|
|
|
|
|
| Lighting Systems | ||||||||||
1BHFPG |
|
|
|
|
| -JHIU51FS'PPU /PNJOBM 4FDUJPO | ||||||||||
Performance |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
CANDLEPOWER CURVE | CANDLEPOWER |
|
|
| COEFFICIENTS OF UTILIZATION |
| ||||||||||
ZONE | 0 | 22 | 45 | 67 | 90 |
| % EFFECTIVE CEILING CAVITY REFLECTANCE | |||||||||
|
|
|
|
|
|
|
|
|
| |||||||
|
| CANDELAS |
|
|
|
| 80% |
|
| 70% |
|
| 50% |
| ||
DEG. |
|
|
|
|
|
|
| WALL R EFLE CTAN CE |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
180 | 646 | 646 | 646 | 646 | 646 |
| 70 | 50 | 30 | 70 | 50 | 30 | 50 | 30 | 10 | |
175 | 658 | 644 | 641 | 637 | 635 | 0 | 80 | 80 | 80 | 68 | 68 | 68 | 47 | 47 | 47 | |
165 | 626 | 616 | 621 | 626 | 630 | 1 | 73 | 69 | 66 | 62 | 59 | 59 | 40 | 39 | 38 | |
155 | 580 | 577 | 601 | 623 | 635 | 2 | 66 | 60 | 56 | 56 | 52 | 48 | 35 | 33 | 31 | |
3 | 60 | 53 | 47 | 51 | 45 | 41 | 31 | 28 | 26 | |||||||
145 | 512 | 524 | 573 | 625 | 649 | |||||||||||
4 | 55 | 47 | 41 | 47 | 40 | 35 | 27 | 24 | 22 | |||||||
135 | 425 | 454 | 544 | 666 | 737 | 5 | 50 | 41 | 35 | 43 | 35 | 30 | 24 | 21 | 19 | |
125 | 322 | 387 | 574 | 933 | 1129 | 6 | 46 | 37 | 30 | 39 | 32 | 26 | 22 | 18 | 16 | |
115 | 211 | 306 | 889 | 1464 | 1599 | 7 | 42 | 33 | 27 | 36 | 28 | 23 | 20 | 16 | 14 | |
8 | 39 | 30 | 24 | 33 | 25 | 20 | 18 | 14 | 12 | |||||||
105 | 100 | 343 | 1087 | 1481 | 1545 | 9 | 36 | 27 | 21 | 31 | 23 | 18 | 16 | 13 | 11 | |
95 | 21 | 380 | 462 | 482 | 443 | 10 | 34 | 24 | 19 | 29 | 21 | 16 | 15 | 11 | 9 | |
90 | 0 | 0 | 0 | 0 | 0 |
|
| 20% FLOOR CAVITY REFLECTANCE |
|
| DISTRIBUTION |
|
|
| ||
REPORT NO.: ITL53326 |
| Zone Lumens % Lamp | % Luminaire | |||
0 | 0.0 | 0.0 | ||||
LAMPS: | ||||||
4189 | 83.8 | 100.0 | ||||
LUMENS: 5000 | ||||||
EFFICIENCY: 83.8% | 4189 | 83.8 | 100.0 | |||
CAT NO.: S154C04WH |
|
|
|
|
|
Fixture Lengths & Mounting Locations
|
|
|
|
|
|
|
| 4' |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| 4' |
|
|
|
|
|
|
|
|
| Notes: Suspended luminaires can be continuously | |||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| row mounted longer than |
|
|
|
|
|
|
|
|
| 8' |
|
|
|
| capacity of power cords cannot be exceeded. | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| 8' |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
12'
17'
|
|
|
|
|
|
| 21' |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 12' |
|
|
|
|
|
|
|
|
| 8' 6" (259.08cm) |
|
|
|
|
Mounting Accessories
Power Feed Cable End Set | Stem End Set | Intermediate Cable | Intermediate Stem | Intermediate Cable/Cord |
Distance is from the ceiling | Distance is from the ceiling | Distance is from the ceiling | Distance is from the ceiling | Distance is from the ceiling |
line to the top of the lumi- | line to the top of the lumi- | line to the top of the lumi- | line to the top of the lumi- | line to the top of the lumi- |
naire housing. | naire housing. | naire housing. | naire housing. | naire housing. |
36” (91.44cm) Platinum: SECO36SC | 30” (76.20cm) Platinum: SESO3ØSC | 36” (91.44cm) Platinum: SICO36SC | 30” (76.20cm) Platinum: SISO3ØSC | 36” (91.44cm) Platinum: SIPO36SC |
36” (91.44cm) White: SECO36WH | 30” (76.20cm) White: SESO3ØWH | 36” (91.44cm) White: SICO36WH | 30” (76.20cm) White: SISO3ØWH | 36” (91.44cm) White: SIPO36WH |
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #