Manitowoc Ice IB-0620, K00177 installation instructions On a Cornelius ABS or ED150 ICE Dispenser

Models: K00177 IB-1020 IB-0620 IB-0820

1 2
Download 2 pages 60.19 Kb
Page 1
Image 1

K00177

IB-0620/0820/1020

ON A CORNELIUS ABS OR ED150 ICE DISPENSER

Installation Instructions

1.Set adapter on top of the dispenser. Be sure to position the adapter with the backside flange tight to the dispenser.

2.Using the slotted holes in the adapter as a template, drill four (4) 9/64” diameter holes at the bottom of the slots. NOTE: Do not drill deeper than 1/4” past the sheet metal. Use a drill stop!

3.Fasten adapter to dispenser using the four (4) #8 screws supplied with the adapter kit.

4.Set the ice machine on top of the adapter. Align holes in ice machine front angle with the rivnuts on the adapter.

5.Secure the ice machine to the adapter with two (2) #8-32 thumbscrews supplied with the ice machine.

6.Set the front bin cover onto the dispenser. The back flange of the bin cover will latch onto the adapter.

7.Rotate retaining arms into position, as shown for normal ice machine operation.

#8-32 Thumbscrew

2 Places

Adapter

LH Retaining Arm

Bin Cover

Cornelius ABS or ED150

Dispenser

#8 Screw

4 Places

RH Retaining Arm

Manitowoc Ice, Inc.

2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA

Page 1
Image 1
Manitowoc Ice IB-0620 installation instructions On a Cornelius ABS or ED150 ICE Dispenser, Installation Instructions