Sealatron Enclosed Industrial Fluorescent STW Series

Page 2 of 2

Wet/Damp Locations, Rapid Start, Slimline/ High Output, 1 or 2 Lamp T5 or T8

Model No. ST4WA232120SO

LER = FP - 67.9 IW - 53.8 BF - 0.87 Comparative yearly lighting energy cost per

1000 lumens = $3.53

Report Number: G97030

Catalog Number: ST4WA232120SO

Lamps: F32T8

Luminaire: Sealatron, enclosed industrial with 25% high impact DR acrylic lens for wet/damp locations.

Ballast: Triad B232I120RH

Report is based on 2850 Lumens per lamp. Efficiency: 74.8%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.5

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

77

72

68

65

62

59

60

58

56

02

69

62

56

55

51

47

51

48

44

03

62

54

47

48

43

38

45

40

37

04

57

47

40

42

37

32

39

35

31

05

52

42

35

38

32

27

35

30

26

06

48

37

30

34

28

24

32

27

23

07

44

34

27

31

25

21

29

24

20

08

41

31

24

28

22

18

28

21

18

09

38

28

22

26

20

17

24

19

16

10

36

26

20

24

18

15

22

18

14

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

3724.

4172.

4301.

55

3281.

4097.

4315.

65

2750.

4122.

4496.

75

2152.

4428.

4770.

85

1463.

4716.

4702.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

978

978

978

 

5

966

978

987

93

15

925

957

984

271

25

845

912

974

421

35

731

847

946

529

45

588

760

888

579

55

429

651

807

569

65

274

539

728

518

75

141

437

629

436

85

43

300

460

307

90

26

251

409

 

95

24

222

384

232

105

18

147

275

156

115

12

82

150

81

125

8

44

71

38

135

6

24

39

18

145

6

13

22

8

155

5

5

11

3

165

5

3

3

1

175

5

3

2

0

180

3

3

3

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

785

13.8

18.4

00-040

1314

23.1

30.8

00-060

2462

43.2

57.8

00-090

3723

65.3

87.4

90-120

469

8.2

11.0

90-130

507

8.9

11.9

90-150

533

9.4

12.5

90-180

538

9.4

12.6

00-180

4261

74.8

100.0

Model No. ST4WA254120PG

LER = FP - 62.7 IW - 105.1 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.83

Report Number: G2005354

Catalog Number: ST4WA254120SO

Lamps: F54T5 HO

Luminaire: Sealatron, enclosed industrial with 25% high impact DR acrylic lens for wet/damp locations.

Ballast: B254PUNVD

Report is based on 4400 Lumens per lamp. Efficiency: 74.8%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.5

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

77

72

68

64

61

59

60

57

55

02

69

62

56

55

50

47

51

47

44

03

62

53

46

48

42

38

44

40

36

04

57

47

40

42

36

32

39

34

30

05

52

41

34

37

31

27

35

30

26

06

48

37

30

33

28

23

31

26

22

07

44

33

27

30

25

20

28

23

20

08

41

30

24

28

22

18

26

21

17

09

38

28

21

25

20

16

24

19

16

10

36

25

19

23

18

15

22

17

14

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

5489.

6321.

6462.

55

4968.

6253.

6461.

65

4024.

6097.

6743.

75

2832.

7059.

7858.

85

1800.

7996.

7411.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1413

1413

1413

 

5

1391

1414

1434

135

15

1338

1403

1449

396

25

1237

1362

1447

626

35

1093

1288

1433

802

45

909

1188

1359

899

55

681

1019

1220

886

65

420

811

1090

786

75

194

699

1018

688

85

55

496

693

480

90

26

387

568

 

95

38

454

679

423

105

26

259

547

291

115

13

87

202

101

125

0

47

70

37

135

0

28

41

18

145

0

13

27

8

155

0

6

10

1

165

0

0

0

0

175

0

0

0

0

180

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1157

13.2

17.6

00-040

1960

22.3

29.8

00-060

3745

42.6

56.9

00-090

5699

64.8

86.6

90-120

815

9.3

12.4

90-130

852

9.7

13.0

90-150

879

10.0

13.4

90-180

880

10.0

13.4

00-180

6579

74.8

100.0

Ordering Information

Explanation of Catalog Number. Example: ST4WA232120SOR

ST

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

Sealatron

Fixture Length:

Wet/Damp

 

A=50% DR

Enclosed

4=48"

 

Location

 

Acrylic Crepe

Industrial

8=96"

 

W= Wet

 

Lens

Fluorescent

 

 

 

 

Location

 

 

 

 

 

 

 

 

 

 

 

 

D = Damp

Location

‡No product change. New Catalog Number Designation.

Number of

 

Lamp/Fixture

Lamps

 

Length/Watts:

in Width:

32

= 32W

T8 4' Length

1=1 Lamp

28

= 28W

T5 4' Length

1 Lamp in Tandem

54

= 54W

T5 4' Length

96" Unit

59SL = 59W

SL T8, 8' Length

2=2 Lamp

86HO = 86W

T8, 380mA,

2 Lamp in Tandem

8' Length

96" Unit

(1 or 2 Lamps in Tandem

 

 

for 8' Fixtures)

 

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

 

120, 277 or

 

 

 

 

UNV=120-277

 

 

 

 

 

 

 

 

 

 

 

BALLAST:

 

 

 

 

 

 

 

<20THD

1

& 2 Lamp Elec. T8

SO *

 

1-4 Lamp Elec. T8

O4 *

1

& 2 Lamp 28W Elec. T5

1

& 2 Lamp 28W Elec. T5

1

& 2 Lamp 54W Elec. T5

 

1-4 Lamp 54W Elec. T5

 

LOL T8 dimming

PS

OPTIONS:

Add

appropriate

suffix to

<10THD catalog no.,

HI * ie: (R)

H4 *

PI

PG †† PG †† PV ††

Options/Accessories

Water Tight Kits: One installed each end of fixture. For additional kits, order Catalog

Number: STW DC2.

Electrical/Wiring Options: Consult factory.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.

Suffix: R. One per ballast. Suffix: B.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Top Mounting Bracket: Order Catalog Number: STW TOP BRACKET.

Other dimming options. Consult Factory.

*Instant Start Standard

† Instant Start (120, 277)

†† Program Rapid Start (UNV only)

NOTE:

For T8 UNV, you must use HI, H4 Ballast Code.

Specifications

Materials: Inner Chassis parts are die-formed code gauge cold rolled steel, 1-5/8" deep x 4-5/8" channel width.

Lens: Molded, one-piece impact resistant .125" starting thickness smooth virgin acrylic with crepe on inner surface. Lens enclosure shall be fully gasketed to seal fixture from dirt, moisture and other contaminents.

Latches: Lock-tight molded cam-action tension latches, securely clamp to fixture.

Finish: Inner chassis exterior–baked white polyester enamel, 84% minimum reflectance.

Specifications (continued)

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

Type:

 

 

Lightolier

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

Copyright 2006 Lightolier

Section7/Folio Q20-32 REV. D

Page 2
Image 2
Lightolier STW-SERIES dimensions Ordering Information, Options/Accessories, Specifications, Model No. ST4WA232120SO