Photometry
Section 3A/Folio H90-12 Rev. B

DOMINAIRE II WA SERIES 232

Page 2 of 2 SURFACE WRAPAROUND FLUORESCENT, 9" WIDE x 2 5/8" DEEP x 48" OR 96" LENGTHS 2 LAMP, T8 OR T12

Photometry

Model No. WA4A232120SO

LER = FS - 56.5 Watts - 63.0 BF - 0.88

Comparative yearly lighting energy cost per 1000 lumens = $4.25

WA4A232120SO

REL-2P32-SC

LAMPS: TWO F32 T8, EACH RATED 2850 LUMENS

coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

77

74

71

68

66

64

64

63

61

ratio

2

71

66

61

60

57

54

57

55

53

3

65

59

53

54

50

47

52

48

46

cavity

4

60

52

47

49

44

41

47

43

40

5

55

47

41

44

39

35

42

38

34

room

6

51

42

36

39

35

31

38

34

30

7

47

38

32

36

31

27

34

30

27

 

8

43

34

28

32

27

24

31

26

23

 

9

40

31

25

29

24

21

28

23

20

 

10

37

28

22

26

21

18

25

21

18

visual comfort probability (VCP) average 100 fc; reflectances 80/50/20

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

61

65

72

77

 

 

60

65

71

78

20

30

 

 

54

58

63

69

 

 

53

57

63

69

20

40

 

 

51

53

58

62

 

 

50

53

58

62

20

60

 

 

47

50

53

57

 

 

46

50

53

57

30

20

 

 

62

66

71

76

 

 

61

65

71

76

30

30

 

 

55

58

62

66

 

 

54

57

61

66

30

40

 

 

51

53

56

60

 

 

50

53

56

60

30

60

 

 

48

50

51

54

 

 

46

49

51

55

30

80

 

lengthwise

46

48

48

51

 

crosswise

44

47

48

52

40

40

 

52

54

56

59

 

51

53

56

59

40

20

 

 

63

67

71

76

 

 

63

67

72

76

40

30

 

luminaries

56

59

62

66

 

luminaries

56

59

62

66

40

60

 

49

50

51

54

 

47

49

51

54

40

80

 

 

47

48

48

51

 

 

45

47

48

51

40

100

 

 

47

47

46

49

 

 

44

46

46

49

60

30

 

 

58

60

63

67

 

 

57

60

63

67

60

40

 

 

53

55

57

60

 

 

53

55

56

59

60

60

 

 

50

51

51

54

 

 

48

50

51

54

 

 

60

80

 

 

48

48

48

50

 

 

46

47

48

50

60

100

 

 

47

47

46

48

 

 

44

46

46

48

100

40

 

 

57

58

59

62

 

 

56

58

59

62

100

60

 

 

53

53

53

56

 

 

51

53

53

55

100

80

 

 

50

51

50

52

 

 

48

50

49

51

100

100

 

 

49

49

48

49

 

 

47

48

47

49

Ordering Information Explanation of Catalog Number. Example: WA4A232120SOGLR

WA

 

 

 

DOMINAIRE II:

FIXTURE

Surface Wrap

LENGTH:

Fluorescent

4=4' Length

With White Body

8=8' Length

A

FIXTURE

WIDTH:

A=9" Wide

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONS:

LAMP

 

LAMP

VOLTAGE:

 

 

 

 

 

Add appropriate

QUANTITY

32 =T8, 4' Length

120 or 277

 

 

 

 

 

suffix to catalog

For 4' Fixtures,

34 =T12, 4' Length

 

 

 

 

 

 

 

no., ie: (GLR)

2 Lamps

 

 

 

 

 

 

BALLAST TYPE:

 

For 8' Fixtures,

 

 

 

 

 

 

 

 

 

 

 

1 & 2 Lamp Mag. T12

LE

 

2 Lamps in Tandem

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<20THD

<10THD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 & 2 Lamp Elec. T8

SO*

HI*

 

 

 

 

 

 

1-4 Lamp Elec. T8

O4*

H4*

 

 

 

 

 

 

(8' Unit Only)

 

 

 

 

 

 

 

 

 

LOL T8 Dimming

PS*

 

 

 

 

 

 

 

*Instant Start Standard

 

 

 

Options/Accessories

CANOPY SPACER: Spacer suspends fixture approximately 1 1/2" from surface.

Order Catalog Number: AC1 CSP.

STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.

Order Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").

When stem mounting two or four lamp fixtures in continuous rows, umits must be coupled with nuts and bolts (by others) at end of fixture. Stem and canopy sets not recommended for three lamp fixtures. Other lengths are available. Consult factory.

ELECTRICAL/WIRING OPTIONS: Consult factory.

FUSING: Internal fast-blow fusing. SUFFIX: GLR.

Internal slow-blow fusing. SUFFIX: GMF.

Specifications (continued)

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.

FINISH: Chassis exterior–white baked polyester enamel. Cavity– white baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

LENS: One-piece extruded virgin acrylic prismatic bottom and side walls.

END CAPS: Injection molded catadioptic end caps separate from lens.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W. UL and ULc Listed.

Specifications

PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .74. To reduce glare the VCP shall be not less than 48 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 683 footlamberts To prevent veiling reflections, luminaire output in the 30°-90° zone shall not be less than 64.1%.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier WA Series 232 dimensions Photometry, Options/Accessories, Specifications continued, Model No. WA4A232120SO, Type