Valve Access
Valve can be accessed in one of two ways:
1. Remove the front panel just below the front of the hearth pan. This is
accomplished by lifting on the panel. To replace the valve access panel line up
the two pins with the holes in the surround bottom and push the panel over the
hearth pan. (Refer Figure 4)
2. Lift the brick with Majestic logo on it (Refer Figure 5)
Figure 4 Figure 5
Gas Line Installation
The gas valve inlet is ½” BSP
internal (female) thread. The
inlet piping connection, sizing
and appliance isolating valve
must be installed in
accordance with AS5601.
The gas inlet piping can be
brought in through the right
side of the appliance. A hole is
provided to allow for the gas
pipe installation and testing of
any gas connection.
Figure 6 : Parts identification
NOTE: Test for leaks after connection. Use a 50/50 solution of liquid soap and
water to test for leaks at gas fittings and joints. Apply soapy water with a
brush only – do not over apply.
NEVER TEST WITH AN OPEN FLAME.
Page 10 of 18