MK2
TECHNICAL INFORMATION
HR624
Enclosure
Materials and Construction:
Open cell adiabatic “foam fill” acoustical damping material absorbs internal reflections, preventing delayed sound coloration.
Transducers
| |
Diameter: | 6.7 inches (170mm) |
Sensitivity (2.83V, 1 m): | 89 dB SPL |
Nominal Impedance: | 4 Ω |
Voice Coil Diameter: | 1.25 inches (32mm) |
Power Handling (Long Term/Program): | |
| 50/150 watts |
Frequency Range: | 45 Hz to 6 kHz |
Frame: | |
Magnet: | Ferrite |
Fully shielded: | Ferrite opposing magnet |
| |
Sensitivity (2.83V, 1m): | 91 dB SPL |
Nominal Impedance: | 6 Ω |
Power Handling (Long Term/Program): | |
| 20/50 watts |
Frequency Range: | 1.6 kHz to 22 kHz |
Diaphragm/Suspension: | Titanium with polymer suspension |
Voice Coil Diameter: | 1.0 inch (25.4mm) |
Magnet: | Neodymium |
Bucking Magnet: | Ferrite opposing magnet |
Passive Radiator:
Crossover Section
Crossover Type:
Modified
Amplifier Section
Rated Power (at 1 kHz with 1% THD):
| 100 watts |
Rated Load Impedance: | 4 ohms |
Rated THD (1W to
| 0.1 % |
Slew Rate: | 15V/µS |
Distortion (THD, SMPTE IMD, DIM 100): < 0.035%
>101 dB
Cooling:Convection
Design: | Monolithic IC, Class AB, |
| Parametric Servo Feedback |
Rated Power(at 1 kHz with 1% THD):
| 40 watts |
Rated Load Impedance: | 6 ohms |
Rated THD (1W to
| 0.1 % |
Slew Rate: | 15V/µS |
Distortion (THD, SMPTE IMD, DIM 100): < 0.035%
(20
>93 dB
Cooling:Convection
Design: | Monolithic IC, |
| Conventional Class AB |
System Specifications
Input Type: | Balanced Differential |
| (XLR and 1/4" TRS) |
| Unbalanced (RCA) |
Input Impedance: | 20 kΩ Balanced |
| 10 kΩ Unbalanced |
Input Protection: | RFI and Level Protected |
Maximum Input Level: | +20 dBu |
Low Frequency Filter: | 80 Hz, 2nd Order, Butterworth |
HF Equalization: | Shelving ±2 dB @ 10 kHz |
Acoustic Space: |
|
A position: | |
B position: | |
C position: | Flat |
Compressor: |
|
Independent high and low frequency overload detection | |
Enclosure Alignment: | 6th Order |
Over Excursion Prevention: | 2nd Order |
Low Line Voltage Shut Down: | 60% of Nominal Line |
Thermal Protection: | Amplifier |
Muting: | 5 seconds at |
Signal Sense Threshold: | |
Driver Protection: | Independent LF and HF Detection |
| Overall Compression |
16 | HR624 MK2 |