Lightolier XP432 Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications

Models: XA432 XP432

1 2
Download 2 pages 17.24 Kb
Page 2
Image 2
Page 2 of 2

XP/XA 2' x 4' Lens Recessed Fluorescent XP/XA432

Page 2 of 2

Static, Flat Steel or Regressed Aluminum Lens Frame, 4 Lamp, T8

Photometry

Model No. XP2GVA432120O4

LER = FL - 74.3 IW - 112 BF - 0.88

Comparative yearly lighting energy cost per 1000 lumens = $3.23

 

25.0030.0

41.0050.0

70.0084.0

83.0100.0

00.0 000.0

83.0100.0

83.0%

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

91

87

84

82

79

77

78

76

74

ratio

2

83

76

71

72

68

64

69

66

63

3

76

68

61

64

59

55

62

57

54

 

cavity

4

70

60

53

57

51

47

55

50

46

5

64

54

47

51

45

41

50

45

40

room

6

60

49

42

47

41

36

45

40

36

7

55

44

37

42

36

32

41

36

32

 

8

52

41

34

39

33

29

38

32

28

 

9

48

37

31

36

30

26

35

30

26

 

10

45

34

28

33

27

23

32

27

23

visual comfort probability

(rated lumens per lamp 2850.)

 

 

 

 

 

 

room size

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

 

54

59

67

76

 

 

53

57

63

72

20

30

 

 

 

46

51

57

64

 

 

47

50

54

61

20

40

 

 

 

41

45

51

57

 

 

43

46

49

53

20

60

 

 

 

37

41

45

51

 

 

39

42

45

49

30

20

 

 

 

56

60

65

73

 

 

55

59

63

71

30

30

 

 

 

47

51

55

62

 

 

48

51

54

59

30

40

 

 

 

42

45

49

54

 

 

43

46

49

52

30

60

 

 

 

37

41

43

48

 

 

39

42

44

47

30

80

 

 

lengthwise

35

38

40

44

 

crosswise

37

40

41

44

40

40

 

 

43

46

50

53

 

45

47

49

52

40

20

 

 

 

58

62

67

72

 

 

57

61

65

71

40

30

 

 

luminaries

49

53

56

61

 

luminaries

49

53

55

59

40

60

 

 

38

41

43

47

 

40

43

44

47

40

80

 

 

 

35

38

39

43

 

 

38

40

41

44

40

100

 

 

 

34

36

37

40

 

 

37

39

39

42

60

30

 

 

 

50

54

57

62

 

 

50

54

56

60

60

40

 

 

 

44

48

50

54

 

 

45

48

50

53

60

60

 

 

 

39

42

43

47

 

 

41

43

44

47

 

 

 

60

80

 

 

 

35

38

39

43

 

 

38

40

41

44

60

100

 

 

 

34

36

37

40

 

 

36

38

39

41

100

40

 

 

 

47

50

53

57

 

 

48

51

52

55

100

60

 

 

 

42

44

46

49

 

 

43

45

46

49

100

80

 

 

 

38

40

41

44

 

 

40

42

43

45

100

100

 

 

 

36

37

38

41

 

 

38

40

40

41

Ordering Information

Explanation of Catalog Number. Example: XP2GVA232120SOGLR

 

 

 

 

2

 

 

 

 

 

 

XP = Recessed

Fixture

 

Fluorescent

Width

 

with Flat Steel

 

 

 

Lens Frame

 

 

XA = Recessed

 

 

 

Fluorescent

 

 

 

with Regressed

 

 

 

Aluminum

 

 

 

Lens Frame

 

 

 

 

 

 

 

 

VA

 

 

4

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling Type:

 

 

 

 

Lamp Quantity:

Lamp Fixture

G =

Grid (lay-in)

 

 

 

 

 

(By others)

Length:

 

 

T-bar

 

 

 

 

 

4 = 4-Lamp

32=T8,

F =

Flanged

Lens Shielding

 

 

 

 

4' Length

 

 

(overlap)

 

 

 

 

 

 

 

 

Z spline and

 

Type:

 

 

 

 

 

 

 

 

VA = Virgin Acrylic

 

 

 

 

 

 

 

 

plaster

 

 

 

 

 

 

 

 

 

 

frame

(standard) see

options and

 

 

consult factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

Options:

 

Add appropriate

120 or 277

 

 

suffix to catalog

 

 

 

 

 

 

 

 

 

 

 

no, ie: (GLR)

 

 

 

 

 

 

 

 

 

Ballast:

 

 

<20THD

<10THD

2-2 Lamp Elec. (T8)

SO*

HI*

1-4 Lamp Elec. (T8)

O4*

H4*

LOL Dimming (T8)

PS

 

*Instant Start Standard

 

 

Other dimming options. Consult factory.

Options/Accessories

Special Lens: Substitute VI for .125" nominal pattern. For other lenses, consult factory.

Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog number: ACPX CSP. Electrical Wiring Options: Consult factory.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture:

Suffix: R. One per ballast: Suffix: B.

Drywall Kit: Order Catalog Number: FK92x4 (Request Folio OA30-10).

Specifications (continued)

Lens: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel edge. .095" nominal thickness (similar to pattern 12).

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Specifications

Performance: In an installation of 4 lamps 32 W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .87. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 70%.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for added strength and rigidity with all edges turned over for safe handling. Lens frames—(XP) flat full-size steel frame, (XA) regressed full-size aluminum frame.

Finish: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

Job Information

Type:

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0303

Section1A/Folio F70-12

Page 2
Image 2
Lightolier XP432, XA432 Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications continued, Type