POLARITY

0°

180° POLARITY
THX = 0˚

This switch reverses the polarity of the signal going to the subwoofer amplifier by 180º. It has no effect on the signal at the LEFT and RIGHT OUT or the MASTER OUT.

There is no right or wrong setting for this switch. Listen to the overall blend of the subwoofer with the rest of the system, and select the switch position that gives you the best sound.

LEFT AND RIGHT INPUTS

Balanced XLR female and unbalanced RCA female connectors are provided for the left and right inputs. Connect the full-range line-level signal from the mixer or preamplifier to one of these input jacks.

The connectors are wired as follows (per the AES/IEC standard):

 

XLR

RCA

Hot (+)
Pin 2
Tip
Cold (–)

Pin 3

Shield (Ground)

Pin 1

Shield

If connecting a single subwoofer or LFE output to the HRS120, use the LEFT (MONO) input with the FILTER BYPASS switch pushed in.

LEFT AND RIGHT OUTPUTS

Balanced XLR male and unbalanced RCA female connectors are provided for the line-level left and right high-pass outputs. Connect these to the inputs of the main speakers (if they are powered speakers) or to the inputs of the amplifier powering the main speakers.

The signal at the left and right outputs is post-crossover. The low-pass output from the crossover goes to the internal power amplifier in the HRS120, while the high-pass output goes to these output jacks.

CROSSOVER

SUB SAT

80Hz

55Hz 110Hz

CROSSOVER

THX = 80Hz

This adjusts the crossover frequency for the built-in 24 dB/octave Linkwitz-Riley variable crossover. The crossover frequency can be adjusted from 55Hz to 110Hz.

INPUT/OUTPUT

POWER

SUB BYPASSED

 

 

SUBSONIC FILTER

FLAT

THX PM3 SETTINGS

15Hz

 

 

 

SUBSONIC FILTER

 

 

FILTER BYPASS

FILTER IN

 

 

 

FULL RANGE

FILTER BYPASS

 

 

 

VARIABLE

FILTER SELECT

(N/A)

 

FILTER SELECT

 

 

 

110Hz ELLIPTICAL

LFE GAIN

 

 

 

 

 

 

LFE GAIN

0dB

INPUT SENSITIVITY

 

 

 

 

 

+10dB

 

 

 

 

 

POLARITY

 

 

 

NORMAL

 

INPUT SENSITIVITY

 

SUB SAT

 

 

 

 

 

 

 

0°

80Hz

 

 

 

CROSSOVER CONTROLS

 

 

180° POLARITY

 

 

 

OFF NORMAL

 

 

 

 

 

LEFT

 

 

 

IN

(MONO)

 

 

SUB

OUT

 

 

SAT

 

 

80Hz

 

 

 

55Hz

110Hz

 

 

 

CROSSOVER

 

 

 

 

L

L

 

 

 

IN

OUT

 

 

 

R

R

 

 

SUB

SAT

 

 

 

80Hz

 

 

 

55Hz

110Hz

 

 

 

CROSSOVER

OUT

 

 

 

IN

 

 

 

 

RIGHT

 

 

 

SLAVE/MASTER

 

 

SLAVE

MASTER

 

 

 

IN

OUT

 

 

 

S

M

 

 

POLARITY &

 

 

 

INPUT SENSITIVITY ACTIVE

PROCESSED SIGNAL

 

 

 

SUBWOOFER BYPASS

 

 

 

FOOT SWITCH

REMOTE INDICATOR

 

 

OPEN - SUB ON, L/R BASS MANAGED

*MAX OPEN CIRCUIT 24V

 

 

CLOSED - SUB DEFEAT, L/R FULL RANGE

*MAX CLOSED CIRCUIT 1A

 

 

REMOTE INDICATOR CIRCUIT CLOSED WHEN SUB BYPASSED

*TO INSURE PRODUCT SAFETY, POWER SUPPLIES MEETING CLASS-2 INSULATION

REQUIREMENTS SHOULD ONLY BE USED WITH THIS CONNECTOR

9