Indirect/Direct – SD, SE, SF

Lighting Systems

SD 2-Lamp T5 Pierced Indirect/Direct

5

 

 

4

2

2 1/4"

 

3

 

 

 

 

1

 

 

6 1/16"

1. Housing: Extruded

2.

Lamping: Two T5 (28 or

4.

Shielding: Die-formed

Finish: Powder-coated

aluminum. Die-cast

 

54 watt as specified)

 

pierced CRS.

baked white or aluminum

end plate mechanically

 

fluorescent lamps.

5.

Diffuser: Translucent

enamel. Custom colors

attached with no

 

Provided by others.

available, consult factory.

 

 

acrylic diffuser.

exposed fasteners.

3.

Reflector: Die-formed

 

Labels: UL, ULc and IBEW.

 

 

 

 

 

specular aluminum reflector.

Electrical: Specify 120 volt or 277 volt. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Ballast is class “P”, thermally protected, electronic, class “A” sound rating, less than 10% THD, end of lamp life cutoff.

Options & Accessories:

L, T, X, Inline joiner blocks and emergency battery pack available.

Luminaire Lengths:

Individual–46 3/4" and

94 3/4". Joiner–48" and 96".

1250

175˚

165˚

155˚

145˚

135˚

 

Coefficients of

 

180˚

 

 

 

 

 

 

1000

 

 

 

 

 

125˚

Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90˚

 

 

 

 

 

% Wall Reflectance

750

 

 

 

 

115˚

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

105˚

 

 

70

50

30

250

 

 

 

 

 

95˚

 

0

82

82

82

0

 

 

 

 

 

90˚

 

1

75

71

68

 

 

 

 

 

 

85˚

Ratio

500

 

 

 

 

 

3

62

54

49

 

 

 

 

 

75˚

250

 

 

 

 

 

 

 

2

68

62

57

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

65˚

Cavity

4

57

48

42

750

 

 

 

 

 

 

5

52

43

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55˚

Room

6

47

38

32

15˚

25˚

35˚

45˚

 

8

40

31

25

1250

 

 

 

 

 

 

 

7

44

34

28

82.2% efficiency

 

 

 

9

37

28

22

 

 

 

10

35

25

19

2 lamp F28T5

 

 

 

 

 

80%

Effective Ceiling

 

Report No. LRL299-IF

 

 

20% Direct

 

 

 

 

Cavity Reflectance

80% Indirect

 

 

 

20%

Floor Cavity

 

 

 

 

 

 

 

 

 

Reflectance

 

 

2,000

 

FOOTCANDLE

 

 

20

30

 

50

70

 

100

 

 

 

 

 

 

FEET

1,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suspension

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18", rows 10',

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

brightness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ratio 6.8:1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

7

10

20

30

40 50

70

100

200

NUMBER OF FIXTURES REQUIRED

How to Specify

 

 

Finish

Series SD

White

 

Aluminum

28 watt

SD-28-WH

 

SD-28-AL

54 watt

SD-54-WH

 

SD-54-AL

Please refer to the flap at the back of the brochure for complete ordering instructions.

1.Find room area on vertical axis.

2.Move across chart to footcandle curve.

3.Move down to hori- zontal axis and read number of luminaires required.

SE 2-Lamp T5 Louvered Indirect/Direct

1

4

2

3

 

 

 

5

4 1/4"

6 11/16"

Electrical: Specify 120 volt or 277 volt. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Ballast is class “P”, thermally protected, electronic, class “A” sound rating, less than 10% THD, end of lamp life cutoff.

Options & Accessories:

180˚

175˚

165˚

155˚

145˚

135˚

Coefficients of

 

750

 

 

 

 

 

 

600

 

 

 

 

125˚

Utilization

 

 

450

 

 

 

 

115˚

 

 

% Wall Reflectance

 

 

 

 

 

 

 

300

 

 

 

90˚

 

 

70

50

30

 

 

 

 

105˚

 

 

150

 

 

 

 

95˚

 

0

81

81

81

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

90˚

 

1

74

71

68

 

 

 

 

 

85˚

Ratio

150

 

 

 

 

2

68

63

58

 

 

 

 

 

300

 

 

 

 

75˚

3

63

56

50

 

 

 

 

 

 

 

 

 

 

65˚

Cavity

4

57

50

44

450

 

 

 

 

5

53

45

39

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

6

49

40

34

 

 

 

 

55˚

Room

 

 

 

 

 

7

45

36

30

750

 

 

 

 

 

15˚

25˚

35˚

45˚

8

42

33

27

 

 

 

 

 

 

 

9

39

30

24

 

2,000

 

FOOTCANDLE

 

 

 

20

30

 

50

70

 

100

 

 

 

 

 

 

 

FEET

1,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suspension

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18", rows 10',

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

brightness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ratio 3.3:1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

7

10

20

30

40 50

70

100

200

 

 

 

 

 

 

 

 

NUMBER OF FIXTURES REQUIRED

 

 

 

 

 

 

 

 

 

 

 

How to Specify

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Find room area on vertical axis.

2.Move across chart to footcandle curve.

3.Move down to hori- zontal axis and read number of luminaires required.

1. Housing: Extruded

2.

Lamping: Two T5 (28

aluminum. Die-cast

 

or 54 watt as specified)

end plate mechanically

 

fluorescent lamps.

attached with no

 

Provided by others.

exposed fasteners.

3.

Reflector: Die-formed

 

specular aluminum reflector.

4.

Shielding: Die-formed

Finish: Powder-coated

 

CRS.

baked white or aluminum

5.

Louver: Straight blade

enamel. Custom colors

available, consult factory.

 

louver finished to match

 

 

 

housing.

Labels: UL, ULc and IBEW.

L, T, X, Inline joiner blocks and emergency battery pack available.

Luminaire Lengths:

Individual–46 3/4" and

94 3/4". Joiner–48" and 96".

79.3% efficiency

 

10

36

27

22

2 lamp F28T5

80%

Effective Ceiling

 

Report no. LRL299-IE

 

 

Cavity Reflectance

29%

Direct

 

20%

Floor Cavity

 

71%

Indirect

 

 

Reflectance

 

 

 

 

 

 

 

Finish

Series SE

White

 

Aluminum

28 watt

SE-28-WH

 

SE-28-AL

54 watt

SE-54-WH

 

SE-54-AL

Please refer to the flap at the back of the brochure for complete ordering instructions.

SF 2-Lamp T5 Acrylic Indirect/Direct

1

3 2

4 7/16"

 

 

 

 

 

 

7"

 

 

 

1. Housing: Extruded

2. Lamping: Two T5 (28

3. Shielding: Sandblasted

Finish: Powder-coated

 

aluminum. Die-cast

or 54 watt as specified)

1/4" thick acrylic.

 

baked white or aluminum

end plate mechanically

fluorescent lamps.

 

 

 

 

 

enamel. Custom colors

attached with no

Provided by others.

 

 

 

 

 

available, consult factory.

exposed fasteners.

 

 

 

 

 

 

Labels: UL, ULc and IBEW.

 

 

 

 

 

 

 

Electrical: Specify 120 volt or 277 volt. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Ballast is class “P”, thermally protected, electronic, class “A” sound rating, less than 10% THD, thermally protected, end of lamp life cutoff.

Options & Accessories:

L, T, X, Inline joiner blocks and emergency battery pack available.

Luminaire Lengths:

Individual–46 3/4" and

750

175˚

165˚

155˚

145˚

135˚

Coefficients of

 

180˚

 

 

 

 

 

600

 

 

 

 

125˚

Utilization

 

 

450

 

 

 

 

115˚

 

 

% Wall Reflectance

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

70

50

30

 

 

 

 

 

105˚

 

 

150

 

 

 

 

95˚

 

0

96

96

96

 

 

 

 

 

 

0

 

 

 

 

90˚

 

1

87

82

78

300

 

 

 

90˚

85˚

Ratio

3

72

63

56

 

 

 

75˚

150

 

 

 

 

 

 

2

79

72

66

600

 

 

 

65˚

Cavity

4

66

55

48

450

 

 

 

 

 

5

60

49

42

 

 

 

 

 

 

 

 

 

 

 

 

55˚

Room

6

55

44

37

15˚

25˚

35˚

45˚

8

47

36

28

750

 

 

 

 

 

 

7

51

40

32

 

 

 

 

 

 

 

9

44

32

25

89.5% efficiency

 

 

10

40

29

22

2 lamp F28T5

 

80%

Effective Ceiling

 

Report No. LRL299-IH

 

 

Cavity Reflectance

53% Direct

 

 

 

 

 

20%

Floor Cavity

 

47% Indirect

 

 

 

 

Reflectance

 

 

 

 

 

 

 

 

 

 

2,000

 

 

FOOTCANDLE

 

 

20 30

 

 

50

 

70 100

 

 

 

 

 

 

 

FEET

1,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

7

10

 

20

30

40 50

70

100

200

 

 

 

 

 

 

 

 

 

NUMBER OF FIXTURES REQUIRED

 

 

 

 

 

 

 

 

 

How to Specify

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Finish

 

 

 

 

 

 

 

 

 

 

Series SF

 

 

 

White

 

 

 

 

 

 

 

Aluminum

 

 

 

 

 

28 watt

 

 

 

 

SF-28-WH

 

 

 

 

 

 

 

SF-28-AL

 

 

 

 

 

54 watt

 

 

 

 

SF-54-WH

 

 

 

 

 

 

 

SF-54-AL

 

 

Please refer to the flap at the back of the brochure for complete ordering instructions.

1.Find room area on vertical axis.

2.Move across chart to footcandle curve.

3.Move down to hori- zontal axis and read number of luminaires required.

10

94 3/4". Joiner–48" and 96".

11

Page 6
Image 6
Lightolier Indirect/Direct SD, SE, SF, SD 2-Lamp T5 Pierced Indirect/Direct, SE 2-Lamp T5 Louvered Indirect/Direct