Lincoln 3270 manual Lincoln, Ventilation Requirements, Warranty, Global

Models: 3270

1 4
Download 4 pages 43 Kb
Page 2
Image 2
Lincoln™

GlobalLincoln

Global

Ventilation Requirements:

Ventilation is required. Local codes prevail. These are the “authority having jurisdiction” as stated by the National Fire Protection Association, Inc. in NFPA 96-1994. Consult the Impinger® 3255/3270 Installation and Operations Manual for ventilation recommendations.

Warranty:

All 3200 series Impinger® ovens installed in the United States and Canada come with a two (2) year parts and labor warranty starting from the date of start-up/check-out. All ovens installed in locations other than the US and Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/ check-out. Start-up/check-out must occur within eighteen (18) months of date of manufacture.

General Information 3255 Natural Gas Ovens:

 

Burner Capacity

 

 

 

 

Gas Supply Pressure

Gas Pipe

 

Voltage

Hertz

Phase

Amps

Inches, Water

 

BTU/hr (MAX)

Size (NPT)

 

 

 

 

 

Column

 

 

 

 

 

 

 

Single Oven

145,000

120

60

1

7

8”-14”

1”

 

 

 

 

 

 

 

 

Double Stack

290,000

120

60

1

14

8”-14”

1¼”

 

 

 

 

 

 

 

 

Triple Stack

435,000

120

60

1

21

8”-14”

1½”

General Information 3255 Propane (LP) Gas Ovens:

 

Burner Capacity

 

 

 

 

Gas Supply Pressure

Gas Pipe

 

Voltage

Hertz

Phase

Amps

Inches, Water

 

BTU/hr (MAX)

Size (NPT)

 

 

 

 

 

Column

 

 

 

 

 

 

 

Single Oven

145,000

120

60

1

7

11.5”-14”

¾”

 

 

 

 

 

 

 

 

Double Stack

290,000

120

60

1

14

11.5”-14”

1”

 

 

 

 

 

 

 

 

Triple Stack

435,000

120

60

1

21

11.5”-14”

1¼”

General Information 3270 Natural Gas Ovens:

 

Burner Capacity

 

 

 

 

Gas Supply Pressure

Gas Pipe

 

Voltage

Hertz

Phase

Amps

Inches, Water

 

BTU/hr (MAX)

Size (NPT)

 

 

 

 

 

Column

 

 

 

 

 

 

 

Single Oven

160,000

120

60

1

14

8”-14”

1”

 

 

 

 

 

 

 

 

Double Stack

320,000

120

60

1

28

8”-14”

1¼”

 

 

 

 

 

 

 

 

Triple Stack

480,000

120

60

1

42

8”-14”

1½”

General Information 3270 Propane (LP) Gas Ovens:

 

Burner Capacity

 

 

 

 

Gas Supply Pressure

Gas Pipe

 

Voltage

Hertz

Phase

Amps

Inches, Water

 

BTU/hr (MAX)

Size (NPT)

 

 

 

 

 

Column

 

 

 

 

 

 

 

Single Oven

160,000

120

60

1

14

11.5”-14”

¾”

 

 

 

 

 

 

 

 

Double Stack

320,000

120

60

1

28

11.5”-14”

1”

 

 

 

 

 

 

 

 

Triple Stack

480,000

120

60

1

42

11.5”-14”

1¼”