Lightolier VRA1G8LS132 Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: VRA1G8LS132

1 2
Download 2 pages 35.69 Kb
Page 2
Image 2
Page 2 of 2
SECTION 2/Folio G05-36 REV. A

 

VR PARABOLIC VRA1G8LS132

Page 2 of 2

1'x4' RECESSED FLUORESCENT, 3" DEEP, 8 CELL (1 ROW) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE

PHOTOMETRY

MODEL NO. VRA1G8LS132120SO

LER = FP - 55.0

 

IW - 30.7

 

BF - 0.88

 

 

 

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.36

 

 

 

 

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF

 

 

20

 

 

 

20

 

 

 

 

 

 

20

 

 

 

 

RC

 

 

80

 

 

 

50

 

 

 

 

 

 

30

 

 

 

 

RW

 

70

50

30

 

50

30

 

10

 

 

50

30

10

 

 

 

1

 

76

73

71

 

69

67

 

66

 

 

67

65

64

 

 

ratio

2

 

71

66

63

 

63

60

 

58

 

 

61

59

57

 

 

3

 

66

60

55

 

57

53

 

51

 

 

55

52

50

 

 

cavity

4

 

61

54

49

 

51

47

 

44

 

 

50

46

44

 

 

5

 

56

48

43

 

46

42

 

38

 

 

45

41

38

 

 

room

6

 

51

43

38

 

41

37

 

33

 

 

40

36

33

 

 

7

 

47

39

33

 

37

32

 

29

 

 

36

32

29

 

 

 

 

 

 

 

 

 

 

 

8

 

43

34

29

 

33

28

 

25

 

 

32

28

25

 

 

 

9

 

39

30

25

 

29

24

 

21

 

 

29

24

21

 

 

 

10

 

36

27

22

 

26

22

 

18

 

 

26

21

18

 

 

visual comfort probability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

 

W

 

 

L

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

 

20

 

 

20

 

 

88

85

80

85

 

 

 

87

82

80

 

79

 

20

 

 

30

 

 

89

87

84

81

 

 

 

89

85

80

 

77

 

20

 

 

40

 

 

89

87

86

84

 

 

 

89

85

83

 

78

 

 

20

 

 

60

 

 

89

88

87

86

 

 

 

89

85

83

 

81

 

30

 

 

20

 

 

90

88

82

84

 

 

 

88

86

81

 

79

 

30

 

 

30

 

 

91

89

85

80

 

 

 

90

88

81

 

77

 

30

 

 

40

 

 

91

89

87

83

 

 

 

90

88

84

 

78

 

30

 

 

60

 

 

91

89

87

85

 

 

 

90

88

84

 

80

 

 

30

 

 

80

 

lengthwise

91

89

87

84

 

crosswise

 

89

88

84

 

81

 

40

 

 

40

 

91

89

88

84

 

 

90

88

85

 

79

 

40

 

 

20

 

 

91

88

84

85

 

 

 

88

86

83

 

81

 

40

 

 

30

 

luminaries

91

89

87

81

 

luminaries

 

90

88

83

 

78

 

40

 

 

60

 

91

89

88

84

 

 

89

88

86

 

81

 

40

 

 

80

 

 

91

89

88

84

 

 

 

90

88

86

 

81

 

 

40

 

 

100

 

 

91

89

88

84

 

 

 

90

88

86

 

81

 

60

 

 

30

 

 

91

89

88

83

 

 

 

90

88

83

 

80

 

60

 

 

40

 

 

91

89

88

85

 

 

 

89

88

85

 

81

 

60

 

 

60

 

 

91

89

89

86

 

 

 

90

88

86

 

83

 

 

 

 

 

 

 

 

 

60

 

 

80

 

 

91

89

89

86

 

 

 

90

88

86

 

83

 

 

60

 

 

100

 

 

91

89

89

86

 

 

 

90

88

86

 

83

 

100

 

 

40

 

 

91

89

89

85

 

 

 

90

88

86

 

81

 

100

 

 

60

 

 

91

89

89

86

 

 

 

90

88

86

 

83

 

100

 

 

80

 

 

91

89

89

86

 

 

 

90

88

86

 

83

 

 

100

 

 

100

 

 

91

89

89

86

 

 

 

90

88

86

 

83

ORDERING INFORMATION

Explanation of Catalog Number. Example: VRA1G8LS132120SOGLR

VR

1

8

S

1

 

 

 

 

BODY STYLE:

 

BLANK = Standard

 

 

N = NYC Code

 

A=Air Handling

 

 

 

 

 

 

S=Static

 

 

 

VR:

 

FIXTURE

 

 

3" Deep

 

WIDTH

 

 

Pre-

 

 

 

 

 

anodized

 

 

 

 

 

Aluminum

 

 

 

 

 

Louver

 

 

 

 

 

for normal

 

 

 

 

 

VDT use

 

 

 

 

 

 

 

 

 

 

CEILING TYPE: G= Grid (lay-in T bar) F=Flanged (overlap)

Z spline and plaster frame

T=Slot grid or two-directional concealed T (see options)

NUMBER OF

CELLS:

1 row of

8 cells

LOUVER

FINISH: L=Low

Iridescence

Semi-specular

(standard)

P=Low

iridescence

specular

 

 

 

 

 

 

 

 

 

 

 

LAMP

 

 

 

 

 

 

QUANTITY

 

 

 

 

 

 

 

 

 

 

 

SINGLE

 

 

 

LAMP/

WHITE

 

 

 

FIXTURE

 

 

REFLECTOR

 

 

 

LENGTH:

 

 

 

 

 

 

32=T8

34=T12 (Nominal 48")

VOLTAGE:

 

 

 

 

OPTIONS:

120 or 277

 

 

 

Add appropriate

 

 

 

 

 

suffix to catalog

 

 

 

 

 

no, ie: (GLR)

 

 

BALLAST TYPE:

 

1

Lamp Mag.

T12

LE

<10THD

 

 

 

 

<20THD

1

Lamp Elec. T8

SO*

HI*

LOL Dimming

PS

*Instant Start Standard

Other dimming options, consult factory.

OPTIONS & ACCESSORIES

ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify sepa- rately. Order Catalog Number: ACP CSP.

ELECTRICAL WIRING OPTIONS: Consult factory.

FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are

required between fixtures. Order Catalog Number: 1FCTRIM (each joint).

SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 S2 SPLAY TRIM.

AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed).

DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 1 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .73 with a spacing to mounting ratio of 1.9 perpendicular to the lamps. To meet IES RP1 recommended (basic) requirements for VDT areas the VCP (visual comfort probability) shall not be less than 90 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 837, 82 and

SPECIFICATIONS (continued)

0 candelas per square meter respectively in the 0°, 45° and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 649.

AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.

MATERIALS: Chassis parts are die-formed embossed cold rolled steel. Housing is embossed for rigidity with all edges turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak@ or equal).

FINISH: Louver—semi-specular low iridescence pre-anodized reflector sheet. Cavity—white baked polyester minimum reflectance 86%. Phosphate under- coating. Chassis exterior—black baked polyester enamel.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier VRA1G8LS132 Page 2 of, Photometry, Ordering Information, Options & Accessories, Specifications, Job Information