What’s New V2.0
32Zones:
•Now supports 32 zones instead of 16.
•New zone display:
Off = | Viewing zones 1 to 16 |
| Viewing zones 1 to 16, |
On = | and a zone above 16 is open |
| |
Flashing = Viewing zones 17 to 32 |
Press to toggle zone view
New 13.8Vdc, 200mA Auxiliary Output:
•Requires a DC (12Vdc to 18Vdc, 1A) or AC (12Vac to 16Vac, 20VA) power source. If you do not plan to use the auxilary output, an output value of smaller than 12Vdc will be enough.
Power Source | Auxilary Output |
12Vdc | 11Vdc (Appx.) |
15Vdc to 18Vdc | 13.8Vdc |
12Vac | 12Vdc (Appx.) |
16Vac | 13.8Vdc |
Note: When a power failure occurs, the auxiliary output will drop to 7Vdc (backup battery)
Supports up to 4 Wireless Keypads (MG32WK)
•Can be programmed with the Installer Quick Menu by entering Menu 4 (System Setup) followed by Menu 8 (Keypad Profile)
•Assign keypads in sections [243] to [246].
•Set keypad supervision in section [295], options [1] to [4].
•Set Live Display Mode in section [095], option [6].
•Related events in PGM Event Table: Event Group # 47 to 52.
•For more details, refer to the console’s Programming Guide.
Supports up to 2 Wireless Repeater Modules
•Can be programmed with the Installer Quick Menu by entering Menu 4 (System Setup) followed by Menu 9 (Repeater Profile)
•Assign repeater in sections [247] to [248].
•Set repeater supervision in section [296], options [1] and [2].
•Set repeater options in sections [300] to [311].
•Related events in PGM Event Table: Event Group # 53 to 58.
•For more details, refer to the console’s Programming Guide.
Voice Reporting:
•Five telephone numbers can now be contacted by the
•Remote Access mode allows the user to manage the system remotely by telephone. It can now be accessed through voice reporting. When in alarm, the system calls to play the