Lynx Plus Series Control

Quick Installation Guide

This Quick Installation Guide can help you install the rechargeable Lynx Plus Series Control quickly and easily by providing the basic steps for installation using the built-in defaults and the Voice Prompt Programming mode. The Voice Prompt Programming mode allows you to quickly program the system by responding to a series of voice prompts.

FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech (see Lynx Plus Series Installation and Setup Guide P/N 800-03857 or higher)

WARRANTY INFORMATION

For the latest warranty information, please go to:

www.honeywell.com/security/hsc/resources/wa

1. Install the Control

2. Make Wiring Connections

3. Make Battery Connections

4. Program the Control

MOUNTING

HOOKS

BACK

CASE

WARNING

 

 

 

 

 

 

UL NOTE

 

 

 

TO PREVENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE MINIMUM WIRE SIZE USED FOR TELEPHONE

RISK OF SHOCK,

 

 

 

 

 

 

 

 

 

 

INSTALLATIONS MUST BE #26 GAGE

DISCONNECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TELEPHONE LINE

 

 

 

 

 

ALL OUTPUT CIRCUITS ARE POWER LIMITED.

AT TELECOM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JACK BEFORE

 

 

 

 

 

 

HARD

 

 

 

SERVICING

 

 

 

 

 

 

WIRED

 

 

 

THIS UNIT

 

 

 

 

 

 

ZONE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INCOMING

 

6-14VDC 6-14VDC

 

 

 

 

30mA max.

120mA max.

 

 

 

TELEPHONE

 

 

 

 

 

2k

 

 

 

 

 

 

LINE

 

 

 

 

EARTH

PREMISES

OHMS

 

 

 

 

 

 

 

 

 

 

 

EOLR

 

 

 

GROUND

 

 

 

 

 

TELEPHONE

BELL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIEZO

NOTE

USE ONLY THE

K10145WH/K10145X10

OR K10145CN

TRANSFORMER

PROVIDED

SCREW

RETAINER

BATTERY PACK

NOTE

WALYNXRCHKIT-SHA BATTERY PACK SHOWN

Change the Installer Code

The factory default Installer Code for the Lynx Plus Series Control is set to 4-1-1-2. To change this code, you must enter Expert Programming mode.

1. After Power-up, enter Installer Code + 8 0 0 or press both the []

and [#] simultaneously within 50 seconds after power is applied to

the control. The system will enter the Expert Programming Mode

and “20 INSTALLER CODE” will be displayed.

TELEPHONE

ROTATE

CONNECTION

FRONT CASE

 

 

UPWARD

 

TO RELEASE

PLCD

HOOKS

CONNECTOR

 

 

BATTERY

 

CONNECTIONS

 

GSML/GSMVL

 

COMMUNICATIONS

 

PORT

 

TIP

RING

TIP

RING

 

 

 

 

 

 

8

T

R

T

R

 

HWZ

 

SOUND

AC

AC

 

 

OUT

POS

 

 

 

 

 

 

 

 

 

 

JACK

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

INCOMING

PHONE

LINE

EARTH

PHONE

ZONE

SOUNDERS

AC

GROUND

 

 

 

 

AC

AC

K10145WH/K10145X10

OR K10145CN

PLUG-IN

TRANSFORMER 9VAC, 25VA

Note: Upon power-up or after exiting program mode, the system takes up to a minute to reset. To bypass the reset delay, enter [#]+[0].

2.Enter 20

3.Enter a new four-digit Installer Code.

Program variable data fields

1.

If required, enter 24 to program the desired 2-digit RF House ID

 

for wireless keypads.

2.

If required, enter 40 to program a PABX Access Code or to

 

Disable Call Waiting (LynxSIA Plus only).

 

GSMVL AUDIO

 

CABLE CONNECTOR

 

FRONT

 

CASE

LOCKING TABS

1000-300-011-V0

1.Separate the front case from the rear case by rotating the front case and releasing the hooks from the rear case.

2.Feed the wiring through the openings provided in the rear case.

3.Mount the rear case to a sturdy wall and secure with the provided screws.

3. Reconnect the front case and rear case.

1000-100-004-V0

Note: For the complete Summary of Connections, refer to the Lynx Plus Series Installation and Setup Guide P/N 800-03857 or higher

1.Make earth ground connections to terminal 1.

2.Connect the incoming phone line to either the 8-position jack or terminals 2 (TIP) and 3 (RING).

3.Connect the handset phone lines to terminals 4 (TIP) and 5 (RING).

Note: For full line seize operation, refer to the Lynx Plus Series Installation and Setup Guide.

4.If used, connect a piezo sounder or bell to terminals 8 (-) and 9

(+).

5.Connect the sensors/contacts to the hardwired zone terminals 6 (-) and 7 (+).

6.If used, connect the GSML or GSMVL communications device to the GSML/GSMVL communications port.

7.Connect wires from the K10145WH/K10145 OR K10145CN Transformer to terminals 10 and 11.

Note: If using Powerline Carrier Devices refer to the Lynx Plus Series Installation Guide P/N 800-03857 or higher.

1000-300-007-V0

1.Remove screw securing the battery retainer.

2.Remove the battery retainer.

3.Insert battery pack into back plate.

4.Install battery retainer.

5.Install screw to secure the battery retainer.

6.Connect battery connector to receptacle on PC board.

7.After all wiring connections have been made, snap the front assembly to the back plate so it is held by the locking tabs.

8.Plug the transformer into a 24-hour, 110VAC unswitched outlet.

Note: Rechargeable batteries may take up to 48-hours to fully charge. “LOW BAT” message should clear within four hours, or by entering Test Mode.

3. Enter 94 to program the downloading computer phone number.

4. Press the ESCAPE/ OFF key to enter Voice Prompt Program

mode. The system will announce, “Programming, use arrowsto scroll choices, press select to accept, press escape to quit.” The system will announce the available options.

5.Follow the directions provided by each voice prompt to make your selections.

The FUNCTION/ # key can be used to repeat a voice prompt,

as required.

6.When you have completed each programming procedure the system will return to the Main Programming Menu.

Viewing data fields

1.To view data entered in field, press [#] plus the field that you wish to view (e.g., #21). The system will beep three times and data programmed for that field will be displayed to the right of the field number. The system will scroll through the data for longer numbers and a beep will sound after each number is displayed or three times after the final digit is displayed.

(Continued on reverse side)

Ê800-03860/Š

 

 

 

2 Corporate Center Drive, Suite 100

 

 

 

P.O. Box 9040, Melville, NY 11747

 

 

 

 

800-03860 9/09 Rev. A

 

 

 

Copyright © 2009 Honeywell International Inc.

 

 

 

www.honeywell.com/security

 

 

 

 

Page 1
Image 1
Lynx 1000-300-011-V0 warranty Change the Installer Code, Program variable data fields, Viewing data fields