9
BOILER SYSTEM
1. On new boiler installations, do not pu rge the boiler or space heating system through the water heate r.
During any boiler or space heating system flushing, cleaning, or purging, the water heater should be
isolated to avoid possible attack on the coil by chemical additives.
2. Purge air from boiler/water heater piping.
3. Check system for leaks. Repair as necessary .
ELECTRICAL CONNECTIONS
Install electric wiring in accordance with National Electric Code or the Canadian Electrical Code and local
regulations. See the boiler’s installation manual for wiring diagrams. The Indirect is equipped with an
adjustable temperature control. Once electrical connections are complete, secure the control cover back
in place. AT NO TIME SHOULD WATER HEATER OPERA TION TAKE PLACE WITHOUT THE COVER
ON THE CONTROL.
INSTALLING THEROMSTAT WIRING
1. Remove (4) screws from cover to remove front control panel.
2. Feed 24 volt wire from boiler control through the openin g on the top pan labeled
“thermostat connection. Install female ¼” connectors on the wiring and connect to
the (2) two ¼” spade terminals on the thermostat.
3. Make sure all wiring is safely inside the junction box and reinstall the front
control panel cover.
DANGER
Positively assure all electrical connections are unpowered before a ttempting installation or service of
electrical components or connections of the water heater or building. Lock out all electrical boxes with
padlock once power is turned off.
WARNING
When installed, the water heater must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, and /or the CSA C22.1 Electric
Code. Failure to properly wire electrical connection s to the water heater may result in serious physical
harm. Electrical power may be from more than one so urce. Make sure all power is off before attempting
any electrical work.
WATER TEMPERATURE ADJUSTMENT
WARNING - SCALDING
This water heater can deliv er scalding tempera ture water at any faucet in the system. Be careful
whenever using hot water to avoid scalding injury. By setting the thermostat on this water heater
to obtain an increased water temperature, you may create the potential for scald injury. To protect
against injury, you should install an ASSE approved mixing valve (a device to limit the
temperature of water to protect against scald injury via mixing hot and cold water supply) in the
water system. This valve will reduce point of discharge temperature in branch supply lines. Such
valves are available from the manufacturer of this water heater or a local plumbing supplier.
Please consult with a plumbing professional.