Section 1A/Folio E60-22

SPECPLUS SPS2GFSVA2FT or 3FT

Page 2 of 2 2'x2' RECESSED FLUORESCENT, LENS FRAME TROFFER, STATIC, 2 OR 3 LAMP, TWIN TUBE T5

PHOTOMETRY

MODEL NO. SPS2GFSVA3FT

Luminaire Efficacy Rating

 

 

LER-65.2 Watts-97.9 BF-0.88

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

84

81

78

76

74

62

73

71

70

ratio

2

78

72

67

68

64

61

65

62

60

3

71

64

58

61

56

52

58

55

51

cavity

4

66

57

51

54

49

45

53

48

45

5

61

52

45

49

44

40

48

43

39

room

6

56

47

40

45

39

35

44

39

35

7

53

43

36

41

36

32

40

35

31

 

 

8

49

39

33

38

32

28

37

32

28

 

9

46

36

30

35

29

26

34

29

26

 

10

43

33

28

32

27

24

32

27

23

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

room size

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

 

45

49

55

62

 

 

42

47

52

59

20

30

 

 

 

38

42

45

51

 

 

35

39

43

49

20

40

 

 

 

35

37

41

45

 

 

30

33

38

42

20

60

 

 

 

32

34

37

40

 

 

27

30

33

37

30

20

 

 

 

46

50

54

60

 

 

45

49

53

58

30

30

 

 

 

39

42

45

50

 

 

36

40

43

48

30

40

 

 

 

35

38

40

43

 

 

31

34

37

41

30

60

 

 

 

32

34

36

38

 

 

27

30

32

35

30

80

 

lengthwise

 

30

32

33

36

 

crosswise

25

28

29

32

40

40

 

 

36

39

41

43

 

32

35

38

41

40

20

 

 

 

48

52

56

60

 

 

47

51

55

59

40

30

 

 

 

40

44

46

50

 

 

38

42

45

49

40

60

 

luminaries

 

32

35

36

38

 

luminaries

28

31

32

36

40

80

 

 

31

33

33

36

 

26

28

29

32

40

100

 

 

 

30

32

32

34

 

 

25

27

27

30

60

30

 

 

 

41

45

47

51

 

 

40

43

46

50

60

40

 

 

 

36

39

41

44

 

 

34

37

39

42

60

60

 

 

 

33

35

36

39

 

 

29

31

33

36

 

 

 

60

80

 

 

 

31

33

33

35

 

 

26

28

29

32

60

100

 

 

 

30

31

31

33

 

 

25

27

27

29

100

40

 

 

 

39

42

43

46

 

 

37

40

42

46

100

60

 

 

 

35

37

37

41

 

 

32

34

35

39

100

80

 

 

 

33

34

34

37

 

 

29

31

31

34

100

100

 

 

 

32

33

32

34

 

 

28

29

29

30

ORDERING INFORMATION

Explanation of Catalog Number. Example: SPS2GFSVA3FT120X3GLR

 

SP

 

S

 

 

2

 

 

 

 

 

 

 

 

 

 

VA

 

 

 

 

 

FT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECPLUS:

 

 

 

 

 

 

FIXTURE

 

 

 

LENS

FRAME:

 

 

LAMP

 

 

Recessed

 

 

 

 

 

 

WIDTH

 

 

 

FS=Flat steel frame

 

 

 

 

QUANTITY

 

 

fluorescent

 

 

 

 

 

 

 

 

 

 

 

 

 

RA=Regressed

 

 

 

 

 

2=2 Lamp

 

 

troffer

 

 

 

 

 

 

 

 

 

 

 

 

 

aluminum frame

 

 

3=3 Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FA=Flat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

aluminum frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATIC

 

 

 

 

 

 

 

CEILING TYPE:

 

 

LENS/SHIELDING TYPE:

 

 

 

LAMP/

 

 

 

 

 

 

 

 

 

 

 

G=Grid (lay-in T bar)

 

 

 

 

VA (virgin acrylic)

 

 

FIXTURE LENGTH:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F=Flanged (overlap) Z spline

 

 

standard (see options and

 

 

 

(Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

and plaster frame

 

 

 

 

 

consult factory)

 

 

 

Twin Tube T5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE:

 

 

OPTIONS:

120 or 277

 

Add appropriate suf-

 

 

 

 

 

fix to catalog no., ie:

 

 

 

 

 

 

(GLR)

 

 

BALLAST TYPE:

<10THD

 

 

 

 

<20THD

1-2 Lamp Elec. TT5

SB*

IB*

(40 Watt)

X3*

I3*

1-3 Lamp Elec. TT5

(40 Watt)

PB

 

 

 

LOL TT5 Dimming

 

 

 

*Instant Start Standard

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

SPECIAL LENSES: Substitute VB for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per square foot.

PLASTER FRAME: Catalog Number PF22 .

CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required

between fixtures. Order Catalog Number: S2FCTRIM (each joint).

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture is standard.

SUFFIX: RF.

FUSING: Internal fast-blow fusing.

SUFFIX: GLR.

Internal slow-blow fusing.

SUFFIX: GMF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

DRYWALL KIT: Order Catalog Number: FK92X2.

Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 3 lamp 40W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .81. To prevent glare the VCP shall be not less than 29 either lengthwise or crosswise (at 100fc level), and the average brightness at 65° shall not exceed 4447 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.5%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling.

FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). VB (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier SPS2GFSVA2FT, SPS2GFSVA3FT Plaster Frame Catalog Number PF22, ELECTRICAL/WIRING Options Consult factory