Lightolier SL110B Page 4 of, Bare Lamp Stand-OffUnit 1-28WT5 Linear, Performance, 400, 600, Zone

Models: SL110B

1 5
Download 5 pages 12.93 Kb
Page 4
Image 4
KUBIK 1.0  SL110B

KUBIK 1.0  SL110B

Page 4 of 5

Performance

Candlepower Curve

400

300

200

Report No: C9882

Cat. No: SL110B281a/SL002ALG

1 x 28W T5 at 2610 Lumens

Efficiency: 57.7 %

Candela at Nadir: 312cd

ZONE

 

Candlepower

 

 

 

 

 

 

DEG

ALONG

22.5

45

67.5

ACROSS

 

 

 

0

 

 

312

312

312

312

312

5

 

 

316

313

311

309

304

15

 

284

279

290

303

311

25

 

235

236

264

295

312

35

 

179

191

232

281

309

45

 

120

141

203

265

308

55

 

61

93

172

248

299

65

 

33

52

145

232

287

75

 

22

34

120

218

278

85

 

13

27

102

203

265

90

 

0

21

90

189

253

95

 

0

20

97

198

260

105

 

0

17

97

196

258

115

 

0

11

75

187

252

125

 

0

9

19

82

134

135

 

0

0

0

5

27

145

 

0

0

0

0

0

155

 

0

0

0

0

0

165

 

0

0

0

0

0

175

 

0

0

0

0

0

180

 

0

0

0

0

0

Bare Lamp Stand-Off Unit

1-28W T5 Linear

COEFFICIENTS OF UTILIZATION

 

 

 

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

 

 

 

80

 

 

 

 

70

 

 

50

 

 

 

 

 

 

 

 

Wall Reflectance

 

 

 

 

 

 

 

70

50

30

10

 

70

50

30

10

50

30

10

 

0

.65

.65

.65

.65

 

.62

.62

.62

.62

.56

.56

.56

 

1

.58

.55

.52

.49

 

.55

.52

.49

.47

.47

.44

.42

 

2

.52

.47

.42

.39

 

.49

.44

.40

.37

.40

.37

.34

Ratio

3

.47

.41

.36

.32

 

.45

.39

.34

.31

.35

.31

.28

4

.43

.36

.31

.27

 

.41

.34

.30

.26

.31

.27

.24

5

.39

.32

.26

.22

 

.37

.30

.25

.22

.27

.23

.20

Cavity

 

6

.36

.28

.23

.19

 

.34

.27

.22

.19

.24

.20

.17

7

.33

.25

.20

.17

 

.32

.24

.20

.16

.22

.18

.15

Room

8

.31

.23

.18

.14

 

.29

.22

.17

.14

.20

.16

.13

9

.28

.21

.16

.12

 

.27

.20

.15

.12

.18

.14

.11

 

10

.26

.19

.14

.11

.25 .18

.14

.11

.16

.13

.10

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

 

 

 

 

 

LUMINAIRE INPUT WATTS = 33.2

 

 

 

 

 

 

DISTRIBUTION

 

 

 

 

 

 

 

 

 

 

 

 

ZONE

 

LUMENS

 

% LAMP

 

% LUMINAIRE

 

 

 

 

 

 

0-30

 

235

 

9.05

 

15.68

 

 

 

 

 

 

 

0-40

 

383

 

14.75

 

25.55

 

 

 

 

 

 

 

0-60

 

697

 

26.81

 

46.50

 

 

 

 

 

 

 

0-90

 

1110

 

42.69

 

74.05

 

 

 

 

 

 

 

40-90

 

726

 

27.94

 

48.43

 

 

 

 

 

 

 

60-90

 

412

 

15.88

 

27.48

 

 

 

 

 

 

 

90-180

 

389

 

14.96

 

25.95

 

 

 

 

 

 

 

0-180

 

1499

 

57.65

 

100.00

 

 

 

 

Candlepower Curve

600

500

400

Report No: C9930

Cat. No: SL110B281a/SL002C

1 x 28W T5 at 2610 Lumens

Efficiency: 69.4 %

Candela at Nadir: 537cd

Candlepower

ZONE

DEG

 

 

ALONG

22.5

45

67.5

ACROSS

 

 

0

 

537

537

537

537

537

5

 

536

533

538

544

535

15

496

502

528

552

556

25

436

453

496

541

554

35

362

387

446

502

526

45

274

310

380

447

480

55

194

233

307

375

418

65

116

163

242

301

344

75

50

94

162

194

218

85

8

32

50

49

57

90

0

11

17

11

14

95

0

4

11

13

21

105

0

8

19

19

40

115

0

12

19

28

50

125

0

15

21

33

47

135

0

7

22

35

41

145

0

5

20

30

38

155

0

0

12

25

28

165

0

1

3

8

9

175

3

1

2

1

0

180

2

2

2

2

2

Room Cavity Ratio

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

80

 

 

 

 

70

 

 

50

 

 

 

 

 

Wall Reflectance

 

 

 

 

 

70

50

30

10

 

70

50

30

10

50

30

10

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.82

.82

.82

.82

 

.79

.79

.79

.79

.75

.75

.75

1

.74

.71

.68

.66

 

.72

.69

.67

.64

.65

.63

.61

2

.68

.62

.57

.53

 

.66

.60

.56

.52

.57

.54

.51

3

.62

.55

.49

.45

 

.60

.53

.48

.44

.51

.46

.43

4

.57

.48

.42

.38

 

.55

.47

.42

.37

.45

.40

.36

5

.52

.43

.36

.32

 

.50

.41

.36

.31

.40

.34

.31

6

.47

.38

.32

.27

 

.46

.37

.31

.27

.35

.30

.26

7

.44

.34

.28

.24

 

.42

.33

.28

.23

.32

.27

.23

8

.40

.30

.25

.20

 

.39

.30

.24

.20

.29

.23

.20

9

.37

.28

.22

.18

 

.36

.27

.21

.17

.26

.21

.17

10

.34

.25

.19

.16

.33 .24

.19

.15

.23

.18

.15

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

 

 

 

LUMINAIRE INPUT WATTS = 26.5

 

 

 

 

DISTRIBUTION

 

 

 

 

 

 

 

 

 

 

ZONE

 

LUMENS

 

% LAMP

 

% LUMINAIRE

 

 

 

 

0-30

 

428

 

16.41

 

23.66

 

 

 

 

 

0-40

 

705

 

27.04

 

38.98

 

 

 

 

 

0-60

 

1271

 

48.72

 

70.24

 

 

 

 

 

0-90

 

1703

 

65.25

 

94.07

 

 

 

 

 

40-90

 

997

 

38.21

 

55.09

 

 

 

 

 

60-90

 

431

 

16.53

 

23.83

 

 

 

 

 

90-180

 

107

 

4.11

 

5.93

 

 

 

 

 

0-180

 

1810

 

69.36

 

100.00

 

 

 

 

 

 

Job Information

 

Type:

 

 

 

 

 

Lightolier

www.lightolier.com

Canlyte

 

www.canlyte.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

3015 Louis-Amos, Lachine, Québec

H8T 1C4 • (514) 636-0670 • (514) 636-0460

We reserve the right to change details of design, materials and finish.

 

 

 

© 2008 Philips Group • SL110B.pdf

 

 

 

 