11. TRANSPORTING

11. TRANSPORTING

When transporting the generator, make sure that

the fuel (gasoline) should be drained from the

tank.

■Secure the tank cap thoroughly.WARNING

To prevent fuel spillage due to the vibration and impact, never transport the generator with the fuel (gasoline) filled in the tank.

Secure the tank cap thoroughly.

To avoid the risk of the gasoline flammability, never leave the generator in an area exposed to direct sunlight or high temperatures for a long time.

Keep the fuel (gasoline) in the exclusive gasoline storage tank made by steel when transporting.

(a)Turn the engine switch to the " ■Do not place any heavy objects on the generator. " (STOP) position.

STOP

RUN

CHOKE

(b)Drain the fuel from the tank.

(c)Secure the tank cap and set the cover in position.

TANK CAP COVER

FUEL TANK CAP Fix the generator with rope as necessary.

12.PREPARATION FOR STORAGE (See Fig. 6)CAUTION

Do not place any heavy objects on the generator.

Select and place the generator in the proper position of the transport vehicle so that the generator not be moved or fallen down.

Fix the generator with rope as necessary.

12.PREPARATION FOR STORAGE (See Fig. 6)

The following procedures should be followed prior to storage of your generator for periods of 6 months or longer.

Drain fuel from fuel tank carefully by disconnecting the fuel line.

Gasoline left in the fuel tank will eventually deteriorate making engine-starting difficult.

When draining fuel from the fuel tank, use the hand pomp and set it into the refilling port. (See Fig. 6-q)

Remove the drain screw of the carburetor. (See Fig. 6-w)

q DRAIN SCREW

Change engine oil.

Check for loose bolts and screws, tighten them if necessary.

Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER TO CLEAN GENERATOR !

Pull starter handle until resistance is felt, leaving handle in that position.

Store generator in a well ventilated, low humidity area.