6. SET RECEIVER SWITCHES

7. CONNECT POWER AND OUTPUTS

8. MOUNT ANTENNA AND ROUTE CABLE

 

 

 

 

OPTION SWITCH
SWITCH #

 

CHANNEL #

 

SELECTION

 

 

SWITCH 1

 

CH 1

 

OFF = NO STATUS REPORTS REQUIRED FROM TX CHANNEL 1

 

 

ON = STATUS REPORTS ARE REQUIRED FROM TX CHANNEL 1

 

 

 

 

SWITCH 2

 

CH 2

 

OFF = NO STATUS REPORTS REQUIRED FROM TX CHANNEL 2

 

 

ON = STATUS REPORTS ARE REQUIRED FROM TX CHANNEL 2

 

 

 

 

SWITCH 3

 

CH 3

 

OFF = NO STATUS REPORTS REQUIRED FROM TX CHANNEL 3

 

 

ON = STATUS REPORTS ARE REQUIRED FROM TX CHANNEL 3

 

 

 

 

SWITCH 4

 

CH 4

 

OFF = NO STATUS REPORTS REQUIRED FROM TX CHANNEL 4

 

 

ON = STATUS REPORTS ARE REQUIRED FROM TX CHANNEL 4

 

 

 

 

 

 

SET SWITCHES 1 -4 TO SELECT THE CHANNELS THAT WILL

 

 

REQUIRE STATUS REPORTS FROM THE TRANSMITTER(S)

 

 

 

 

 

SYSTEM CODE SWITCHESSET SYSTEM CODE SWITCHES A & BTO MATCH SYSTEM CODE SWITCHESA & B IN THE TRANSMITTER
USE 18-24 AWG WIRE
TO CONNECT POWER
AND OUTPUTS
ROUTE WIRES THROUGH CASE
STRAIN RELIEF BUSHING BEFORE
CONNECTING TO TERMINALS
GND12+VDCLOWBATSTATUS

N/O

COM

 

N/C

 

N/O

COM

 

N/C

 

N/O

COM

 

N/C

 

N/O

COM

 

N/C

 

 

 

 

 

CH

1

 

 

 

CH

2

 

 

 

CH

3

 

 

 

CH

4

 

USE ANT-1A ANTENNA FOR SHORT RANGE (LESS THAN 1 MILE)

APPLICATIONS
ANT-1AANTENNACON-180A + CON-90AANGLE CONNECTOR
CON-180A

STRAIGHT CONNECTOR

SWITCH "A"SWITCH "B"

 

EACH RELAY OUTPUT WILL SWITCHUP TO 1 AMP @ 32 VDC
LOW BATTERY & STATUS

 

 

OUTPUTS WILL SWITCH

 

 

UP TO 50 mA @ 20 VDC

 

WARNING
TO GROUND WHEN ACTIVE

 

 

FROM 12 VOLT, 1/2 AMPTHIS UNIT REQUIRES 12 VDC AT 1/2 AMP.
THE NO-LOAD VOLTAGE OF THE SUPPLY
POWER SOURCE
MUST NOT EXCEED 17.5 VDC OR DAMAGE
RECEIVER CURRENT:
<30 mA STANDBYTO THE UNIT WILL OCCUR!

 

 

<190 mA WITH ALL RELAYS ENERGIZED

 

USE 3-FOOT LONG ANT-2 ANTENNA FOR LONGERRANGE APPLICATIONS OR DIFFICULTINSTALLATIONSMOUNT ANTENNAS AS HIGH AS POSSIBLE(A METAL MOUNTING POLE IS RECOMMENDED)AN 18-FOOT RG-58 CABLE IS SUPPLIED WITH THEANT-2 KIT. UP TO 50 FEET OF RG-58 CAN BE USED.USE RG-8 FOR UP TO 100-FOOT CABLE RUNS.

TO UNIT

9. TEST SYSTEM

10. COMPLETE INSTALLATION

LINEAR LIMITED WARRANTY

SLIDE BOARD INTO
CASE IN THE 3RD
SLOT UP

WARNING

NEVER CONNECT THE TRANSMITTER AND RECEIVER ANTENNA CONNECTORS DIRECTLY TO EACH OTHER. MAJOR DAMAGE TO BOTH UNITS WILL OCCUR!

INSTALL AND SETUP THE COMPANION UNIT AS DESCRIBED IN ITS INSTALLATION INSTRUCTIONS

SECURE END PLATE BY

INSTALLING THE FOUR CASE SCREWS

INSTALL THE TWO REMAINING MOUNTING SCREWS

This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of

Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express or

TRANSMITTER
RECEIVER
APPLY POWER AND TRIGGER THE

 

TRANSMITTER'S INPUT

 

THE TRANSMIT INDICATOR
THE RECEIVER'S SIGNAL
SHOULD LIGHT WHEN THE
INDICATOR SHOULD LIGHT AND
TRANSMITTER IS TRIGGERED
OUTPUT SHOULD ACTIVATE
IF SYSTEM FAILS TEST, CHECK POWER, SWITCHSETTINGS AND ANTENNA CONNECTIONS

TIGHTEN WIRING STRAIN

RELIEF BUSHING TOSECURE AND WEATHERPROOF WIRINGTEST SYSTEM AGAIN AFTERCOMPLETING INSTALLATION

implied.

All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

IMPORTANT !!!

Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed.

WARNING: THIS PRODUCT IS NOT TO BE USED IN LIFE SAFETY APPLICATIONS. FCC Rules allow unlicensed high-power transmissions at or near the operating frequency of this product which may interfere with, or even disable, normal operation of this radio device.

For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 95 Radio Control devices. As such, they have limited transmitter power and therefore limited range.

A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.

Changes or modifications to the device may void FCC compliance.

Infrequently used radio links should be tested regularly to protect against undetected interference or fault.

A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.

Copyright © 2004 Linear LLC

215194 C