33

31

115

7

19

44

61

66

 

5

43

36

32

 

41

35

31

33

30

27

105

2

12

45

60

59

ROOM

6

40

33

29

 

38

32

28

30

27

24

90

4

22

55

68

51

8

34

28

23

 

33

27

23

25

22

19

95

3

17

51

64

54

 

7

37

30

26

 

35

29

25

28

24

22

85

10

29

63

76

59

 

9

32

25

21

 

31

25

21

23

20

18

75

34

60

88

113

112

 

10

29

22

18

 

28

22

18

21

17

15

 

65

61

107

111

133

146

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

55

99

166

206

210

208

 

 

 

 

 

 

 

 

 

 

 

 

 

45

183

261

307

327

330

 

 

 

 

DISTRIBUTION

 

 

 

 

35

291

364

420

458

472

 

Zone

 

 

 

 

 

 

 

Lumens

 

% Lamp

 

% Luminaire

25

384

441

515

560

573

 

 

 

 

 

0-90

 

1329

 

 

45.8

 

 

83.3

 

 

15

453

481

537

587

590

 

 

 

 

 

 

 

 

 

90-180

 

266

 

 

9.2

 

 

16.7

 

 

5

501

503

511

519

520

 

 

 

 

 

 

 

 

 

0-180

 

1596

 

 

55.0

 

 

100.0

 

 

0

505

505

505

505

505

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

Quick Calculator

 

2,000

 

FOOTCANDLE

 

 

 

 

 

 

 

20

30

50

70

100

 

FEET

1,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

7

10

20

30

40 50

70

 

100

200

NUMBER OF FIXTURES REQUIRED

1.Find room area on vertical axis.

2.Move across chart to footcandle curve.

3.Move down to horizontal axis and read number of fixtures required.

Fixture Lengths & Mounting Locations

4-Foot Joiner

 

 

 

 

 

 

 

5/8” (1.59cm)

 

 

 

 

 

 

 

8-Foot Joiner

 

 

 

 

 

 

 

 

 

48” (121.92cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/4” (3.18cm)

96” (243.84cm)

Sample Run

8-Foot Joiner

4-Foot Joiner

8-Foot Joiner

Cable

Power Feed

Assembly

End Set

96” (243.84cm)

48” (121.92cm)

96” (243.84cm)

 

20’ 1/8” (609.92cm)

Mounting & Joiner Block Accessories

4.6” (11.68cm)

4” (10.16cm)

8”

(20.32cm)

PerformanceCANDLEPOWER CURVELUMENS: 2900 4” CANDLEPOWERCANDELAS (10.16cm)

8” (20.32cm)

4” (10.16cm)

3.4”

4”

(8.64cm)

(10.16cm)

Cable Assembly

Power Feed End Set

“L”Block with Suspension

“X” Block with Suspension

“T” Block with Suspension

SC36

SE36WH (white)

SL36WH (white)

SX36WH (white)

 

ST36WH (white)

 

SE36AL (aluminum)

SL36AL (aluminum)

SX36AL (aluminum)

 

ST36AL (aluminum)

Inline block available (SI36WH or SI36AL).

 

 

 

 

 

 

Job Information

Type:

 

 

 

 

 

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier SG 1BHFPG, Performance, Quick Calculator, Fixture Lengths & Mounting Locations, Sample Run, Type, Lumens