SUGGESTED WIRE SIZE VS LENGTH OF WIRE BETWEEN EACH SENSOR & CONTROL PANEL
SIZE | MAXIMUM DISTANCE |
#18 | 500 feet |
#16 | 800 feet |
#14 | 1250 feet |
GENERAL INFORMATION
All equipment manufactured by Macurco is thoroughly tested and calibrated before leaving the factory. There is no need to
LOCATION
Please refer to the attached data sheet titled “Carbon Monoxide System Layouts in Parking Garages”
SS102H & SS102HC-1 GENERAL INFORMATION
The SS102H is partially housed in a plastic case, which mounts on and becomes the cover of, a standard 4SD electrical box (provided by the installer).
The
A low voltage, four conductor, #18 (or larger) cable connects each SS102H, or
SS102H SENSOR OPERATION
The SS102H sensors have two lights: one green and one red. The green light is a pilot light showing the unit is on and operational. When power is first applied to the unit, the green light will be off for 1 1/2 minutes while the sensor goes through a
The red light, which is normally off, is part of a supervisory circuit that monitors critical functions of the unit. A failure in the sensor is shown by a lighted red light, and at the same time a full range (about 4.8 volts) output on terminal A, to actuate relays in the control panel.
The SS102H was factory calibrated, and cannot be
Although the SS102H is usable within a few minutes of being turned on, it will not reach its calibrated level for about 1 week. The SS102H must be continuously powered.