PRODUCT DESCRIPTION

BBU

 

PRODUCT DESCRIPTION

FEATURES

 

 

The Model BBU Battery Backup Unit is designed to provide DC power for Linear’s

 

 

 

 

 

Model LDCO800 Garage Door Operator during AC power outages.

INTERNAL SOUNDER

 

BATTERY

 

The BBU contains two rechargeable batteries that are maintained and charged by

3 BEEPS EVERY MINUTE = FAILED BATTERY TEST

 

 

 

 

 

the LDCO800 operator. If the installation’s AC line power is interrupted, the BBU will

 

 

BACKUP

 

power the operator for up to 24 hours. The duration of the operator’s battery backup

MOUNTING TABS (3)

 

 

will depend on the number of times the garage door is cycled without AC power. The

 

 

UNIT

 

 

 

 

batteries will be fully recharged within 48 hours after AC power is restored.

 

 

Installation Instructions

 

The BBU contains an internal sounder to indicate the current status of the battery

 

 

 

unit. The unit regularly performs a self-check routine while AC power is present. If the

MOUNTING SCREWS (3)

 

 

 

batteries test low or dead, the unit will sound three beeps every minute to indicate

 

 

For Use with Model LDCO800

 

that service is required.

 

 

Garage Door Operators

 

Every LDCO800 is compatible with the BBU. The operator now has three pre-drilled

WIRING HARNESS

 

 

 

holes in the chassis to mount the BBU and a connector for the BBU on the controller

 

 

 

 

 

 

 

 

board.

 

 

 

 

 

For retrofi t installations, replace the LDCO800 operator’s controller board with a newer

 

 

 

USA & Canada (800) 421-1587 & (800) 392-0123

 

Model HAE00061 controller board that has the BBU connector. Refer to the mounting

 

 

 

(760) 438-7000 - Toll Free FAX (800) 468-1340

 

template supplied to drill three holes in the chassis of the operator to mount the BBU.

 

 

 

www.linearcorp.com

 

 

 

 

 

 

 

 

REMOVE OPERATOR COVER

 

INSTALL BATTERY BACKUP UNIT IN OPERATOR

CONNECT POWER WIRES

 

1

UNPLUG THE OPERATOR BEFORE PROCEEDING !!!

USE THE THREE SCREWS TO ATTACH

REMOVE JUMPER PLUG FROM

 

 

 

 

THE BATTERY BACKUP UNIT TO

CONTROLLER BOARD'S 3-WIRE HARNESS

 

 

 

 

THE OPERATOR BASE PLATE

(SAVE THE JUMPER PLUG)

 

 

 

 

FOR RETROFIT INSTALLATIONS,

 

 

 

 

 

REFER TO MOUNTING TEMPLATE

 

 

 

 

 

 

CONNECT THE 3-WIRE HARNESS TO

2

 

 

 

THE BATTERY BACKUP 3-WIRE HARNESS

 

 

 

 

 

LOOSEN THE

 

 

 

 

FOUR COVER

 

 

JUMPER PLUG

 

SCREWS

 

 

NOTE: THE JUMPER PLUG MUST

 

 

 

 

 

 

 

 

3

 

REMAIN IN PLACE UNTIL THE

 

 

 

 

BATTERY BACKUP

 

 

 

REMOVE THE

 

UNIT IS INSTALLED

 

 

 

OPERATOR'S

THE BATTERY BACKUP

 

 

 

 

COVER

UNIT CAN BE INSTALLED

 

 

 

 

 

WHILE THE OPERATOR IS

 

 

 

 

 

MOUNTED OR WHILE THE

 

 

 

 

 

OPERATOR IS ON THE FLOOR

 

 

REPLACE OPERATOR COVER

 

TEST OPERATOR

LINEAR LIMITED WARRANTY

 

 

 

 

 

This Linear product is warranted to the original consumer against defects in material and workmanship for 1 year. Linear will repair,

 

 

 

 

or at its option, replace, any device that it finds requires service under this warranty, and will return the repaired or replaced device

 

 

 

1 BE SURE TO LET THE BATTERY

to the consumer at Linear’s cost. Devices must be sent to Linear for service at owner’s expense. This warranty does not apply to

1

REPLACE THE

2

damage to the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or due to failure to follow

BACKUP UNIT CHARGE FOR

Seller’s instructions, or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental,

 

OPERATOR'S

TIGHTEN THE FOUR

48 HOURS BEFORE TESTING

compensatory, punitive, consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive.

 

COVER SCREWS

 

COVER

 

Some states do not allow the exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may

 

 

 

 

 

 

 

not apply to you. Any warranties implied by law are limited to the time periods set forth above. Some states do not allow limitations on

 

 

 

 

how long an implied warranty lasts, so the above limitation may not apply to you.This warranty gives you specific legal rights, and you

 

 

 

 

may also have other rights which vary from state to state.

 

 

 

 

 

For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this

 

 

 

 

warranty, save your proof of purchase and send a copy with equipment should repair be required. All products returned for warranty

 

 

 

 

service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA#

 

 

 

 

and other important details.

 

 

 

 

2

This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with

 

 

 

UNPLUG THE

the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply

 

 

 

with the limits for a Class B computing device in accordance with Part 15 of FCC Rules, which are designed to provide reasonable

 

 

 

OPERATOR

 

 

 

protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a

 

 

 

 

 

 

 

 

particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning

 

 

 

3 TEST RUN THE OPERATOR

the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

 

 

 

• Relocate the Console away from the TV/radio receiver.

 

 

 

 

(THE OPERATOR'S LAMP WILL NOT LIGHT)

 

 

 

 

• Plug the Console into a different wall outlet so that the Console is on a different branch circuit.

 

 

 

 

 

 

 

 

 

4 PLUG THE OPERATOR BACK IN

Re-orient the TV/radio antenna.

 

 

 

 

• If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.

 

 

 

 