Download 32 pages 18.93 Kb
Page 11
Image 11

4

INSTALLATION

4

 

 

 

FOR LOWEST RATED VOLTAGE : H2 CONNECTED

FOR HIGHEST RATED VOLTAGE : H3 CONNECTED

LEAD H1

(DO NOT REMOVE)

INPUT LEADS

L1 & L2

BACK VIEW OF LINE SWITCH

FIGURE A.1 Reconnect Leads

OUTPUT CONNECTIONS

ELECTRODE/GAS OUTLET

RECEPTACLE

WORK CABLE & CLAMP

FIGURE A.2 Location of Output Connections

CONNECTIONS FOR TIG (GTAW) WELDING

TIG TORCH CONNECTION

Refer to Included Equipment in the Operation Section of this manual for TIG welding equipment which is included with the Square Wave TIG 175.

A TIG welding torch with cable and connector is sup- plied with the welder. Turn the Power Switch “OFF”. Connect the torch cable quick connect plug into the

Electrode/Gas Output Receptacle on the front of the welder and turn it clockwise until it is tight. This is a quick connect terminal and also provides the gas con- nection for the shielding gas to the torch.

WARNING

To avoid receiving a high frequency shock, keep the TIG torch and cables in good condition.

__________________________________________

WORK CABLE CONNECTION

A work cable with attached work clamp is factory con- nected to the Square Wave TIG 175. To minimize high frequency interference, refer to Machine Grounding and High Frequency Interference Protection section of this manual for the proper procedure on grounding the work clamp and work piece.

SHIELDING GAS CONNECTION

An adjustable gas pressure regulator and flow gage is supplied with the Square Wave TIG 175. Obtain the necessary inert shielding gas (usually argon). Connect the cylinder of gas with the pressure regulator and flow gage. Install the gas hose between the regu- lator and gas inlet (located on the rear of the welder). The gas inlet has a 5/16-18 right hand female thread; CGA #032.

WARNING

CYLINDER could explode if damaged.

•Keep cylinder upright and chained to a support.

•Keep cylinder away from areas where it could be damaged.

•Never allow the torch to touch the cylinder.

•Keep cylinder away from live electrical circuits.

•Maximum inlet pressure 150 psi.

___________________________________________

The optional undercarriage features a pivoting platform that simplifies loading and unloading of gas cylinders. A cylinder is loaded by leaning it slightly sideways and rolling it toward the platform. The cylinder’s weight will push the platform downward against the floor, forming a ramp. At this point, the cylinder may be rolled up the platform into its final position. Secure the cylinder in place with the provided chain. Unload by following these steps in reverse.

SQUARE WAVE TIG 175