1/16/97

FAST RECOVERY SERIES HIGH CURRENT POWER AMPLIFIERS

TM

MORE INFORMATION

1.GENERAL. The amplifier shall have a free-standing frame with front and rear brackets for rack-mounting, and supplied with four resil- ient feet suitable for table- top placement. The amplifier shall be capable of two- channel operation, with a switch to place the amplifier into single-channel operation by bridging the outputs of the two channels.

2.POWER OUTPUT.

M•1200: The power ampli- fier, being of two channels, shall deliver 225 watts RMS into 8 ohms per channel, 400 watts into 4 ohms, and 600 watts into 2 ohms with both channels operating. In bridge-mode of operation it shall deliver 800 watts RMS into 8 ohms and 1200 watts into 4 ohms.

M•1400: The power ampli- fier, being of two channels, shall deliver 250 watts RMS into 8 ohms per channel, 425 watts into 4 ohms, and 630 watts into 2 ohms with both channels operating. In bridge-mode of operation it shall deliver 850 watts RMS

into 8 ohms and 1260 watts into 4 ohms.

3.POWER SUPPLIES. All necessary operating voltages for the amplifier shall be pro- vided by an internal power supply. A master power switch shall be located on the front panel along with a green power-indicating light.

4.INPUT CHANNEL CONNECTIONS. Each monaural input channel shall have an electronically balanced line-level input, accommodating a nominal line level between –10dBV and +4dBu, and appearing on the rear panel as a female XLR-3 type connector. In addition, each monaural input channel shall have a parallel 1/4" TRS phone jack and a male XLR-3 type connector, which can be used as inputs or “thru” jacks for daisy-chaining the input signal to another amplifier. Pin 2 of the XLR connectors, and the tip of the 1/4" TRS phone jack, shall be non-inverting.

THESE SPECIFICATIONS ARE AVAILABLE ON 3.5"WINDOWS & MAC DISKSIN POPULAR WORDPROCESSOR FORMATS

CALL 800/258-6883 FAX 425/487-4337OUTSIDE THE U.S., CALL

425/487-4333

FAX 425/485-1152

5.INPUT CHANNEL LEVEL CONTROLS. Each monaural input channel shall be equipped with a gain control appearing on the front panel, each having 40 detent positions, and calibrated in dB and volts.

6.FRONT PANEL INDICA- TORS. Each channel shall have an associated six-seg- ment LED meter appearing on the front panel, capable of displaying signal present, –20dB,–9dB,–6dB,–3dB, and overload. Each channel shall have internal status LEDs appearing on the front panel to indicate activation of protect mode and short- circuit protection. Two tem-

®