WIRING EXAMPLES | SELECT OPTIONS |
|
| LOW BAT |
| RECEIVER |
|
| MODEL | EXAMPLE RELAY |
| |||||||
|
| STAT |
|
|
|
|
|
|
|
|
|
|
| N.C. | ||
GND | +12V | CH1 | CH2 | CH3 | CH4 | GND | CH5 | CH6 | CH7 | CH8 | GND |
| COM | |||
TO +12 VOLTS | N.O. | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 12 VOLT |
| |
|
|
|
|
|
|
|
|
| EXAMPLE | RELAY |
| |||||
|
|
|
|
|
|
|
|
| TO RECEIVER |
| ||||||
|
|
|
|
|
|
|
|
| CONTROL PANEL |
| ||||||
|
|
|
|
|
|
|
|
| OUTPUT |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| 1N4001 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| DIODE |
|
SET OUTPUT JUMPERS | CUT STATUS JUMPERS FOR | |
FOR EACH CHANNEL USED | ANY CHANNELS THAT REQUIRE | |
| STATUS TRANSMISSION MONITORING | |
MOMENTARY OUTPUT | USE SMALL CUTTERS | |
JUMPER IN THIS POSITION | ||
TO CUT JUMPERS | ||
(FACTORY SETTING) CAUSES | ||
| ||
A MOMENTARY 1 SECOND MINIMUM |
| |
OUTPUT WITH EACH ACTIVATION |
|
| EXAMPLE BEEPER | ||||
TO RECEIVER |
|
|
|
| TO |
|
|
|
| ||
|
|
|
| ||
OUTPUT |
|
|
|
| +12 VOLTS |
|
|
|
| ||
|
|
|
|
|
|
| PIEZO BEEPER | ||||
NOTES: |
| EXAMPLE L.E.D. | |||
1. ZONES ARE NORMALLY OPEN |
TOGGLE OUTPUT
JUMPER IN THIS POSITION CAUSES A TOGGLE OUTPUT, EACH ACTIVATION WILL CAUSE THE OUTPUT TO SWITCH FROM OFF TO ON, OR, ON TO OFF
LATCHING OUTPUT
IF NORMALLY CLOSED OUTPUTS ARE REQUIRED, REMOVE THE OUTPUT POLARITY JUMPER
|
|
|
|
|
|
|
|
| WITH | TO RECEIVER | |
|
|
|
|
|
|
|
|
|
| OUTPUT | |
CONTROL | NEGATIVE | +12AUX | ZONE 1 | COM | ZONE 2 | ZONE 3 | COM | ZONE 4 | 2. LOW BATTERY AND STATUS | L.E.D. | |
PANEL | OUTPUTS ARE COMBINED TO | ||||||||||
| |||||||||||
| TRIGGER ZONE 4 AS TROUBLE | TO | |||||||||
|
| 1K OHM |
+12 VOLTS
JUMPER REMOVED CAUSES OUTPUT TO LATCH UNTIL RESET BY A RESTORE TRANSMISSION
ADDING TRANSMITTERS | REVIEWING MEMORY |
1
REMOVE THE PROGRAM JUMPER, THE CHANNEL DISPLAY SHOWS "P"
3
YOU HAVE 5 SECONDS TO ACTIVATE THE TRANSMITTER, THE ALARM LED WILL BLINK
2 | 1 | 2 |
BRIEFLY PRESS THE BUTTON FOR THE | REMOVE THE PROGRAM JUMPER, | PRESS AND HOLD THE BUTTON FOR THE | |||
CHANNEL THAT THE TRANSMITTER | THE CHANNEL DISPLAY SHOWS "P" | CHANNEL TO REVIEW UNTIL THE ALARM | |||
IS GOING TO BE ADDED INTO, THE CHANNEL |
|
|
| LED STARTS TO BLINK, THEN RELEASE | |
NUMBER SHOWS ON THE DISPLAY |
|
|
| THE CHANNEL BUTTON | |
4 |
|
|
|
|
|
AFTER THE TRANSMITTER IS ENTERED, OR AFTER 5 |
| 3 |
|
|
|
|
|
|
| ||
SECONDS, THE CHANNEL DISPLAY WILL RETURN TO "P" |
|
|
| COUNT THE NUMBER OF TIMES THE ALARM LED | |
REPEAT STEPS 2 & 3 FOR ADDITIONAL TRANSMITTERS |
|
|
|
| |
|
|
|
| BLINKS, THIS IS THE NUMBER OF TRANSMITTERS | |
(UP TO 32 TOTAL, WITH ANY MIX OF CHANNELS) THEN |
|
|
|
| PROGRAMMED INTO THE CHANNEL |
REPLACE PROGRAM JUMPER WHEN FINISHED |
|
|
|
| REPEAT STEPS 2 & 3 TO REVIEW OTHER CHANNELS |
|
|
|
| ||
|
|
|
|
|
NOTE: ON
BUTTON HAS A UNIQUE CODE, AND IS ADDED TO THEREPLACE THE PROGRAM JUMPER WHEN FINISHED RECEIVER SEPARATELY, INTO ANY CHANNEL
REMOVING TRANSMITTERS
1 | 2 |
SYSTEM OPERATION
THE CENTER BAR OF THE CHANNEL DISPLAY WILL BLINK WHILE THE RECEIVER IS IDLE
THE DECIMAL POINT WILL LIGHT WHEN ANY INCOMING RADIO SIGNALS ARE PRESENT
REMOVE THE PROGRAM JUMPER, | PRESS AND HOLD THE CHANNEL BUTTON FOR | ||
THE CHANNEL DISPLAY SHOWS "P" | THE CHANNEL TO ERASE, CONTINUE HOLDING | ||
|
|
| DOWN THE BUTTON WHILE THE ALARM LED |
|
|
| COUNTS THE NUMBER OF TRANSMITTERS |
|
|
| KEEP HOLDING THE BUTTON DOWN |
3 |
|
| THE DISPLAY WILL CONTINUE TO SHOW THE CHANNEL NUMBER |
|
|
| KEEP HOLDING DOWN THE CHANNEL BUTTON UNTIL THE ALARM |
|
|
| |
|
|
| LED FLASHES TWICE, SIGNALING THE CHANNEL HAS BEEN |
|
|
| ERASED |
|
|
| REPEAT STEPS 2 & 3 TO ERASE OTHER CHANNELS |
|
|
| REPLACE THE PROGRAM JUMPER WHEN FINISHED |
ALARM STATUS
LOW BATT
WHEN ANY CHANNELS ARE IN ALARM, OR HAVE ANY SUPERVISORY CONDITIONS, THE CHANNEL NUMBER(S) WILL SHOW ON THE CHANNEL DISPLAY, ADVANCING IN ASCENDING ORDER
AS EACH CHANNEL NUMBER IS DISPLAYED, ITS CONDITION IS SHOWN ON THE THREE INDICATORS (ALARM, STATUS, OR LOW BATTERY)
WHEN ALL OUTPUTS ARE RESTORED
| SUPERVISORY CONDITIONS |
| STATUS MONITORING |
| IF STATUS MONITORING IS ENABLED FOR A RECEIVER CHANNEL |
ALARM | (BY CUTTING ITS STATUS JUMPER), A TRANSMITTER SENDING |
STATUS | STATUS REPORTS MUST BE PROGRAMMED INTO THAT CHANNEL |
| |
LOW BATT | IF STATUS REPORTS ARE NOT RECEIVED FOR EIGHT HOURS, |
| |
| THE CHANNEL NUMBER WILL BE DISPLAYED, THE STATUS |
| INDICATOR WILL LIGHT, AND THE STATUS OUTPUT WILL ACTIVATE |
| NOTE: IF STATUS MONITORING IS ENABLED FOR A CHANNEL, |
| ONLY PROGRAM ONE STATUS REPORTING TRANSMITTER |
| INTO THAT CHANNEL |
IF A LOW BATTERY REPORT IS RECEIVED FROM A TRANSMITTER, ITS CHANNEL NUMBER WILL BE DISPLAYED, THE LOW BATT
ALARM INDICATOR WILL LIGHT, AND THE LOW BATTERY OUTPUT WILL ACTIVATE
STATUS
LOW BATT THE INDICATION WILL CONTINUE AND THE OUTPUT WILL STAY ACTIVATED UNTIL THE TRANSMITTER'S BATTERY IS REPLACED
LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2002 Linear Corporation | 215633 E |