K00018 STACKING KIT
Installation Instructions
1.The K000187 stacking kit is used for stacking an
2.INSTALLATION OF E-1100 ICE MACHINE:
A.See service manual for uncrating and inspection of ice machine.
B.Remove top cover from and side panels from ice machine.
C.Set ice machine carefully and squarely on bin.
D.Position top cover from kit on
E.Add foam tape from kit, as shown in Illustration 1.
3.INSTALLATION OF E-0600 ICE MACHINE:
A.See service manual for uncrating and inspection of ice machine.
B.Remove top cover and side panels from ice machine.
C.Set
D.Use 1/4” diameter holes in bottom rails of
E.Bolt ice machines together with
4.INSTALLATION OF ICE CHUTE:
A.Attach
B.Remove angle “A” from
C.Attach top mounting bracket from kit to top rail of E- 1100 ice machine using existing screw.
D.Reattach angle “A”.
E.Remove the water curtain limit guard from the E- 1100 ice machine.
F.From the top ice machine, carefully bring the ice chute down in place until the weld studs go into the holes in the mounting brackets. Secure with wing nuts provided in kit.
G.Use RTV from kit to seal all seams between the top cover and
H.Check for free movement of water curtains.
I.Reattach all panels.
J.Proceed to ice machine service manuals for electrical and water
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI |
|
Telephone | 8001833 |