(DHP2120) ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS

HEAT PUMP TERMINAL CROSS REFERENCE CHART

TABLEAU DE RÉFÉRENCE CROISÉE DE BORNE DE POMPE À CHALEUR TABLA DE REFERENCIA PARA LA TERMINAL DE LA BOMBA DE CALEFACCIÓN

(DHP2120) ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS

HEAT PUMP BRAND

CORRESPONDING TERMINALS

TAPE OFF (NOT USED)

MARQUE DE POMPES

BORNES

RUBAN RETIRÉ

À CHALEUR

CORRESPONDANTES

(NON UTILISÉ)

MARCA DE LA BOMBA

TERMINALES

DESPRENDIMIENTO

DE CALEFACCIÓN

CORRESPONDIENTES

(NO UTILIZADO)

 

E

G

Y

R

O

W2

B

C

L

 

 

 

 

 

 

 

 

 

 

ARCO / Friedrich

X2

G

Y

RC

 

W2

B

C

L

 

 

 

 

 

 

 

 

 

 

ARCO / Snyder General

E

G

Y

R

O

W1

 

C

X

 

 

 

 

 

 

 

 

 

 

BARD

E

G

Y1

R

 

W2

B

X

L

 

 

 

 

 

 

 

 

 

 

BARD, HP, WH, MHP, HPQ

E

G

Y

R

 

W2

W1

X

L

 

 

 

 

 

 

 

 

 

 

BDP / BRYANT

E

G

Y

R

O

W1

 

C

F

 

 

 

 

 

 

 

 

 

 

CARRIER

E

G

Y

R

O

Y1

 

C

L

 

 

 

 

 

 

 

 

 

 

CARRIER 5Q

to W2

G

Y, W1

R

O

W2

 

C

L

 

 

 

 

 

 

 

 

 

 

CARRIER 50Q, QT382

E

G

Y

R

O

W2

 

C

L

 

 

 

 

 

 

 

 

 

 

COLEMAN

 

G

Y

RED

V

W2

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

GE BAY

X2

G

Y

R

O

W

 

B

T

 

 

 

 

 

 

 

 

 

 

HEIL-QUAKER / Whirlpool

 

G

Y

R

O

W

 

B

 

# 1

TYPICAL 24 VOLT, SINGLE-STAGE HEAT PUMPS AND

2-STAGE HEAT / 1-STAGE COOL HEAT PUMP SYSTEMS

WITH NO EMERGENCY HEAT WIRE

Y1

E

G

R

B/O

Y2

W2

C

 

 

 

 

 

 

 

 

**Refer To

 

 

 

 

 

 

 

 

Wiring Note #1

 

 

 

 

 

 

 

 

System

 

 

 

 

 

 

 

 

Common

 

 

 

 

+

-

 

 

 

HEAT

 

 

BLOWER

SYSTEM

REVERSING

AUX.

PUMP

 

 

FAN

XFMR

 

 

VALVE

HEAT

# 2

TYPICAL 24 VOLT, 2-STAGE HEAT / 1-STAGE COOL

HEAT PUMP SYSTEMS

WITH EMERGENCY HEAT WIRE PRESENT

Y1

E

G

R

B/O

Y2

W2

C

 

 

 

 

 

 

 

 

System

 

 

 

 

 

 

 

 

Common

 

 

 

 

+

-

 

 

 

HEAT

EMERGENCY

BLOWER

SYSTEM

REVERSING

AUX.

PUMP

HEAT

 

FAN

XFMR

 

 

VALVE

HEAT

JANITROL / Goodman

E

G

Y

R

O

W2

C

 

LENOX TYPICAL HP6

 

F

M

V/VR

R

Y

X

 

 

 

 

 

 

 

 

 

 

LENOX HP8

E

F

M

V/VR

R

Y

X

 

 

 

 

 

 

 

 

 

 

LENOX HP9, 10

E

F

M

V/VR

R

Y

X

L

(DHP2120) FRENCH - SCHÉMAS D'IDENTIFICATION DES FILS ET DU CÂBLAGE

LENOX HP16, 18, 19

E

F

M

V/VR

R

Y

 

X

L

 

MAGIC CHEF PE

E

G

Y

R

O

W

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

RHEEM / RUUD

E

G

Y

R

 

W2

B

X

L

 

 

 

 

 

 

 

 

 

 

 

 

SNYDER GENERAL H-R811

 

G

Y

R

O

W1

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANE

X2

G

Y

R

O

W

 

B

F

T

 

 

 

 

 

 

 

 

 

 

 

WEATHERKING

 

G

W1

R

Y1

E

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

WESCO

E

G

W1

R

Y1

W2

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

WESCO / ADDISON

E

G

W1

R

O

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

WESTINGHOUSE H50

E

G

Y

R

O

W

 

X

L1

 

 

 

 

 

 

 

 

 

 

 

 

WESTINGHOUSE HE

 

F

C

V/VR

 

H2

Z

X

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE RODGERS

E

G

Y

R

O

W2

 

C/X1

L

 

 

 

 

 

 

 

 

 

 

 

 

YORK

 

G

Y

R

O

W

 

B

X

 

WIRING DIAGRAM NOTES:

N° 1

LES POMPES À CHALEUR À UN ÉTAGE TYPIQUES DE 24 VOLTS

ET LES SYSTÈMES DE POMPE À CHALEUR À 2 ÉTAGES DE CHALEUR / 1 ÉTAGE DE REFROIDISSEMENT SANS FIL DE CHAUFFAGE D'URGENCE

Y1

E

G

R

B/O

Y2

W2

C

 

 

 

 

 

 

 

** Reportez-vous à la note

 

 

 

 

 

 

 

de câblage numéro 1

 

 

 

 

 

 

 

Système

 

 

 

 

 

 

 

commun

 

 

 

 

+

-

 

 

POMPE À

 

VENTILATEUR

SYSTÈME

ROBINET

AUX.

CHALEUR

 

SOUFFLANT

XFMR

INVERSEUR

CHALEUR

N° 2

LES SYSTÈMES DE POMPES À CHALEUR À

 

UN ÉTAGE DE REFROIDISSEMENT / 2 ÉTAGES DE CHAUFFAGE

 

 

TYPIQUES DE 24 VOLTS AVEC UN FIL DE CHAUFFAGE D'URGENCE

 

Y1

E

G

R B/O Y2 W2 C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Système commun

 

 

 

+

-

 

 

POMPE À

CHAUFFAGE

VENTILATEUR

SYSTÈME

ROBINET

AUX.

CHALEUR

D'URGENCE

SOUFFLANT

 

XFMR

INVERSEUR

CHALEUR

1.The DASHED lines in wiring diagram #1 are optional depending upon your system type. Single stage heat pumps will not have wires present for the “E” or “W2” terminals. For a 2-Heat / 1-Cool system with NO Emergency heat wire, AUX heat will be connected to “W2”. A jumper wire may be placed in between the “E” and “W2” terminals to allow Emergency Heat Mode.

2.For Heat Pumps, use either the “B” or “O” wire, NOT BOTH.

3.If “Y” and “C” wires are both present, then “C” is a common wire. Do not connect this “C” wire to your thermostat.

4.If you have a “B” wire in your system that is used as a common wire, connecting it to the “B/O” terminal on this thermostat may damage your system and/or the thermostat.

(DHP2120) - IDENTIFICACIÓN DE CABLES Y DIAGRAMAS DE CABLEADO

NOTES DU DIAGRAMME DE CÂBLAGE :

1.Les lignes en TRAITS TIRÉS du diagramme de câblage 1 sont optionnelles et leur utilisation dépend de votre type de système. Les pompes à chaleur à un étage n'ont pas de fils pour les bornes « E » ou « W2. » Pour un système à 2 chauffage / 1 refroidissement SANS fil de chauffage d'urgence, la chaleur AUX sera branchée à « W2 ». Un fil de calier peut être placé entre les bornes « E » et « W2 » pour permettre l'utilisation du mode de chau ffage d'urgence.

2.Pour les pompes à chaleur, utilisez soit le fil « B » ou « O », NON PAS LES DEUX.

3.Si vous avez les fils « Y » et « C », alors le « C » est le fil commun du système. Ne branchez pas ce fil « C » à votre thermostat.

4.Si vous avez un fil « B » dans votre système et si ce fil est utilisé comme fil commun, le brancher à la borne « B/O » du thermostat pourrait endommager votre système et/ou le thermostat.

NOTAS DEL DIAGRAMA DEL CABLEADO:

1.Las líneas PUNTEADAS en el diagrama del cableado #1 son opcionales, dependiendo del tipo de sistema. Las bombas de calefacción de una fase no contienen cables para las terminales “E” ni “W2”. Para un sistema de 2 fases de calefacción y una de enfriamiento, NO se conecta el cable de calefacción de emergencia ni el auxiliar (AUX) en la terminal “W2”. Puede colocar un cable para formar un puente entre las terminales “E” y “W2” y permitir un modo de calefacción de emergencia.

2.Para las bombas de calefacción, utilice el cable “B” o el cable “O”, NUNCA USE AMBOS.

3.Si tanto el cable “Y” como el “C” están presentes, entonces es más probable que el “C” sea el cable común del sistema. No conecte el cable “C” a su termostato.

4.Si en su sistema hay un cable “B” que se utiliza como cable común, no lo conecte a la terminal “B” ni “O” del termostato, pues podría dañar tanto su aparato como su sistema.

#1

BOMBAS TÍPICAS DE CALEFACCIÓN DE UNA FASE Y SISTEMAS

TÍPICOS CON BOMBA DE CALEFACCIÓN DE 2 FASES

Y AIRE ACONDICIONADO DE 1 FASE, TODOS DE 24 VOLTIOS

Y1

E

G

R

B/O

Y2

W2

C

 

 

 

 

 

 

 

**Consulte la Nota

 

 

 

 

 

 

 

de cableado #1

 

 

 

 

 

 

 

Sistema

 

 

 

 

 

 

 

Común

 

 

 

+

 

-

 

 

BOMBA DE

 

VENTILADOR

SISTEMA

 

VÁLVULA DE

CALEFACCIÓN

CALEFACCIÓN

 

XFMR

 

INVERSIÓN

AUX.

 

 

 

 

#2 SISTEMAS TÍPICOS CON BOMBA DE CALEFACCIÓN DE 2 FASES Y AIRE ACONDICIONADO DE 1 FASE DE 24 VOLTIOS,

CON CABLE DE CALEFACCIÓN DE EMERGENCIA

 

Y1

E

G

R

B/O

Y2

W2

C

 

 

 

 

 

 

 

 

 

 

Sistema

 

 

 

 

 

 

 

 

 

Común

 

 

 

 

 

+

-

 

 

 

BOMBA DE

CALEFACCIÓN DE

VENTILADOR

SISTEMA

VÁLVULA

 

CALEFACCIÓN

CALEFACCIÓN

EMERGENCIA

XFMR

DE INVERSIÓN

AUX.

 

 

Page 2
Image 2
Lux Products warranty DHP2120 ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS, R B/O Y2 W2 C