Lightolier VPA1G12PR132 Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: VPA1G12PR132

1 2
Download 2 pages 53.33 Kb
Page 2
Image 2
Page 2 of 2
SECTION 2/Folio G05-10 REV. A

 

VP PARABOLIC VPA1G12PR132

Page 2 of 2

1'x4' RECESSED FLUORESCENT, 3" DEEP, 12 CELL (1 ROW) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)

PHOTOMETRY

MODEL NO. VPA1G12PR132120SO

LER = FP - 59.4

 

IW - 30.4

 

BF - 0.88

 

 

 

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.04

 

 

 

 

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF

 

 

20

 

 

 

20

 

 

 

 

 

 

20

 

 

 

 

RC

 

 

80

 

 

 

50

 

 

 

 

 

 

30

 

 

 

 

RW

 

70

50

30

 

50

30

 

10

 

 

50

30

10

 

 

 

1

 

81

79

77

 

74

73

 

72

 

 

72

71

70

 

 

ratio

2

 

77

73

70

 

69

67

 

65

 

 

67

65

63

 

 

3

 

72

67

63

 

64

61

 

58

 

 

62

59

57

 

 

cavity

4

 

67

61

57

 

59

55

 

52

 

 

57

54

52

 

 

5

 

63

56

51

 

54

50

 

47

 

 

53

49

46

 

 

room

6

 

59

52

47

 

50

46

 

42

 

 

49

45

42

 

 

7

 

55

47

42

 

45

41

 

38

 

 

45

41

38

 

 

 

8

 

51

43

37

 

41

37

 

34

 

 

40

36

33

 

 

 

9

 

47

38

33

 

37

33

 

30

 

 

36

32

29

 

 

 

10

 

43

35

30

 

34

29

 

26

 

 

33

29

26

 

 

visual comfort probability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

 

W

 

 

L

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

 

 

20

 

 

20

 

 

93

93

92

82

 

 

 

97

96

95

 

90

 

 

20

 

 

30

 

 

93

93

92

82

 

 

 

97

96

96

 

91

 

 

20

 

 

40

 

 

93

93

92

82

 

 

 

97

96

96

 

92

 

 

20

 

 

60

 

 

93

93

92

83

 

 

 

97

96

96

 

92

 

 

30

 

 

20

 

 

93

93

93

85

 

 

 

97

96

96

 

91

 

 

30

 

 

30

 

 

93

93

93

85

 

 

 

97

96

96

 

92

 

 

30

 

 

40

 

 

93

94

92

85

 

 

 

97

96

96

 

92

 

 

30

 

 

60

 

 

93

94

93

86

 

 

 

98

96

96

 

92

 

 

30

 

 

80

 

lengthwise

93

94

93

86

 

crosswise

 

98

96

96

 

92

 

 

40

 

 

40

 

93

94

93

87

 

 

98

96

96

 

92

 

 

40

 

 

20

 

 

93

93

93

86

 

 

 

97

96

96

 

91

 

 

40

 

 

30

 

luminaries

93

94

92

87

 

luminaries

 

97

96

96

 

92

 

 

40

 

 

60

 

93

94

93

87

 

 

98

96

96

 

92

 

 

40

 

 

80

 

 

94

94

93

87

 

 

 

98

96

96

 

92

 

 

40

 

 

100

 

 

94

94

93

87

 

 

 

98

96

96

 

82

 

 

60

 

 

30

 

 

93

94

93

87

 

 

 

97

96

96

 

92

 

 

60

 

 

40

 

 

93

94

93

87

 

 

 

98

96

96

 

92

 

 

60

 

 

60

 

 

94

94

93

87

 

 

 

98

96

96

 

92

 

 

 

 

 

 

 

 

 

 

 

60

 

 

80

 

 

94

94

93

87

 

 

 

98

96

96

 

92

 

 

60

 

 

100

 

 

94

94

93

87

 

 

 

98

96

96

 

92

 

 

100

 

 

40

 

 

94

94

93

87

 

 

 

98

96

96

 

92

 

 

100

 

 

60

 

 

94

94

93

87

 

 

 

98

96

96

 

92

 

 

100

 

 

80

 

 

94

94

93

87

 

 

 

98

96

96

 

92

 

 

100

 

 

100

 

 

94

94

93

87

 

 

 

98

96

97

 

92

ORDERING INFORMATION

Explanation of Catalog Number. Example: VPA1G12PR132120SOGLR

VP

1

12

P

R

1

 

 

 

 

 

 

 

BLANK = Standard

 

BODY STYLE:

 

N = NYC Code

 

A=Air Handling

 

 

 

 

 

S=Static

 

 

 

VP:

 

 

 

 

 

FIXTURE

 

 

3" Deep

 

WIDTH

 

 

Pre-

 

 

 

 

 

anodized

 

 

 

 

 

Aluminum

 

 

 

 

 

Louver

 

 

 

 

 

for intense

 

 

 

 

 

VDT use

 

 

 

 

 

 

 

 

 

 

CEILING TYPE: G= Grid (lay-in T bar) F=Flanged (overlap)

Z spline and plaster frame.

T=Slot grid or two-directional concealed T (see options)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOUVER

 

 

 

 

LAMP

 

 

 

 

 

 

FINISH:

 

 

 

 

QUANTITY

 

 

 

 

 

 

P=Low

 

 

 

 

 

 

 

 

 

 

 

 

Iridescence

 

 

 

 

 

 

 

 

 

NUMBER OF

Specular

 

REFLECTOR:

 

 

 

LAMP/

CELLS:

 

 

R=Specular

 

 

 

FIXTURE

 

 

 

 

1 row of

 

 

95%

 

 

 

 

LENGTH:

12 cells

 

 

 

Reflective

 

 

 

32=T8

 

 

 

 

 

 

 

 

 

 

 

 

34=T12

(Nominal 48")

VOLTAGE:

 

 

 

 

OPTIONS:

120 or 277

 

 

 

Add appropriate

 

 

 

 

 

suffix to catalog

 

 

 

 

 

no, ie: (GLR)

 

 

 

 

 

 

BALLAST TYPE:

 

1

Lamp Mag.

T12

LE

<10THD

 

 

 

 

<20THD

1

Lamp Elec. T8

SO*

HI*

LOL Dimming

PS

*Instant Start Standard

Other dimming options, consult factory.

OPTIONS & ACCESSORIES

ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify sepa- rately. Order Catalog Number: ACP CSP.

ELECTRICAL WIRING OPTIONS: Consult factory.

FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are

required between fixtures. Order Catalog Number: 1FCTRIM (each joint).

SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 S2 SPLAY TRIM.

AIR CLOSURE STRIPS: SUFFIX ACS4 (factory installed).

DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 1 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .79 with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To meet IES RP-1 preferred for VDT areas the VCP (visual comfort probability) shall not be less than 94 either crosswise or lengthwise, and the maximum average

brightness at 55°, 65°, 75° and 85° shall not exceed 664,109, 0, and 0 candelas per square meter respectively in the 0°, 45° and 90° horizontal planes. Candelas at nadir (0°) not to exceed 967.

AIR HANDLING: (VPA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.

MATERIALS: Chassis parts are die-formed embossed cold rolled steel. Housing is embossed for rigidity with all edges turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak® or equal).

FINISH: Louver—specular low iridescence pre-anodized reflector sheet.

REFLECTOR: Low-iridescence,semi-specular with low iridescence specular center section. Chassis exterior—black baked polyester enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier VPA1G12PR132 dimensions Page 2 of, Photometry, Ordering Information, Options & Accessories, Specifications, Type