Photometry
Section 3A/Folio H70-11

SLB Surface Box 2' x 2' Fluorescent SLB2SFSVA26U

Page 2 of 2 Flat Steel or Regressed Aluminum Frame, 2-6"U Lamp T8 or T12, 4-2' Linear T8 or T12 Lamp

Photometry

Model No. SLB2SFSVA26U120SO

SLB2SFSVA26U120SO

coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

70

68

45

64

62

60

61

60

59

ratio

2

65

61

57

57

54

52

55

53

51

3

60

54

50

52

48

45

50

47

44

 

cavity

4

55

49

44

46

42

39

45

42

39

5

51

44

38

42

37

34

40

37

34

room

6

47

39

34

38

33

30

37

33

30

7

44

36

30

34

30

27

33

29

26

 

8

40

32

27

31

26

23

30

26

23

 

9

37

29

24

28

23

20

27

23

20

 

10

34

26

21

25

21

18

25

21

18

Ordering Information

Explanation of Catalog Number. Example: SLB2SFSVA26U120SO

SL

B

2

S

VA

 

 

Body Style:

Fixture

Ceiling Type:

 

 

 

 

 

 

 

Lamp

 

 

Surface Box

Width

S = Surface

 

 

 

 

 

Quantity:

 

 

 

 

 

Lens

 

Lens

2 = 2 Lamp

SLB Surface:

 

 

Frame:

Shielding Type:

4 = 4 Lamp

 

FS = Flush full-

VA = Pattern 12

 

Lens Frame

 

 

 

 

size steel

 

lens, .095"

 

Surface

 

 

 

 

 

 

frame

 

nominal pris-

 

Fluorescent

 

 

 

 

 

RA = Regressed

 

matic lens

 

 

 

 

 

 

 

 

 

 

 

 

flush full-

 

(standard).

 

 

 

 

 

 

size

 

see options

 

 

 

 

 

 

aluminum

 

and consult

 

 

 

 

 

 

frame

 

factory.

 

Options & Accessories

Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF.

Electrical/Wiring Options: Consult factory.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.

Suffix: R. One per ballast. Suffix: B.

Stem and Canopy Sets: Suspends fixture 6", 12" 18" or 24" from surface. (Four

per fixture is recommended. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").

Lamp/Fixture Length:

6U = T8, 6"U Lamp

17 = T8, 2' Lamp

20 = T12, 2' Lamp

(Nominal 24")

Voltage:

 

 

 

Options:

120 or 277

 

 

Add appropriate

 

 

 

 

suffix to catalog

 

 

 

 

no, ie: (GLR)

Ballast Type:

 

1- 2 Lamp Mag. T12

LE

 

Standard Electro Magnetic P

 

T12 (20 watt only)

<20THD <10THD

 

 

1-2 Lamp Elec. T8

SO*

HI*

1-4 Lamp Elec. T8

O4*

H4*

LOL Dimming T8

PS*

 

*Instant Start Standard

Other dimming options. Consult factory.

Specifications

Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68. To prevent glare the average brightness at 65° shall not exceed 2022 candelas per square meter. To control veiling reflections, luminaire output in the 30–90° zone shall be not less than 67.5%.

Materials: Chassis parts are die-formed 20 gauge cold rolled steel.

Finish: White baked polyester powder coat.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2002 Lightolier

Page 2
Image 2
Lightolier SLB2SFSVA26U Photometry, Ordering Information, Options & Accessories, Specifications, Job Information, Type