Burner Performance
CAUTION: Never cover control knobs or surrounding control surface with utensils, towels, or other objects. Never obstruct free air passage past the control knobs. The knob openings have been sized to properly control air entry to the interior of the appliance during operation.
This appliance has no air shutters. Primary air adjustments are unnecessary. The burners are designed to provide optimum aeration for all gases without air
shutters. When operating properly, burners should produce clearly defined, even blue flames. If the flames have yellow tips or are hazy and otherwise appear to have insufficient air, obtain the services of a qualified service technician. Some yellow tipping on LP gas is normal.
Specified input rates are as shown in figures 15 and 16 below.
5 BURNER MODEL (36″ Wide) | 4 BURNER MODEL (30″ Wide) |
FIGURE 15
36″ Cooktop
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
BURNER LOCATION | Hi |
| Lo | |
Right Front | 12,500 | / 10,500 | 1300 / 1300 | |
Right Rear | 9,200 | / | 9,100 | 1300 / 1300 |
Left Front | 9,200 | / | 9,100 | 1300 / 1300 |
Left Rear | 10,500 | / | 9,100 | 1300 / 1300 |
Center | 9,200 | / | 9,100 | 1300 / 1300 |
|
|
|
|
|
FIGURE 16
30″ Cooktop
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
BURNER LOCATION | Hi |
| Lo | |
Right Front | 12,500 | / 10,500 | 1300 / 1300 | |
Right Rear | 9,200 | / | 9,100 | 1300 / 1300 |
Left Front | 9,200 | / | 9,100 | 1300 / 1300 |
Left Rear | 9,200 | / | 9,100 | 1300 / 1300 |
Center | ||||
|
|
|
|
|
High Altitude Notice
The specified gas burner ratings typically apply to elevations up to 2000 feet. For higher altitudes, the rates may need to be reduced to achieve satisfactory operation. A local certified gas servicer will be able to advise if a reduction is necessary.
10