Lightolier Silhouette SA 1BHFPG, Performance, Fixture Lengths & Mounting Locations, Type

Models: Silhouette SA

1 2
Download 2 pages 53.38 Kb
Page 2
Image 2
1BHFPG

Lighting Systems Silhouette® SA

1BHFPG

-VNJOPVT*OEJSFDU-JHIU5QFS'PPU /PNJOBM 4FDUJPO

Performance

CANDLEPOWER CURVE

180˚

175˚

165˚

155˚

145˚

135˚

750

 

 

 

 

 

600

 

 

 

 

125˚

450

 

90˚

 

115˚

 

 

 

300

 

 

 

 

105˚

 

 

 

 

 

150

 

 

 

 

95˚

 

 

 

 

 

0

 

 

 

 

90˚

 

 

 

 

 

85˚

 

 

 

 

 

75˚

 

 

 

 

 

65˚

 

 

 

 

 

55˚

15˚

25˚

35˚

45˚

REPORT NO: LRL 299-1J

CAT NO: SA14I281WH

LAMPS: 1 F28T5

LUMENS: 2900

EFFICIENCY: 81.7%

 

 

CANDLEPOWER

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

ZONE

0

22

45

67

90

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

DEG.

 

CANDELAS

 

 

 

 

 

 

80

 

 

 

70

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

607

607

607

607

607

 

 

 

 

 

WALL REFLECTANCE

 

 

 

 

175

606

613

571

629

631

 

 

 

70

50

30

 

70

50

30

50

30

10

 

165

592

629

668

710

705

 

0

 

80

80

80

 

69

69

69

50

50

50

 

155

557

626

686

689

682

RATIO

1

 

72

69

65

 

62

60

57

43

41

40

145

492

595

598

537

528

2

 

66

60

55

 

57

52

48

37

35

33

135

399

496

429

448

461

CAVITY

3

 

60

52

47

 

51

45

41

33

30

27

125

313

363

363

437

434

4

 

54

46

40

 

47

40

35

29

25

23

115

206

236

312

339

346

 

5

 

50

41

34

 

43

35

30

25

22

19

105

113

171

202

216

217

ROOM

6

 

45

36

30

 

39

31

26

23

19

16

90

6

9

22

38

43

8

 

38

29

23

 

33

25

20

18

15

12

95

23

47

48

54

57

 

7

 

42

32

26

 

36

28

23

20

17

14

85

5

10

26

43

46

 

9

 

36

26

20

 

31

23

18

17

13

11

75

4

16

34

51

53

 

10

 

33

24

18

 

29

21

16

15

12

9

 

65

7

20

38

52

58

 

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

55

17

32

48

63

63

 

 

 

 

 

 

DISTRIBUTION

 

 

 

 

45

20

33

45

58

61

 

 

 

 

 

 

 

 

 

 

35

30

34

47

57

59

 

Zone

 

Lumens

% Lamp

 

% Luminaire

25

35

33

43

50

52

 

 

0-90

 

236

 

 

8.1

 

 

10.0

 

 

15

39

36

37

40

41

 

 

90-180

2134

 

 

73.6

 

 

90.0

 

 

5

42

41

40

39

38

 

 

0-180

 

2370

 

 

81.7

 

 

100.0

 

 

0

40

40

40

40

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

Quick Calculator and Ceiling Brightness

 

2,000

 

FOOTCANDLE

 

 

 

 

 

 

20

 

30

 

 

50

70

100

 

FEET

1,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

7

10

20

30

40

50

70

100

200

NUMBER OF FIXTURES REQUIRED

1.Find room area on vertical axis.

2.Move across chart to footcandle curve.

3.Move down to horizontal axis and read number of fixtures required.

Suspension Length

12"

18"

24"

Footlamberts Above Fixture

223

158

121

Footlamberts Between Fixtures

23.5

25.2

27.9

Ceiling Brightness Ratio

9.9

6.3

4.3

Reflectances of 80% ceiling, 50% walls and 20% floor. Light loss factor is .85, Room size is 50' x 50',

Run Spacing 10’. Ceiling Height 9’ to 12’. Values are taken from the center of the room.

Fixture Lengths & Mounting Locations

4-Foot Joiner

 

 

 

 

 

 

 

5/8” (1.59cm)

 

 

 

 

 

 

 

8-Foot Joiner

 

 

 

 

 

 

 

 

 

48” (121.92cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/4” (3.18cm)

96” (243.84cm)

Sample Run

8-Foot Joiner

4-Foot Joiner

8-Foot Joiner

Cable

Power Feed

Assembly

End Set

96” (243.84cm)

48” (121.92cm)

96” (243.84cm)

 

20’ 1/8” (609.92cm)

Mounting & Joiner Block Accessories

4.6” (11.68cm)

4” (10.16cm)

8”

(20.32cm)

PerformanceCANDLEPOWER CURVECANDLEPOWER 4” CANDELASDISTRIBUTION (10.16cm)

8” (20.32cm)

4” (10.16cm)

3.4”

4”

(8.64cm)

(10.16cm)

Cable Assembly

Power Feed End Set

“L”Block with Suspension

“X” Block with Suspension

“T” Block with Suspension

SC36

SE36WH (white)

SL36WH (white)

SX36WH (white)

 

ST36WH (white)

 

SE36AL (aluminum)

SL36AL (aluminum)

SX36AL (aluminum)

 

ST36AL (aluminum)

Inline block available (SI36WH or SI36AL).

 

 

 

 

 

 

 

 

Job Information

Type:

 

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier Silhouette SA 1BHFPG, Performance, Fixture Lengths & Mounting Locations, Sample Run, Type, Candlepower