0002

0002

INSTR,INST,AE1 MECH/ELEC

Linear P/N: 213071 B

Material: 20 Lb. Mead Bond

Size: 8.500 x 11.000"

Ink: Black

Scale: 1-1

Back Side 2 of 2

5. CONNECT WIRING 6. OPTIONAL MODEM INSTALLATION 7. OPTIONAL POSTAL LOCK INSTALLATION8. PROGRAM SYSTEM 9. ADJUST SPEAKER VOLUME & TESTING LINEAR LIMITED WARRANTY

This Linear product is warranted against defects in material and workmanship for twelve

(12) months. The Warranty Expiration Date is labeled on the product. This warranty

extends only to wholesale customers who buy direct from Linear or through Linear’s

normal distribution channels. Linear does not warrant this product to consumers.

Consumers should inquire from their selling dealer as to the nature of the dealer’s

warranty, if any. There are no obligations or liabilities on the part of Linear

Corporation for consequential damages arising out of or in connection with use

or performance of this product or other indirect damages with respect to loss of

property, revenue, or profit, or cost of removal, installation, or reinstallation. All

implied warranties, including implied warranties for merchantability and implied

warranties for fitness, are valid only until Warranty Expiration Date as labeled on the

product. This Linear Corporation Warranty is in lieu of all other warranties express

or implied.

All products returned for warranty service require a Return Product Authorization

Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and

other important details.

IMPORTANT !!!

Linear radio controls provide a reliable communications link and fill an important need

in portable wireless signaling. However, there are some limitations which must be

observed.

For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15devices. As such, they have limited transmitter power and therefore limited range.A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signalsthat occur on or near their operating frequencies, regardless of code settings. Changes or modifications to the device may void FCC compliance.Infrequently used radio links should be tested regularly to protect against undetected interference or fault.A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor ordealer, and these facts should be communicated to the ultimate users.Copyright © 1999 Linear Corporation 213071 B

REFER TO THE AM/II INSTALLATION & PROGRAMMING

INSTRUCTIONS FOR DETAILS ON WIRING POWER, EARTH

GROUND, REMOTE DEVICES, ANTENNA, CONTROL INPUTS AND

RELAY OUTPUTS TO THE AM/II

RELAY OUTPUT

TO ACCESS

DEVICE

POWER INPUT

TO TRANSFORMER

EARTH

GROUND

CONNECTION

USE LOWER

WIRING HOLE

IF MODEM IS

GOING TO BE

INSTALLED

TELEPHONE

LINE (USE

MODULAR

JACK OR

TERMINALS)

CONNECT UNITS
WITH THE MODEL
A2M MODEM CABLE
ATTACH MODEMWITH VELCRO ® STRIPS
CONNECT MODEM
TRANSFORMER
POWER CABLE
AND SLIDE MODEM
POWER SWITCH TO "1"
CONNECT
INCOMING
TELEPHONE
LINE TO THE
MODEM'S
"LINE" JACK
USE THE TELEPHONE CABLE
SUPPLIED WITH THE MODEM TO
CONNECT BETWEEN THE
MODEM'S "PHONE" JACK AND THE
AE-1 TELEPHONE LINE JACK
NOTE: SEPARATE PHONE LINES ARE
RECOMMENDED FOR THE MODEM AND AE-1.
ONE PHONE LINE CAN BE USED AS SHOWN
ALTHOUGH THE ENTRY SYSTEM IS
UNAVAILABLE WHILE MODEM IS ON-LINE.
1
2
3
REMOVE THE TWO NUTS
AND THE POSTAL LOCK
BARRIER PLATE
BARRIER PLATE
BEND UP TABS ON
THE HOLE PLUG AND
REMOVE THE PLUG
INSTALL THE POSTAL
LOCK USING FOUR
10-32 NUTS
VERIFY THAT THE LOCK
STRIKE ACTIVATES THE
MICRO SWITCH
AREA 07TELEPHONE ENTRY NUMBERS
7.1
7.2
7.3
7.4
7.5
Enter Directory Code
Directory Code: 0000
Enter Telephone Number
Telephone#: ************
Enter Tenant Name
Extended Talk Time
Yes No
Delete Directory Entry
Directory Code: 0000
RELAY SETUPAREA 21
21.1
21.2
21.3
21.4
21.5
21.6
Which Relay to Program.
CH-A CH-B CH-C CH-D
Select Operation:
Control Shunt Alarm Obstacle CCTV
Select Timing Mode:
Time Pulse Toggle Latch
Enter Activation Time:
Time in seconds: 00000
21.7
21.8
Assign Time Zone [1]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
21.9
21.10
21.11
Enter Channel Name
Assign Telephone Digit
None 1 2 3 4 5 6 7 8 9
Channel Control
Normal Activate LockOpen LockClosed
Assign Time Zone [2]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [3]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [4]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
TELEPHONE ENTRY SETUPAREA 27
27.1
27.2
27.3
27.4
27.6
Directory Code Length
1 2 3 4
Directory Begins At
Beginning(A) Middle(M)
PBX Dialing Digit
Off 9 8 7 6 5 4 3 2 1 0
27.7
27.8
27.9
27.10
Sort Directory Names
Yes No
Edit Display Messages
Message Number: 00
Set Talk Time
Talk Time Seconds: 060
Edit Display Message
Max Directory Entries
Maximum Entries: 00000
Delete All Tlph. Entries
Yes No
27.5
27.11
Assign Postal Key Door
CH-A CH-B CH-C CH-D
Adjust Hybrid Level
Press OK To Start/Stop
INSTALLERS OF AE-1 SYSTEMS SHOULD FAMILIARIZE THEMSELVES WITH THE AM/II SYSTEM BY READING THE ENTIRE AM/II INSTALLATION & PROGRAMMING INSTRUCTIONS. PROGRAM AREAS SPECIFIC TO THE AE-1 ARE AREAS 07 & 27. AREA 21 HAS TWO OPTIONS FOR THE AE-1. PROGRAMMING WITH A PERSONAL COMPUTER IS RECOMMENDED, ESPECIALLY FOR ENTERING THE TENANT NAMES.
27.12
Display Briteness
Dim Low Med High
27.13
Priority Access ABCD
0 = No 1 = Yes 0000
5
4
3
2
1
REMOVETEST JUMPER
6
PRESS # TO VIEW DIRECTORY AND ENTER CODE TO DIAL A TEST PHONE NUMBERADJUST THE SPEAKER VOLUME AND DISPLAY CONTRAST TO SUIT THE ENVRONMENT THE UNIT IS MOUNTED INHAVE TESTING PARTY PRESS ASSIGNED TELEPHONE DIGIT (DEFAULT IS 9) TO GRANT ACCESSVERIFY THAT THE PROPER RELAY ACTIVATES AND THAT THE ACCESS DOOR STRIKE OR GATE CONTROL ACTIVATESREPLACE THE TEST JUMPER, LOCK THE CABINET AND INSTRUCT FACILITY MANAGER ON SYSTEM USE