Louisville Tin and Stove 000 BTU Single, Wall, Dual, Specifications, Rough In, BTU/Hr, Fan Kit

Models: 000 TO 50 000 BTU 25

1 2
Download 2 pages 53.83 Kb
Page 2
Image 2
ROUGH IN

Engineered for years of efficient, trouble free service

Featuring 20 gauge aluminized combustion chambers, warranted for 10 years.

Single Wall Furnace models may be equipped with a Rear Register Kit and Grille (40542) allowing warm air to circulate into the adjoin- ing room. Adjustable vent controls air flow.

Fan accessory kit (WFF81)

Optional Night Setback

available for installation on

Thermostat (XL 110 / XL411)

top of furnace to increase

provides economic as well

circulation. Adds only 101/2

as convenient operation.

to height of casing. Fits

 

flush against wall — not

 

recessed. Operates at

 

50 CFM on 115V.

 

 

 

ROUGH IN

Easy installation method reduces installation time to minutes . . . only one man needed. New positive fastening tabs hold grille in place . . . makes installation a snap!

Resettable Blocked Flue Safety Device automatically shuts the unit off in the event of flue blockage or incorrect vent installation.

Free Standing Kit (FSK) allows single wall furnaces to be surface mounted.

 

 

125/8"

 

OPENING

 

 

FOR REAR

81/4"

 

REGISTER

 

MODEL

 

141/4" MIN.

 

 

141/2" MAX.

REAR

 

653/4"

REGISTER

 

 

FRAME

 

 

PLASTER

453/4"

 

 

PLASTER

SPECIFICATIONS NAIL TO STUDS

BTU/Hr. OPENING 7/8" FROM EACH STUD

Rear Register Kit STUD

Continuous Seam-Welded Combustion Chamber constructed of heavy gauge aluminized steel, maximizes heat transfer. Warranted for ten (10) years.

Eliminates cutting holes in wall — ideal for masonry wall installation. For use with ceilings up to 8'6" tall; adds 4-3/4" to unit depth.

4"

Fan Kit4"

PLATE

PLASTER

(vent pipe not included). Weight: 16 lbs.

ROUGH-IN DIMENSIONS

REAR REGISTER OUTLET LOCATION

SPECIFICATIONS

 

Model

Type

Type

BTU/Hr.

Vent

Gas

Finished

Shipping

Rear Register Kit
Fan Kit

 

Number

Control

Gas

Input

Size

Inlet

Dimensions

Weight

Model

Weight

Model

Weight

SINGLE

W251

Bulb

Nat.

25,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

WALL

W255

M. Volt

Nat.

25,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W252

Bulb

L.P.

25,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

 

 

W256

M. Volt

L.P.

25,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

 

W351

Bulb

Nat.

35,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

 

W355

M. Volt

Nat.

35,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

 

W352

Bulb

L.P.

35,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

DUAL

W356

M. Volt

L.P.

35,000

4"

1/2"

161/2" W 68" H 61/2" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W501

Bulb

Nat.

50,000

4"

1/2"

161/2" W 68" H 61/2" D

134 lbs.

N/A

N/A

WFF81

10 lbs.

WALL

W505

M. Volt

Nat.

50,000

4"

1/2"

161/2" W 68" H 61/2" D

134 lbs.

N/A

N/A

WFF81

10 lbs.

 

 

W502

Bulb

L.P.

50,000

4"

1/2"

161/2" W 68" H 61/2" D

134 lbs.

N/A

N/A

WFF81

10 lbs.

 

W506

M. Volt

L.P.

50,000

4"

1/2"

161/2" W 68" H 61/2" D

134 lbs.

N/A

N/A

WFF81

10 lbs.

One or two fan kits may be used on dual-wall furnace.

Form No. GWF 15M 10/05

Page 2
Image 2
Louisville Tin and Stove 000 BTU Single, Wall, Dual, Specifications, Rough In, BTU/Hr, Rear Register Kit, Fan Kit, Inlet