SECTION 2/Folio G05-40 REV. A

 

VR PARABOLIC VRA2G9LS26U

Page 2 of 2

2'x2' RECESSED FLUORESCENT, 4" DEEP, 9 CELL (3x3) PARABOLIC LOUVER

 

AIR SUPPLY/RETURN/HEAT EXTRACTION, IES RP1 FOR NORMAL VDT USE

PHOTOMETRY

 

LER = FP - 47.8

IW - 59.2

BF - 93.6

 

 

 

 

 

 

 

 

 

MODEL NO. VRA2G9LS26USO Comparative yearly lighting energy cost per 1000 lumens = $5.02

 

 

 

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

 

RF

 

20

 

 

 

 

20

 

 

 

 

 

 

20

 

 

 

RC

 

80

 

 

 

 

50

 

 

 

 

 

 

30

 

 

 

RW

70

50

30

 

 

50

30

 

 

10

 

50

 

30

10

 

 

ratio

1

64

62

60

 

 

58

57

 

 

56

 

56

 

55

54

 

 

3

55

50

47

 

 

48

45

 

 

43

 

47

 

44

42

 

 

 

2

59

56

53

 

 

53

51

 

 

49

 

51

 

49

48

 

 

cavity

4

51

46

42

 

 

44

40

 

 

38

 

42

 

40

37

 

 

5

48

41

37

 

 

40

36

 

 

33

 

39

 

36

33

 

 

room

6

44

38

33

 

 

36

33

 

 

30

 

35

 

32

30

 

 

8

38

32

27

 

 

30

27

 

 

24

 

30

 

26

24

 

 

 

7

42

34

30

 

 

33

29

 

 

27

 

32

 

29

27

 

 

 

9

36

29

25

 

 

28

24

 

 

22

 

28

 

24

22

 

 

 

10

34

27

23

 

 

26

22

 

 

20

 

26

 

22

20

 

 

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

room size

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

W

 

L

8.5

10.0

13.0

16.0

 

 

 

 

8.5

10.0

13.0

16.0

 

 

 

20

 

20

 

 

 

91

85

77

77

 

 

 

 

92

90

85

76

 

 

20

 

30

 

 

 

92

87

81

77

 

 

 

 

92

90

88

81

 

 

20

 

40

 

 

 

92

89

84

80

 

 

 

 

92

90

88

84

 

 

20

 

60

 

 

 

92

89

86

82

 

 

 

 

92

91

88

84

 

 

 

30

 

20

 

 

 

91

85

81

78

 

 

 

 

92

91

87

77

 

 

30

 

30

 

 

 

92

88

84

78

 

 

 

 

92

91

89

81

 

 

30

 

40

 

 

 

92

89

87

81

 

 

 

 

92

91

89

83

 

 

30

 

60

 

lengthwise

 

92

89

88

83

 

 

 

crosswise

92

91

89

84

 

 

40

 

40

 

 

92

89

87

83

 

 

 

92

91

89

85

 

 

30

 

80

 

 

 

93

90

88

83

 

 

 

 

92

90

89

84

 

 

 

40

 

20

 

 

 

91

85

81

81

 

 

 

 

92

91

87

79

 

 

40

 

30

 

 

 

92

88

84

81

 

 

 

 

92

91

89

83

 

 

40

 

60

 

luminaries

 

93

90

88

85

 

 

 

luminaries

93

90

89

84

 

 

40

 

80

 

 

93

90

88

85

 

 

 

93

90

89

84

 

 

40

 

100

 

 

 

93

90

88

85

 

 

 

 

93

90

89

84

 

 

 

60

 

30

 

 

 

92

83

84

81

 

 

 

 

92

91

89

83

 

 

60

 

40

 

 

 

93

90

87

83

 

 

 

 

92

90

89

84

 

 

60

 

60

 

 

 

93

90

88

85

 

 

 

 

93

90

89

84

 

 

 

 

 

 

 

 

 

 

 

 

60

 

80

 

 

 

93

90

88

85

 

 

 

 

93

90

89

83

 

 

60

 

100

 

 

 

93

90

88

85

 

 

 

 

93

90

89

83

 

 

 

100

 

40

 

 

 

93

90

87

83

 

 

 

 

93

90

89

84

 

 

100

 

60

 

 

 

93

90

88

85

 

 

 

 

93

90

89

83

 

 

100

 

80

 

 

 

93

90

88

85

 

 

 

 

93

90

89

84

 

 

 

100

 

100

 

 

 

93

90

88

85

 

 

 

 

93

90

89

84

 

ORDERING INFORMATION

Explanation of Catalog Number. Example: VRA2G9LS26U120SOGLR

VR

BODY STYLE:

A=Air Handling

S=Static

VR:

4" Deep

Pre-anodized

Aluminum

Louver

For Normal

VDT Use

2

 

 

 

 

9

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CEILING TYPE:

 

 

 

LOUVER

 

 

 

 

G= Grid

 

 

 

FINISH*:

 

 

 

 

 

(lay-in T bar)

 

 

L=Low

 

 

FIXTURE

F=Flanged

NUMBER OF

 

Iridescence

 

 

 

SINGLE “V”

(overlap)

 

Semi-specular

WIDTH

 

Z spline and

CELLS:

 

(standard)

REFLECTOR

 

 

 

plaster

(3 rows of

P=Low

 

 

 

 

frame

3 cells)

 

Iridescence

 

 

 

 

T=Slot grid or

 

 

 

Specular

 

 

two-directional concealed

T (see options)

2 6U

LAMP

QUANTITY

LAMP TYPE/

FIXTURE

LENGTH:

6"U LAMP

T8 OR T12

(Nominal 24")

 

 

 

 

 

 

 

 

 

VOLTAGE:

 

 

 

 

 

 

 

 

OPTIONS:

120 or 277

 

Add appropriate

 

 

 

 

suffix to catalog

 

BALLAST TYPE: no, ie: (GLR)

1-2

Lamp Mag. T12

 

LE

<10THD

 

 

 

<20THD

1-2

Lamp Elec. T8

 

SO*

 

HI*

LOL T8 Dimming

 

PS

 

*Instant Start Standard

Other dimming options consult factory.

OPTIONS & ACCESSORIES

PLASTER FRAME: Catalog Number: PF22.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are

required between fixtures, Order Catalog Number: S2FCTRIM (each joint).

SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

ELECTRICAL WIRING OPTIONS: Consult factory.

AIR CLOSURE STRIPS: SUFFIX ACS2 (factory installed).

DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10.)

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .62 with a spacing to mounting ratio of 1.3 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba- bility) shall not be less than 93 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 357, 130, and 38 cande- las per square meter respectively in the 0°, 45°, and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 1521.

SPECIFICATIONS (continued)

AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak@ or equal).

FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec- tor sheet is standard.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier VRA2G9LS26USO dimensions Options & Accessories, Specifications