Place Base, Figure 3, over Sub-Base and attach by tightening three captive screws.

Fasten loosely to wall using two mounting screws. Place a level against the bottom of the Base, adjust until it is level and then tighten mounting screws to secure.

Find anticipator setting on old thermostat. Setting on new thermostat should be the same. Do this by carefully sliding the long pointer , Figure 2, over desired number printed on the anticipator. If old anticipator setting cannot be determined, look on gas control on furnace, or set at at .6. During heating season, furnace should operate about five times an hour. If adjustments are necessary, move heat

anticipator pointer slightly and recheck.

NOTE: Set pointer to 1.2 for millivolt systems.

Attach front cover, Figure 1, to base.

Turn electricity and gas back on and set pointer on top of thermostat to desired temperature.

FOR HEATING: Set slide switch to “Heat”. Set fan switch to “Auto”.

FOR COOLING: Set slide switch to “Cool”. Set fan switch to “Auto”.

FAN: For continuous blower operation, set switch to “ON”. For automatic blower operation set fan switch to “Auto”. Thermostat will then cycle the blower “on” anf “off”.

A thermostat can only control temperature near it. If you find that it is uncomfortable some distance away from the thermostat, change the setting in order to compensate for this.

FIGURE 1

FRONT COVER

MOUNTING HOLE

 

 

 

 

 

 

 

 

UP

 

 

FIGURE 2

 

 

 

O

.

Y

ANTICIPATOR

 

BASE

 

 

 

ER

 

 

 

 

 

 

15

.

 

 

 

 

 

 

2

.

 

 

 

 

 

 

 

N

G

 

12

 

 

 

 

 

L

 

C

 

 

 

 

.

 

 

E

 

LONG

 

 

 

2

 

 

 

 

 

 

 

5

 

 

 

S

 

 

 

 

 

 

3

 

.5

POINTER

 

 

 

 

 

 

 

 

 

 

 

.

 

.4

 

 

 

 

 

 

 

 

 

 

 

CAPTIVE

 

 

 

 

 

 

 

 

 

SCREW

 

 

CAPTIVE

HOLES FOR WIRES

MOUNTING

 

 

SCREW

HOLE

 

 

 

 

 

 

 

 

 

UP

 

 

 

 

 

 

 

 

UPhoriz

vert

 

FIGURE 3

 

 

O

 

 

 

 

 

 

SUB-BASE

 

RH

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RC

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

Y

W

 

 

 

 

 

 

 

 

FIGURE 4

DECORATIVE

WALL PLATE

TECHNICAL ASSISTANCE

If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance Department at 856- 234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproducts.com. Our web site offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.

WARRANTY

Limited Warranty: If this unit fails because of defects in materials or workmanship within three years of date of original purchase, LUX Products Corporation will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from date of original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which purchase was made, along with proof of purchase. Please refer to "TECHNICAL ASSISTANCE" before returning thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.

RECYCLING

This product does not contain mercury. However, this

 

NOTICE

product may replace a unit which contains mercury and

 

 

 

should not be disposed of in the trash. Contact your local

 

 

 

waste management authority for proper disposal

 

 

 

instructions for mercury in a sealed glass tube.

 

 

 

If you have any questions, please call (856) 234-8803

 

 

 

 

 

 

 

4