LT

 

 

 

 

RT

 

AMP

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2

5.The MNCS system may be connected two ways depending on the amplifier used with the system. The major difference is the subwoofer connections.

An amplifier with a subwoofer output connection, usually a RCA type connector would be the preferred connection when used with the MNCS subwoofer (see figure 3). A shielded audio cable is required for this setup with a Y-adaptor connecting the audio cable to left and right “LINE INPUT” on the subwoofer.

CENTER

CENTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT

 

 

 

 

 

 

 

 

 

POWERED

RT FRONT

 

 

 

 

 

 

 

 

LT FRONT

 

 

RT

 

 

SUBWOOFER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMP

 

 

 

 

 

 

LT REAR

RT REAR

Figure 4

6.IMPORTANT! Make sure there are no loose strands of wire touching each other across the speaker or amplifier terminals. This can create a short circuit and damage your electronics.

7.Plug your amplifier or receiver in, turn it on, and enjoy your new music system.

SETTING UP THE SYSTEM

LT FRONT

LT REAR

AMP

Figure 3

RT FRONT

POWERED

SUBWOOFER

RT REAR

Use the settings on the amplifier/receiver for the MNC. If a separate subwoofer is being added, the volume and crossover frequency will need to be set (see notation under MNCS setup).

The MNCS system will require setting up the front, center, and rear speakers as recommended in your amplifier/receiver instruction manual. The subwoofer provided with the system allows setting of the phase, volume, crossover frequency, and an auto power control.

The phase switch is set for the best bass sound. Switch between the 0-

180 position until the bass is loudest. In some applications, there may be

no noticeable difference and in this case leave the switch in the 0

position.

The other option requires the front left and right speaker cables be routed from the amplifier through the subwoofer to the speakers. The wires from the amplifier should be connected to the “HIGH LEVEL INPUT’ and the cables going to the speaker should be connected to the “HIGH LEVEL OUTPUT” on the subwoofer (see figure 4).

4 of 7

The crossover frequency can be set between 40 and 180Hz. It is

 

recommended that the control be set to 180Hz with the mini-cube

 

speakers.

The volume control should be set to the desired bass level for the

 

system.

5 of 7

Page 3
Image 3
M&S Systems MNC / MNCB, MNCS / MNCSB instruction manual Amp, Setting UP the System

MNC / MNCB, MNCS / MNCSB specifications

M&S Systems MNC (Multi-Network Controller) and its variations such as MNCB, MNCS, and MNCSB represent cutting-edge solutions in the realm of network management and control. These systems are designed to handle the complexities of modern communication networks, ensuring efficient operation while providing a robust and scalable architecture.

The primary feature of M&S Systems MNC is its ability to manage multiple network interfaces simultaneously, providing seamless connectivity across various communication channels. This multi-network approach allows organizations to leverage diverse network technologies, enhancing resiliency and performance. The MNC architecture can support both wired and wireless technologies, ensuring compatibility with traditional telecommunication networks and emerging internet-based protocols.

In terms of technology, M&S Systems employs advanced algorithms for traffic management, prioritizing data packets based on real-time analysis of network conditions. This intelligent traffic shaping helps optimize bandwidth usage and minimizes latency, critical for applications that require high reliability and speed, such as video conferencing and real-time data processing.

Another noteworthy characteristic of M&S Systems MNC lies in its secure architecture. With the increasing threats posed by cyberattacks, these systems incorporate robust security protocols to safeguard data transmission. Encryption techniques, secure access controls, and continuous monitoring are integral components that protect sensitive information across multiple networks.

MNC variations like MNCB enable enhanced business continuity through failover solutions. Should one network experience failure, the system can dynamically reroute traffic to maintain service availability. Moreover, MNCS and MNCSB configurations introduce specialized capabilities for service providers, enabling them to manage customer networks efficiently while reducing operational overhead.

Furthermore, M&S Systems solutions are built with a user-friendly interface, allowing network administrators to monitor performance, manage resources, and configure settings with ease. The systems provide comprehensive reporting and analytics, helping organizations make informed decisions based on network performance metrics.

Overall, M&S Systems MNC, MNCB, MNCS, and MNCSB stand out as indispensable tools for modern network management. Their integration of advanced technologies, robust security measures, and user-friendly design positions them as the go-to solutions for organizations looking to enhance their network capabilities and ensure uninterrupted service delivery. As communication demands continue to evolve, these systems are set to become even more crucial in supporting the future of connectivity.