Lochinvar JR-SUB-07 6 - 30 gallon models, Voltage Schedule, 1500, 2000, 2500, 3000, 3500

Models: JR-SUB-07

1 2
Download 2 pages 31.3 Kb
Page 2
Image 2
2 gallon model

Junior Electric Water Heaters Dimensions & Specifications

2 gallon model

Wattage Schedule and Recovery Rates

 

 

 

 

Recovery Rate (GPH @ °F Rise)

Element Wattage 40

50

60

70

80

90 100

E

1500

16

12

10

9

8

7

6

F

2000

21

17

14

12

10

9

8

G

2500

26

21

17

15

13

11

10

H

3000

31

25

21

18

16

14

12

J

3500

36

29

24

21

18

16

14

L

4000

41

33

28

24

21

18

17

K

4500

47

37

31

27

23

21

19

M

5000

52

41

34

30

26

23

21

P

6000

62

50

41

35

31

28

25

6 - 30 gallon models

NOTE: Max wattage @120V is 3000W.

 

VOLTAGE

SCHEDULE

C – 120V 1ø

J – 208V 1ø

A – 240V 1ø

Model

Gal.

 

 

 

 

Shipping
Number

Cap.

A

B

D

E

Weight

JRCOO2E*

2

12-1/4”

10”

13-1/4”

13-1/4”

14

JRC006E

6

16-1/2”

14”

10-1/4”

3”

33

JRC012E

12

27-3/4”

14”

21-1/4”

3”

48

JRC020E

19

24-3/4”

18”

18-1/4”

3”

59

JRC031E

30

30”

22”

23-1/2”

4-1/2”

82

Notes:Standard wattage and voltage: 1500w / 120v. Maximum wattage for 6 and 12 gallon is 3000w. Maximum wattage for 19 and 30 gallon is 6000w. * 2 gallon is available in 1500w / 120v only.

Water connections are 3/4" NPT.

Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900/Fax: 615-547-1000

www.Lochinvar.com

4/08—Printed in U.S.A.

Page 2
Image 2
Lochinvar JR-SUB-07 6 - 30 gallon models, Voltage Schedule, C - 120V 1ø J - 208V 1ø A - 240V 1ø, 1500, 2000, 2500