SCALE Remember, there must be some
movement between the boat and the fish
There are ten scale markers
printed on both sides of the X-3's display
to
help determine what the depth
of a target
is. For
example,
if the
depth
range is 0 to 60 feet, then each mark is equal
to six feet. If
the target
(such as a
fish) was next to
the 5th line,
then it is 30 feet deep (5 lines
times six feet=30
feet). To make it easier to use the
depth scale, use
ranges in multiples
often, i.e. 10, 30, 140, etc.
SENSITIVITY/CHAR

c::

•iui

Ii.--.——
12
24
SCALE
MARKERS

1llmm36

48
to develop
the arch. Usually
this means trolling at
very slow
speeds
with
the main engine in gear
at a minimum throttle
setting.
The
depth of the water will affect the size and shape of the fish arch due
to the
cone
angle diameter. For
example, if the cone passes
over a fish in
shallow water,
the
signal displayed
on
the X-3 may not arch at
all, due to
the narrow cone diameter and the resolution
limitations of
the display.
Compared
to a
paper graph,
the X-3 cannot
show as fine detail because
the pixels (dots
on the
screen)
are much larger
than a
paper graph's.
Therefore,
the X-3 cannot show fish arches as well as a
graph.
Very
small fish probably
will not arch at
all, while medium sized
fish
will
show a partial arch, or a shape
similar to an arch, if
they're in deep water
Large fish will arch, but the
sensitivfty must be turned up, especially in
deeper
water There will be times when the sensitivity
cannot be turned
high enough to
get
fish arches because of the heavy
surface clutter,
therrnoclines,
etc.
One of
the best ways to
get
fish arches is to
expand or "zoom" a seg-
ment of the water, for
example
40 to 60 feet. The smaller the
segment the
better the
screen resolution will be.
Then,
turn up
the sensitivity
as high
as possible without getting
too much noise on the
screen.
In medium to
deep water,
this method should work to display
fish arches.
F LOW1
LIMIT J
LOWER LIMIT
To change the lower limit, press
the lower limit desired from 10 feet to
999 feet and then press
the LOWER LIMIT key. The
display will imme-
diately change to the new depth range and display
the new lower limit at
the bottom of the screen.
The lower limit may be changed anytime, even if the AUTO RANGE func-
tion is on. However,
if a lower limit is selected that is less than the depth
of the bottom while the unit is in the AUTO
RANGE mode, it won't
accept
the entry For
example, suppose
the X-3 is in the AUTO RANGE, mode
and the lower limit is 75 feet with the bottom at
60 feet If a new lower
limit of 55 feet were entered on the
keyboard, the X-3 would chirp, and
keep the lower limit
setting of 75 feet.
Figure 6
LILI AUTO.
RANUING ——"OHIO
P1
Figure 22
9 26
PDF compression, OCR, web-optimization with CVISION's PdfCompressor